The Multifactorial Nature of Polyethylene Wear in Vivo*
THOMAS P. SCHMALZRIED, M.D.,
FREDERICK J. DOREY, PH.D. and
HARRY MCKELLOP, PH.D.
In the 1980s, the focus of the joint-replacement industry was on fixation of the implants, and progress has been made both with devices that are inserted with cement and with those that are inserted without cement. As has always been the case in the history of joint replacement, each advance has unmasked another limitation. More durable fixation allows for more frequent, more intense, and more variable use of the joint, and the indications for the procedure have gradually been expanded to include younger and more active patients. With greater anticipated longevity for both patients and devices, there are justified concerns about long-term skeletal remodeling, but this has not yet been demonstrated to be a widespread clinical problem. The current problem is osteolysis, which most commonly occurs in association with polyethylene wear particles.
The clinical assessment of the performance of a bearing couple has traditionally been based on radiographic studies. With . . . [Full Text of this Article]

CiteULike Connotea Del.icio.us Technorati What's this?
This article has been cited by other articles:

|
 |

|
 |
 
S. M. Kurtz, C. M. Rimnac, W. J. Hozack, J. Turner, M. Marcolongo, V. M. Goldberg, M. J. Kraay, and A. A. Edidin
In Vivo Degradation of Polyethylene Liners After Gamma Sterilization in Air
J. Bone Joint Surg. Am.,
April 1, 2005;
87(4):
815 - 823.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. H. Hopper Jr., A. M. Young, K. F. Orishimo, and C. A. Engh Jr.
Effect of Terminal Sterilization with Gas Plasma or Gamma Radiation on Wear of Polyethylene Liners
J. Bone Joint Surg. Am.,
March 11, 2003;
85(3):
464 - 468.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. L. Barrack and T. P. Schmalzried
Impingement and Rim Wear Associated with Early Osteolysis After a Total Hip Replacement : A Case Report
J. Bone Joint Surg. Am.,
July 9, 2002;
84(7):
1218 - 1220.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. McKellop, F.-w. Shen, B. Lu, P. Campbell, and R. Salovey
Effect of Sterilization Method and Other Modifications on the Wear Resistance of Acetabular Cups Made of Ultra-High Molecular Weight Polyethylene : A Hip-Simulator Study
J. Bone Joint Surg. Am.,
December 1, 2000;
82(12):
1708 - 1708.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
G. LEWIS
Commentary - Design Issues in Clinical Studies of the in Vivo Volumetric Wear Rate of Polyethylene Bearing Components
J. Bone Joint Surg. Am.,
February 1, 2000;
82(2):
281 - 87.
[Full Text]
|
 |
|

|
 |

|
 |
 
B. K. VAUGHN, T. B. DAMERON, T. W. BAUER, Y. MOCHIDA, T. AKISUE, and R. W. EBERLE
Early Osteolysis Following Total Hip Arthroplasty with Use of a Hylamer Liner in Combination with a Modular Ceramic Femoral Head. A Case Report
J. Bone Joint Surg. Am.,
October 1, 1999;
81(10):
1446 - 9.
[Full Text]
|
 |
|

|
 |

|
 |
 
T. P. SCHMALZRIED and J. J. CALLAGHAN
Current Concepts Review - Wear in Total Hip and Knee Replacements
J. Bone Joint Surg. Am.,
January 1, 1999;
81(1):
115 - 136.
[Full Text]
|
 |
|
|