The Journal of Bone and Joint Surgery (American). 2009;91:1664-1670.
doi:10.2106/JBJS.G.00428
© 2009 The Journal of Bone and Joint Surgery, Inc.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME: Take the activity for this article:
CME 3: July, August, September 2009 (publication date October 5, 2009; expi...
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow Rights and Permissions
Google Scholar
Right arrow Articles by Altenburg, A. J.
Right arrow Articles by Johnston, R. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Altenburg, A. J.
Right arrow Articles by Johnston, R. C.
Related Collections
Right arrow Adult Hip
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Facebook   Add to Technorati   Add to Twitter  
What's this?

Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability

Aaron J. Altenburg, MD1, John J. Callaghan, MD1, Tameem M. Yehyawi, BS1, Douglas R. Pedersen, PhD1, Steve S. Liu, MD1, Jessica A. Leinen, BS1, Kevin A. Dahl, MD1, Devon D. Goetz, MD2, Thomas D. Brown, PhD1 and Richard C. Johnston, MD1

1 Department of Orthopaedics and Rehabilitation, University of Iowa Health Care, 200 Hawkins Drive, Iowa City, IA 52242. E-mail address for J.J. Callaghan: john-callaghan{at}uiowa.edu
2 Des Moines Orthopaedic Surgeons, 6001 Westown Parkway, West Des Moines, IA 50266

Investigation performed at the University of Iowa, Iowa City, and Des Moines Orthopaedic Surgeons, West Des Moines, Iowa

Disclosure: In support of their research for or preparation of this work, one or more of the authors received, in any one year, outside funding or grants in excess of $10,000 from the National Institutes of Health and DePuy. In addition, one or more of the authors or a member of his or her immediate family received, in any one year, payments (royalties) or other benefits in excess of $10,000 or a commitment or agreement to provide such benefits from commercial entities (royalties from DePuy and Zimmer). Also, a commercial entity (DePuy) paid or directed in any one year, or agreed to pay or direct, benefits in excess of $10,000 to a research fund, foundation, division, center, clinical practice, or other charitable or nonprofit organization with which one or more of the authors, or a member of his or her immediate family, is affiliated or associated.


Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used.

Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs.

Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and 83% ± 7% for the cable and wire groups, respectively, at twenty years (p = 0.03).

Conclusions: Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal.

Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Facebook Facebook   Add to Technorati Technorati   Add to Twitter Twitter    What's this?