The Journal of Bone and Joint Surgery (American). 2009;91:1050-1054.
doi:10.2106/JBJS.H.00460
© 2009 The Journal of Bone and Joint Surgery, Inc.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME: Take the activity for this article:
CME 2: April, May, June 2009 (publication date July 6, 2009; expiration dat...
Right arrow [Supplementary Material]
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow Rights and Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mansour, A. A.
Right arrow Articles by Halpern, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mansour, A. A., III
Right arrow Articles by Halpern, J. L.
Related Collections
Right arrow Adult Trauma
Right arrow Basic Science
Right arrow Spine
Right arrow Adult Hip
Right arrow Adult Knee
Right arrow Foot/Ankle
Right arrow Shoulder
Right arrow Elbow
Right arrow Hand/Wrist
Right arrow Sports
Right arrow Pediatrics
Right arrow Oncology
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Facebook   Add to Technorati   Add to Twitter  
What's this?

Eye Protection in Orthopaedic Surgery

An in Vitro Study of Various Forms of Eye Protection and Their Effectiveness

Alfred A. Mansour, III, MD1, Jesse L. Even, MD1, Sharon Phillips, MSPH2 and Jennifer L. Halpern, MD1

1 Vanderbilt Orthopaedic Institute, 1215 21st Avenue South, MEC, South Tower, Suite 4200, Nashville, TN 37232-8774. E-mail address for A.A. Mansour: alfred.mansour{at}vanderbilt.edu
2 Vanderbilt University Medical Center, 1161 21st Avenue South, S-2323 MCN, Nashville, TN 37232-2158

Investigation performed at the Vanderbilt University Medical Center, Nashville, Tennessee

Disclosure: The authors did not receive any outside funding or grants in support of their research for or preparation of this work. Neither they nor a member of their immediate families received payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity. No commercial entity paid or directed, or agreed to pay or direct, any benefits to any research fund, foundation, division, center, clinical practice, or other charitable or nonprofit organization with which the authors, or a member of their immediate families, are affiliated or associated.

A commentary is available with the electronic versions of this article, on our web site (www.jbjs.org) and on our quarterly CD-ROM/DVD (call our subscription department, at 781-449-9780, to order the CD-ROM or DVD).


Background: Conjunctival contamination from splashed debris during orthopaedic surgical procedures places surgeons at risk for communicable diseases such as human immunodeficiency virus (HIV) and hepatitis B and C. The purpose of this study was to compare the effectiveness of various types of protective eyewear in preventing conjunctival contamination.

Methods: A simulation model was constructed with use of a mannequin head in a typical position of a surgeon's head during an operation. The head was placed at an appropriate distance from the surgical field, and a femoral osteotomy was performed on a cadaver thigh. Six experimental groups were tested to determine the ability of various types of eye protection to prevent contamination of the conjunctiva: (1) modern prescription glasses, (2) standard surgical telescopic loupes, (3) hard plastic contoured glasses, (4) disposable plastic glasses, (5) a combination facemask and eye shield, and (6) no protection (control). Thirty femoral osteotomies were performed, and contamination of both the protective devices and the simulated conjunctival surfaces were recorded.

Results: None of the tested devices were completely effective. The modern prescription glasses and the controls both were associated with conjunctival contamination rates of 83%. The other eye protective devices were associated with significantly lower rates of overall contamination, with a rate of 50% for the loupes, 30% for the facemask and eye shield, 17% for the hard plastic glasses, and 3% for the disposable plastic glasses.

Conclusions: Modern prescription glasses provided no benefit over the control in our experimental model; therefore, we do not recommend that they be used as the sole eye protection, especially during surgical procedures in which there is a high rate of debris expulsion from the wound. Readily available and disposable plastic glasses were associated with the lowest rate of conjunctival contamination (3%) and are an effective means with which to protect the orthopaedic surgeon from communicable diseases by conjunctival contamination.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Facebook Facebook   Add to Technorati Technorati   Add to Twitter Twitter    What's this?