The Journal of Bone and Joint Surgery (American). 2006;88:116-125.
doi:10.2106/JBJS.F.00775
© 2006 The Journal of Bone and Joint Surgery, Inc.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow [Supplementary Material]
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seyler, T. M.
Right arrow Articles by Kester, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seyler, T. M.
Right arrow Articles by Kester, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

Use of an Alumina-on-Alumina Bearing System in Total Hip Arthroplasty for Osteonecrosis of the Hip

Thorsten M. Seyler, MD, Peter M. Bonutti, MD, Jianhua Shen, MS, Marybeth Naughton, BS and Mark Kester, PhD

Corresponding author:
Thorsten M. Seyler, MD
Center for Joint Preservation and Reconstruction, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215.
E-mail address: arthrodiastasis{at}hotmail.com.

In support of their research for or preparation of this manuscript, one or more of the authors received grants or outside funding from Stryker Orthopaedics. In addition, one or more of the authors received payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity (Stryker Orthopaedics). No commercial entity paid or directed, or agreed to pay or direct, any benefits to any research fund, foundation, educational institution, or other charitable or nonprofit organization with which the authors are affiliated or associated.


Background: The results of total hip arthroplasty in patients with osteonecrosis of the femoral head are not always optimal. The use of alumina-on-alumina interfaces in young and active patients may decrease wear and lower the rate of aseptic loosening of the implant and appears to be an attractive alternative to the use of conventional cobalt-chromium-on-polyethylene bearings. The purpose of this study was to evaluate the safety and efficacy of the alumina-on-alumina bearing in patients with osteonecrosis and to compare this group of patients to a group of similarly treated patients with osteoarthritis and a group of patients who received conventional cobalt-chromium-on-polyethylene bearings.

Methods: Patients were selected from a United States Investigational Device Exemption multicenter prospective randomized clinical study that was initiated in 1996. Seventy patients with osteonecrosis of the femoral head (seventy-nine hips) received a cementless alumina-on-alumina bearing system and were directly matched to seventy-six patients with osteoarthritis of the hip (seventy-nine hips) who were managed with the same implant. Both groups were compared with twenty-five patients (twenty-six hips) with osteonecrosis and twenty-five patients (twenty-six hips) with osteoarthritis who were managed with a cementless cobalt-chromium-on-polyethylene bearing system. All patients received a cementless hydroxyapatite-coated femoral stem and were followed both clinically and radiographically.

Results: The clinical outcomes for alumina-on-alumina bearings were similar for both osteonecrotic and osteoarthritic hips. The seven-year survival probability was 95.5% for the osteonecrotic hips and 89.4% for the osteoarthritic hips in the alumina-on-alumina bearing group and 92.3% for the osteonecrotic hips and 92.9% for the osteoarthritic hips in the cobalt-chromium-on-polyethylene bearing group. At the time of the most recent follow-up, the mean Harris hip score was 96 points for both the osteonecrotic and the osteoarthritic hips in the alumina-on-alumina group and 96 points for the osteonecrotic hips and 97 points for the osteoarthritic hips in the cobalt-chromium-on-polyethylene bearing group.

Conclusions: The results of the use of alumina-on-alumina and cobalt-chromium-on-polyethylene bearings in cementless standard total hip implants in patients with osteonecrosis and osteoarthritis were comparable. The low revision rate for the alumina-on-alumina bearing is encouraging and offers a promising option for younger, more active patients who have this challenging disease.

Level of Evidence: Therapeutic Level III. See Instructions to Authors on jbjs.org for a complete description of levels of evidence.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
S.-H. Baek and S.-Y. Kim
Cementless Total Hip Arthroplasty with Alumina Bearings in Patients Younger Than Fifty with Femoral Head Osteonecrosis
J. Bone Joint Surg. Am., June 1, 2008; 90(6): 1314 - 1320.
[Abstract] [Full Text] [PDF]