This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow CME: Take the exams for this article:
Shoulder/Elbow Test 4: The Elbow: Arthroplasty, Trauma
CME 2: April, May, June 2004
Right arrow An erratum has been published
Right arrow Letters to the Editor: Submit a response
Right arrow Letters to the Editor: View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Related articles in JBJS
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Markolf, K. L.
Right arrow Articles by Benhaim, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Markolf, K. L.
Right arrow Articles by Benhaim, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery (American) 86:1023-1030 (2004)
© 2004 The Journal of Bone and Joint Surgery, Inc.

Load-Sharing at the Wrist Following Radial Head Replacement with a Metal Implant

A Cadaveric Study

Keith L. Markolf, PhD1, Samir G. Tejwani, MD1, Geoffery O'Neil, BS1 and Prosper Benhaim, MD1

1 Biomechanics Research Section, Department of Orthopaedic Surgery, David Geffen School of Medicine at University of California at Los Angeles, Rehabilitation Building, 1000 Veteran Avenue, Room 21-67, Los Angeles, CA 90095. E-mail address for K.L. Markolf: kmarkolf{at}mednet.ucla.edu

Investigation performed at the Biomechanics Research Section, Department of Orthopaedic Surgery, David Geffen School of Medicine at University of California at Los Angeles, Los Angeles, California

In support of their research or preparation of this manuscript, one or more of the authors received Grant R01 AR43735 from the National Institute of Arthritis and Musculoskeletal and Skin Diseases/National Institutes of Health. None of the authors received payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity. No commercial entity paid or directed, or agreed to pay or direct, any benefits to any research fund, foundation, educational institution, or other charitable or nonprofit organization with which the authors are affiliated or associated.


Background: Surgical excision of the radial head is frequently required after a comminuted fracture of the radial head. The outcome of this procedure is often unpredictable, with some patients experiencing ulna-sided pain in the wrist secondary to proximal migration of the radius. Insertion of a radial head prosthesis could prevent proximal radial migration and restore normal load-sharing at the wrist. The thickness of the radial head implant is an important variable in restoring anatomical radial length; however, the effects of varying the length of implants that were used to reconstruct the radius on load-sharing at the wrist have not been studied biomechanically, to our knowledge.

Methods: A miniature load cell was attached to fifteen fresh-frozen cadaveric forearms to record force in the distal part of the ulna as the wrist was axially loaded to 134 N of compression force. Proximal displacement of the radius relative to the capitellum was also recorded. Loading tests on intact forearms were performed with the elbow in valgus and varus alignment and with three positions of wrist rotation (neutral, 45° of pronation, and 45° of supination). Loading tests were then repeated, with the same positions of varus and valgus elbow alignment and wrist rotation as had been used in the tests of the intact forearm, after radial head excision and subsequent insertion of metal radial head implants that restored anatomical length, implants that produced a radial length that was longer than the anatomical length, and implants that produced a radial length that was shorter than the anatomical length. Testing of these different implant thicknesses was repeated after sectioning of the interosseous membrane.

Results: The mean distal ulnar forces and mean proximal radial displacements following insertion of an implant that restored anatomical length were not significantly different from the corresponding values for the intact forearm. At neutral wrist rotation, replacing that implant with an implant that increased the radial length by 4 mm (after sectioning of the interosseous membrane) decreased the mean distal ulnar force from 13.4% to 3.3% of the applied wrist force with the elbow in valgus alignment and from 29.1% to 8.6% with the elbow in varus alignment. Replacing the implant that restored anatomical length with one that decreased the length by 4 mm (after sectioning of the interosseous membrane) significantly increased the mean distal ulnar force from 13.4% of the applied wrist load to 33.3% with the elbow in valgus alignment and from 29.1% to 51.6% with it in varus alignment. The mean distal ulnar forces were not significantly affected by the position of wrist rotation when the elbow was in valgus alignment. However, when the elbow was in varus alignment, the mean distal ulnar forces associated with all reconstructed radial lengths were significantly higher when the wrist was placed in 45° of supination.

Conclusions: In this cadaveric model, insertion of a metal implant maintained distal ulnar forces at normal levels, at all three positions of wrist rotation, when the radius had been restored to its original anatomical length. Distal ulnar forces and proximal radial displacements were significantly affected by the reconstructed length of the radius.

Clinical Relevance: Radial head implants are utilized to prevent proximal migration of the radius as the wrist is loaded; this is especially important when the interosseous membrane has been ruptured and thus cannot help to limit radial displacement. At the time of surgery, comminution and displacement of a radial head fracture may make estimation of the original radial length difficult. Our results demonstrate that, in terms of distal ulnar loading, it is preferable to insert an implant that is too thick rather than too thin.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?

Related articles in JBJS:

Load-Sharing at the Wrist Following Radial Head Replacement with a Metal Implant. A Cadaveric Study K.L. Markolf replies:
David Ring and Keith L. Markolf
JBJS 2004 86: 2569-2570. [Extract] [Full Text]  



This article has been cited by other articles:


Home page
J Am Acad Orthop SurgHome page
N. C. Tejwani and H. Mehta
Fractures of the Radial Head and Neck: Current Concepts in Management
J. Am. Acad. Ortho. Surg., July 1, 2007; 15(7): 380 - 387.
[Abstract] [Full Text] [PDF]

Letters to the Editor:

Read all Letters to the Editor

Do Not Use the Largest Radial Head Possible
David Ring
JBJS Online, 17 May 2004 [Full text]
Dr. Markolf responds:
Keith L Markolf
JBJS Online, 1 Jun 2004 [Full text]