This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow [Supplementary Material]
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow Rights and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Honl, M.
Right arrow Articles by Morlock, M. M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Honl, M.
Right arrow Articles by Morlock, M. M
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Facebook   Add to Technorati   Add to Twitter  
What's this?
The Journal of Bone and Joint Surgery (American) 85:1470-1478 (2003)
© 2003 The Journal of Bone and Joint Surgery, Inc.


Scientific Article

Comparison of Robotic-Assisted and Manual Implantation of a Primary Total Hip Replacement

A Prospective Study

Matthias Honl, MD, Oliver Dierk, MD, Christian Gauck, MD, Volker Carrero, MD, Frank Lampe, MD, Sebastian Dries, MD, Markus Quante, MD, Karsten Schwieger, PhD, Ekkehard Hille, MD and Michael M Morlock, PhD

Investigation performed at the Department of Orthopaedic Surgery, Barmbek General Hospital, Hamburg, Germany

Matthias Honl, MD
Oliver Dierk, MD
Christian Gauck, MD
Volker Carrero, MD
Frank Lampe, MD
Sebastian Dries, MD
Markus Quante, MD
Ekkehard Hille, MD
Department of Orthopaedic Surgery, Barmbek General Hospital, Ruebenkamp 148, D-22307 Hamburg, Germany. E-mail address for M. Honl: honl{at}ortho-hamburg.de

Karsten Schwieger, PhD
Michael M. Morlock, PhD
Biomechanics Section, Technical University Hamburg-Harburg, Denickestrasse 15, D-21079 Hamburg, Germany

The authors did not receive grants or outside funding in support of their research or preparation of this manuscript. They did not receive payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity. No commercial entity paid or directed, or agreed to pay or direct, any benefits to any research fund, foundation, educational institution, or other charitable or nonprofit organization with which the authors are affiliated or associated.

Background: Robotic-assisted total hip replacement has become a common method of implantation, especially in Europe. It frequently has been postulated that robotic reaming would result in an improved clinical outcome due to the better fit of the prosthesis, but that has never been demonstrated in a prospective study, to our knowledge. The purpose of this study was to compare robotic-assisted implantation of a total hip replacement with conventional manual implantation.

Methods: One hundred and fifty-four patients scheduled for total hip replacement were randomly assigned to undergo either conventional manual implantation of an S-ROM prosthesis (eighty patients) or robotic-assisted implantation of such a prosthesis (seventy-four patients). The five-axis ROBODOC was used for the robotic-assisted procedures. Preoperatively as well as at three, six, twelve, and twenty-four months after surgery, the scores according to the Harris and Merle d'Aubigné systems and the Mayo clinical score were determined. Radiographs made at these intervals were analyzed for evidence of loosening, prosthetic alignment, and heterotopic ossification.

Results: Thirteen (18%) of the seventy-four attempted robotic implantations had to be converted to manual implantations as a result of failure of the system. The duration of the robotic procedures was longer than that of the manual procedures (mean and standard deviation,107.1 ± 29.1 compared with 82.4 ± 23.4 minutes, p < 0.001). Limb-length equality (mean discrepancy, 0.18 ± 0.30 compared with 0.96 ± 0.93 cm, p < 0.001) and varus-valgus orientation of the stem (mean angle between the femur and the shaft of the prosthesis, 0.34° ± 0.67° compared with 0.84° ± 1.23°, p < 0.001) were better after the robotic procedures. At six months, slightly more heterotopic ossification was seen in the group treated with robotic implantation. The group treated with robotic implantation had a better Mayo clinical score at six and twelve months and a better Harris score at twelve months; however, by twenty-four months, no difference was found between the groups with regard to any of the three scores. Dislocation was more frequent in the group treated with robotic implantation: it occurred in eleven of the sixty-one patients in that group compared with three of eighty in the other group (p < 0.001). Recurrent dislocation and pronounced limping were indications for revision surgery in eight of the sixty-one patients treated with robotic implantation compared with none of the seventy-eight (excluding two with revision for infection) treated with manual insertion (p < 0.001). Rupture of the gluteus medius tendon was observed during all of the revision operations.

Conclusions: The robotic-assisted technology had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure. Disadvantages were the high revision rate; the amount of muscle damage, which we believe was responsible for the higher dislocation rate; and the longer duration of surgery. This technology must be further developed before its widespread usage can be justified.

Level of Evidence: Therapeutic study, Level I-1a (randomized controlled trial [significant difference]). See Instructions to Authors for a complete description of levels of evidence.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Facebook Facebook   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
M. Easley, B. Chuckpaiwong, N. Cooperman, R. Schuh, T. Ogut, I. L.D. Le, and J. Reach
Computer-Assisted Surgery for Subtalar Arthrodesis. A Study in Cadavers
J. Bone Joint Surg. Am., August 1, 2008; 90(8): 1628 - 1636.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
K. Bauwens, G. Matthes, M. Wich, F. Gebhard, B. Hanson, A. Ekkernkamp, and D. Stengel
Navigated Total Knee Replacement. A Meta-Analysis
J. Bone Joint Surg. Am., February 1, 2007; 89(2): 261 - 269.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
C. R. Clark, H. D. Huddleston, E. P. Schoch III, and B. J. Thomas
Leg-Length Discrepancy After Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2006; 14(1): 38 - 45.
[Abstract] [Full Text] [PDF]


Home page
SURG INNOVHome page
A. Adili
Robot-Assisted Orthopedic Surgery
Surgical Innovation, June 1, 2004; 11(2): 89 - 98.
[Abstract] [PDF]