The Journal of Bone and Joint Surgery (American) 83:S92-S98 (2001)
© 2001 The Journal of Bone and Joint Surgery, Inc.
Delivery Systems for the BMPs |
Biodegradable Poly-d,l-Lactic Acid-Polyethylene Glycol Block Copolymers as a BMP Delivery System for Inducing Bone
Naoto Saito, MD, PhD,
Takao Okada, MS,
Hiroshi Horiuchi, MD,
Narumichi Murakami, MD,
Jun Takahashi, MD,
Masashi Nawata, MD,
Hiroshi Ota, MD,
Shimpei Miyamoto, MD, PhD,
Kazutoshi Nozaki, PhD and
Kunio Takaoka, MD, PhD
Investigation performed at the Department of Orthopaedic
Surgery, Shinshu University School of Medicine, Matsumoto, Japan
Naoto Saito, MD, PhD
Hiroshi Horiuchi, MD
Narumichi Murakami, MD
Jun Takahashi, MD
Masashi Nawata, MD
Hiroshi Ota, MD
Kunio Takaoka, MD, PhD
Department of Orthopaedic Surgery, Shinshu University School
of Medicine, Asahi 3-1-1, Matsumoto, 390-8621, Japan. E-mail address
for N. Saito: saitoko{at}hsp.md.shinshu-u.ac.jp
Takao Okada, MS
Research Institute, Taki Chemical Co., Ltd., 64-1 Nishiwaki,
Befucho, Kakogawa, Hyogo 675-0125, Japan
Shimpei Miyamoto, MD, PhD
Department of Orthopaedic Surgery, Osaka University Medical School,
2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
Kazutoshi Nozaki, PhD
Applied Pharmacology Laboratories, Institute for Drug Discovery
Research, Yamanouch Pharmaceutical Co., Ltd., 21 Miyukigaoka, Tsukuba,
Ibaraki 305-8585, Japan
In support of their research or preparation of this manuscript,
one or more of the authors received grants or outside funding from
a Grant-in-Aid for Scientific Research from the Ministry of Education, Science,
Sports and Culture, Japan, a Grant from Japan Rheumatism Foundation,
and a Grant from Hip Joint Foundation of Japan. None of the authors received
payments or other benefits or a commitment or agreement to provide
such benefits from a commercial entity. No commercial entity paid
or directed, or agreed to pay or direct, any benefits to any research
fund, foundation, educational institution, or other charitable or
nonprofit organization with which the authors are affiliated or
associated.
Background: Bone morphogenetic proteins (BMPs)
are biologically active molecules capable of eliciting new bone
formation. In combination with biomaterials, these proteins can
be used in a clinical setting as bone-graft substitutes to promote
bone repair. Collagen from animal sources has previously been the preferred
carrier material in animal experiments. More recently, synthetic
biodegradable polymers have been tested as a delivery vehicle for
osteoinductive agents. In earlier studies performed in our laboratory,
it was found that the polylactic acid homopolymers (PLA650) and
poly-d,l-lactic acid-polyethylene glycol block copolymers (PLA650-PEG200)
are viscous liquids that can be used as BMP delivery systems.
Methods: To obtain new PLA-PEG polymers that exhibit greater
plasticity, the molecular sizes of PLA and PEG segments in the copolymer
chains were increased. Plastic PLA-PEG polymers with various molecular
sizes and PLA/PEG ratios were synthesized, mixed with recombinant
human (rh) BMP-2, and implanted into the dorsal muscles of mice
for 3 weeks to evaluate their capacity to elicit new bone formation.
To compare the plastic PLA-PEG polymer with the liquid PLA650-PEG200
polymer, these two polymers were combined with rhBMP-2, implanted,
and harvested after 3 weeks. Bone mineral content (BMC), bone area,
and bone mineral density (BMD) of the ectopic new bone were measured
by means of single energy X-ray absorptiometry (SXA).
Results: All of the PLA6,500-PEG3,000 implants with
10 or 20 g of rhBMP-2 showed new bone formation. In contrast, little
or no bone formation was seen in other plastic PLA-PEG implants
with rhBMP-2. Control implants that lacked rhBMP-2 did not show new
bone formation. Radiographic and histologic examinations showed
that the PLA6,500-PEG3,000 implants with rhBMP-2 harvested 3 weeks
after implantation had normal bone characteristics with hematopoietic
marrow and osseous trabeculae. SXA analysis showed that the values
for bone mineral content (BMC), bone area, and bone mineral density
(BMD) of new bone resulting from the use of plastic PLA6,500-PEG3,000
polymers with rhBMP-2 were significantly higher than those obtained
with the liquid PLA650-PEG200 polymers (p < 0.001 for each
of the three values).
Conclusions: These results indicate that the PLA6,500-PEG3000 block
copolymer with plastic properties works effectively as a BMP delivery
system. These data suggest that the total molecular size and ratio
of PLA size to PEG size is an essential factor in determining the
efficacy of a BMP delivery system. After implantation, it is possible
that the PLA6,500-PEG3,000 pellets might have absorbed tissue fluids
and become swollen, resulting in bone formation that exceeded the
size of the original implants. This expansion characteristic is
a potentially beneficial property, given the intended practical
application of the polymer in the repair of bone defects.
Clinical Relevance:
New synthetic biodegradable delivery systems will play an important
role in the clinical applications of rhBMPs in which local formation
of bone via an osteoinductive graft material is needed. Further
pre-clinical and clinical work is necessary to establish the safety
of these implants before they are adopted for widespread clinical
use.

CiteULike Connotea Del.icio.us Facebook Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
H. Yoshikawa, N. Tamai, T. Murase, and A. Myoui
Interconnected porous hydroxyapatite ceramics for bone tissue engineering
J R Soc Interface,
June 6, 2009;
6(Suppl_3):
S341 - S348.
[Abstract]
[Full Text]
[PDF]
|
 |
|
Letters to the Editor:
Read all Letters to the Editor
- Novel Bone Methodologies: The Biomimetic Implant
- Benjamin W. Kenny, et al.
- JBJS Online, 19 Mar 2009
[Full text]
|