This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow [Supplementary Material]
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Raab, G. E.
Right arrow Articles by Dai, Q. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Raab, G. E.
Right arrow Articles by Dai, Q. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 83:46 (2001)
© 2001 The Journal of Bone and Joint Surgery, Inc.

Damage to Cobalt-Chromium Surfaces During Arthroscopy of Total Knee Replacements

Gregory E. Raab, BS, Christopher M. Jobe, MD, Paul A. Williams, MS and Qiang G. Dai, PhD

Investigation performed at the Department of Orthopaedic Surgery, Loma Linda University School of Medicine, Loma Linda, California
Gregory E. Raab, BS Christopher M. Jobe, MD Paul A. Williams, MS Qiang G. Dai, PhD Department of Orthopaedic Surgery, Loma Linda University School of Medicine, Loma Linda, California 92354
One or more of the authors has received or will receive benefits for personal or professional use from a commercial party related directly or indirectly to the subject of this article. Funds were received in total or partial support of the research or clinical study presented in this article. The funding source was The MacPherson Society of Loma Linda University School of Medicine.
A commentary is available with the electronic versions of this article, on our web site (www.jbjs.org) and on our CD-ROM (call 781-449-9780, ext. 140, to order).

Background: It has been stated that care must be taken not to scratch the metal components during total knee arthroscopy; however, this concern has not been studied. Clinical observation during arthroscopy of total knee replacements suggested the possibility of damage to the femoral component by the arthroscopic cannula; therefore, a bench test was performed to study this potential risk.

Methods: Cobalt-chromium femoral components were tested to determine the surface damage that resulted from moving a stainless-steel arthroscopic cannula and a plastic arthroscopic cannula across the components under a variety of applied loads. Scanning electron microscopy and surface-roughness measurements of the prosthetic surface were used to evaluate the damage.

Results: The stainless-steel cannula produced observable alterations to the surface of the femoral component at loads as small as 8 N. The majority of these alterations were deposits of stainless steel from the cannula onto the component. The plastic cannula did not appear to produce alterations on the component surface. Surface roughness increased with increasing loading of the stainless-steel cannula, but there was no noticeable change with increasing loading of the plastic cannula. These forces did, however, severely damage some parts of the plastic cannula.

Conclusions: Alterations to the surface of cobalt-chromium femoral components can occur during arthroscopy with stainless-steel cannulae but not with plastic cannulae. The results of this study support a recommendation to use plastic cannulae during arthroscopy of total knee replacements.

Clinical Relevance: Arthroscopy of total knee replacements is increasing in the clinical setting, and damage to the prosthesis should be avoided whenever possible. This study provides evidence that damage to the femoral component is possible with a stainless-steel cannula and that use of a plastic cannula may reduce this risk.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
S. W. O'Driscoll, R. S. Petrie, and M. E. Torchia
Arthroscopic Removal of the Glenoid Component for Failed Total Shoulder Arthroplasty. A Report of Five Cases
J. Bone Joint Surg. Am., April 1, 2005; 87(4): 858 - 863.
[Full Text] [PDF]