This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Engh, G. A.
Right arrow Articles by Pereles, T. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Engh, G. A.
Right arrow Articles by Pereles, T. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 82:516 (2000)
© 2000 The Journal of Bone and Joint Surgery, Inc.

Clinical Results of Modular Polyethylene Insert Exchange with Retention of Total Knee Arthroplasty Components*

Gerard A. Engh, M.D.{dagger}, Lisa M. Koralewicz, M.P.H.{dagger} and Thomas R. Pereles, M.D.{ddagger}

Investigation performed at Anderson Orthopaedic Research Institute, Alexandria, Virginia
*No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study.
{dagger}Anderson Orthopaedic Research Institute, P.O. Box 7088, Alexandria, Virginia 22307.
{ddagger}Augusta Medical Center, Suite 110, 93 Medical Center Drive, Fishersville, Virginia 22939.

Background: Modular polyethylene inserts have enabled surgeons to perform an isolated tibial insert exchange while retaining well fixed components. The purpose of this study was to review the results of insert revision and to clarify the role of this option compared with that of revision total knee arthroplasty.

Methods: Fifty-six patients (sixty-three knees) were managed with revision of a tibial polyethylene insert and retention of well aligned and stable femoral and tibial components. The implants had been in situ for an average of fifty-nine months (range, two to 108 months) at the time of the insert exchange. The inserts that were removed at the time of exchange were evaluated with regard to wear of the articular surface according to the classification system of Hood et al. and with regard to undersurface wear according to the method described by Wasielewski et al. Forty-eight knees were followed for an average of 7.4 years (range, 3.0 to 12.2 years) after the insert exchange. Knees that did not require an additional operation were considered to have had a successful exchange.

Results: Seven of the forty-eight exchanges failed, at an average of fifty-four months, because of accelerated wear of the new insert. All seven knees required complete revision of all components. Of the twenty-two exchanges that were performed because of severe wear of the primary insert, six (27 percent) failed at an average of less than five years; thus, knees in which the exchange was performed because of advanced wear were more likely to fail again (p < 0.05). In addition, primary inserts that were removed from knees in which the exchange procedure subsequently failed had higher delamination scores than those that were removed from knees in which the exchange was successful (p < 0.05). Most of the primary inserts had substantial undersurface wear at the time of the exchange procedure. Metallosis (thirty knees) and osteolysis (nineteen knees) were unrelated to failure of the exchange.

Conclusions: An isolated revision of the tibial polyethylene insert should not be performed when there is accelerated wear of the insert with severe delamination and grade-3 or 4 undersurface wear within ten years after the primary procedure. Because a variety of patient-related, implant-related, and technical factors influence polyethylene wear, the orthopaedist must consider multiple variables whenever contemplating a limited revision.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
E. Jamsen, H. Huhtala, T. Puolakka, and T. Moilanen
Risk Factors for Infection After Knee Arthroplasty. A Register-Based Analysis of 43,149 Cases
J. Bone Joint Surg. Am., January 1, 2009; 91(1): 38 - 47.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
W. Maloney and A. Rosenberg
What is the outcome of treatment for osteolysis?
J. Am. Acad. Ortho. Surg., July 1, 2008; 16(suppl_1): S26 - S32.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
S. Patil, D. D. D'Lima, J. M. Fait, and C. W. Colwell Jr.
Improving Tibial Component Coronal Alignment During Total Knee Arthroplasty with Use of a Tibial Planing Device
J. Bone Joint Surg. Am., February 1, 2007; 89(2): 381 - 387.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
D. D.R. Naudie, D. J. Ammeen, G. A. Engh, and C. H. Rorabeck
Wear and Osteolysis Around Total Knee Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2007; 15(1): 53 - 64.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
T. P. Firestone and R. W. Eberle
Surgical Management of Symptomatic Instability Following Failed Primary Total Knee Replacement
J. Bone Joint Surg. Am., December 1, 2006; 88(suppl_4): 80 - 84.
[Full Text] [PDF]


Home page
JBJSHome page
M. W. Hanna and T. S. Thornhill
Thigh Mass and Lytic Diaphyseal Femoral Lesion Associated with Polyethylene Wear After Hybrid Total Knee Arthroplasty. A Case Report
J. Bone Joint Surg. Am., November 1, 2006; 88(11): 2473 - 2478.
[Full Text] [PDF]


Home page
JBJSHome page
M. B. Collier, C. A. Engh Jr., J. P. Mcauley, S. D. Ginn, and G. A. Engh
Osteolysis After Total Knee Arthroplasty: Influence of Tibial Baseplate Surface Finish and Sterilization of Polyethylene Insert. Findings at Five to Ten Years Postoperatively
J. Bone Joint Surg. Am., December 1, 2005; 87(12): 2702 - 2708.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
J. R. M. Hutchinson, E. N. Parish, and M. J. Cross
Results of open arthrolysis for the treatment of stiffness after total knee replacement
J Bone Joint Surg Br, October 1, 2005; 87-B(10): 1357 - 1360.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. A. Conditt, M. T. Thompson, M. M. Usrey, S. K. Ismaily, and P. C. Noble
Backside Wear of Polyethylene Tibial Inserts: Mechanism and Magnitude of Material Loss
J. Bone Joint Surg. Am., February 1, 2005; 87(2): 326 - 331.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
M. H. Gonzalez and A. O. Mekhail
The Failed Total Knee Arthroplasty: Evaluation and Etiology
J. Am. Acad. Ortho. Surg., November 1, 2004; 12(6): 436 - 446.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. Kim, C. L. Nelson, and P. A. Lotke
Stiffness After Total Knee Arthroplasty. Prevalence of the Complication and Outcomes of Revision
J. Bone Joint Surg. Am., July 1, 2004; 86(7): 1479 - 1484.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
O. K. Muratoglu, A. Mark, D. A. Vittetoe, W. H. Harris, and H. E. Rubash
Polyethylene Damage in Total Knees and Use of Highly Crosslinked Polyethylene
J. Bone Joint Surg. Am., January 21, 2003; 85(90001): S7 - 13.
[Full Text] [PDF]


Home page
JBJSHome page
A. R. Rao, G. A. Engh, M. B. Collier, and S. Lounici
Tibial Interface Wear in Retrieved Total Knee Components and Correlations with Modular Insert Motion
J. Bone Joint Surg. Am., October 10, 2002; 84(10): 1849 - 1855.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. R. O'Rourke, J. J. Callaghan, D. D. Goetz, P. M. Sullivan, and R. C. Johnston
Osteolysis Associated with a Cemented tModular Posterior-Cruciate-Substituting Total Knee Design : Five to Eight-Year Follow-up
J. Bone Joint Surg. Am., August 12, 2002; 84(8): 1362 - 1371.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
G. C. Babis, R. T. Trousdale, and B. F. Morrey
The Effectiveness of Isolated Tibial Insert Exchange in Revision Total Knee Arthroplasty
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 64 - 68.
[Abstract] [Full Text]


Home page
JBJSHome page
G. C. Babis, R. T. Trousdale, M. W. Pagnano, and B. F. Morrey
Poor Outcomes of Isolated Tibial Insert Exchange and Arthrolysis for the Management of Stiffness Following Total Knee Arthroplasty
J. Bone Joint Surg. Am., October 1, 2001; 83(10): 1534 - 1536.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. J. Archibeck and R. E. White
What's New in Adult Reconstructive Knee Surgery
J. Bone Joint Surg. Am., September 1, 2001; 83(9): 1444 - 1450.
[Full Text] [PDF]


Home page
JAMAHome page
A. L. Boskey
Musculoskeletal Disorders and Orthopedic Conditions
JAMA, February 7, 2001; 285(5): 619 - 623.
[Abstract] [Full Text] [PDF]