This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by PITTO, R. P.
Right arrow Articles by KUEHLE, J. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by PITTO, R. P.
Right arrow Articles by KUEHLE, J. W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 81:831-43 (1999)
© 1999 The Journal of Bone and Joint Surgery, Inc.

Comparison of Fixation of the Femoral Component without Cement and Fixation with Use of a Bone-Vacuum Cementing Technique for the Prevention of Fat Embolism During Total Hip Arthroplasty. A Prospective, Randomized Clinical Trial*

ROCCO PAOLO PITTO, M.D.{dagger}, MATTHIAS KOESSLER, M.D.{dagger} and JOERN W. KUEHLE, M.D.{dagger}, ERLANGEN, GERMANY

Investigation performed at the Department of Orthopaedic Surgery and the Department of Intensive Care and Anesthesiology, University of Erlangen-Nuremberg, Erlangen

Background: Acute hypotension, hypoxemia, cardiac arrest, and sudden death are well recognized complications during total hip arthroplasty, and they have been attributed to embolization of fat and bone marrow. An increase in intramedullary pressure in the femur is the most important pathogenic factor for the development of embolic events. Intravasation of fat, bone marrow, and bone debris during the implantation of a femoral component, and the embolization of these elements through the venous system located along the linea aspera and through the metaphyseal vessels, have been demonstrated experimentally and clinically. The purpose of the present study was to compare the effects of fixation of the femoral component without cement with those of fixation with a bone-vacuum cementing technique on the severity of embolic phenomena and cardiopulmonary impairment during total hip arthroplasty. Fixation with a conventional cementing technique was also evaluated as a control. Methods: Sixty patients (sixty hips) were entered into a prospective, randomized clinical trial. The patients were assigned to one of three groups. Group 1 consisted of twenty patients who had the femoral component inserted without cement, Group 2 comprised twenty patients who had the component inserted with a conventional cementing technique, and Group 3 included twenty patients who had fixation with the so-called bone-vacuum cementing technique. In the hips in Group 3, a suction of -800 millibars (-80,000 pascals) was applied to a proximal drainage cannula placed along the linea aspera and a distal drainage cannula placed in the diaphysis in order to produce a vacuum in the medullary cavity of the femur during the application of cement and the insertion of the stem. Transesophageal echocardiography and hemodynamic and blood-gas analysis were performed during the operation. Results: Severe embolic events (defined as a cascade of fine echogenic particles of less than five millimeters in diameter) were observed in seventeen (85 percent) of the twenty patients during insertion of the stem with use of a conventional cementing technique but in none of the patients who had the stem inserted without cement (p < 0.05). Insertion of the femoral component with the bone-vacuum cementing technique prevented embolic phenomena in all but one patient (5 percent). Arterial oxygen saturation decreased significantly (p < 0.05) from a mean of 99.5 to 92.9 percent after insertion of the stem with a conventional cementing technique, but only slight changes were observed in the patients who had fixation of the component without cement and in those who were managed with the bone-vacuum cementing technique. Intraoperative pulmonary shunt values increased a mean of 24 percent (p < 0.05) when the femoral component was inserted with a conventional cementing technique, but with the numbers available we did not detect a significant change in those values when the component was fixed without cement or when it was inserted with use of the bone-vacuum cementing technique. Conclusions: The present study showed that severe embolic events and intraoperative pulmonary impairment are common when a femoral component is fixed with use of a conventional cementing technique. The results clearly demonstrated a low risk of embolism during total hip arthroplasty when the femoral component was fixed without cement and when it was fixed with the bone-vacuum cementing technique. The ability of a patient to withstand an embolic event should be considered before fixation of the femoral component with use of a conventional cementing technique is planned.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
Y.-H. Kim, J.-S. Kim, K.-S. Hong, Y.-J. Kim, and J.-H. Kim
Prevalence of Fat Embolism After Total Knee Arthroplasty Performed with or without Computer Navigation
J. Bone Joint Surg. Am., January 1, 2008; 90(1): 123 - 128.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
Y.-H. Kim, S.-W. Oh, and J.-S. Kim
Prevalence of Fat Embolism Following Bilateral Simultaneous and Unilateral Total Hip Arthroplasty Performed with or without Cement : A Prospective, Randomized Clinical Study
J. Bone Joint Surg. Am., August 12, 2002; 84(8): 1372 - 1379.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
R. P. Pitto, H. Hamer, R. Fabiani, M. Radespiel-Troeger, and M. Koessler
Prophylaxis Against Fat and Bone-Marrow Embolism During Total Hip Arthroplasty Reduces the Incidence of Postoperative Deep-Vein Thrombosis : A Controlled, Randomized Clinical Trial
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 39 - 48.
[Abstract] [Full Text]


Home page
Anesth. Analg.Home page
G. Ekback, K. Axelsson, L. Ryttberg, B. Edlund, J. Kjellberg, J. Weckstrom, O. Carlsson, and U. Schott
Tranexamic Acid Reduces Blood Loss in Total Hip Replacement Surgery
Anesth. Analg., October 1, 2000; 91(5): 1124 - 1130.
[Abstract] [Full Text] [PDF]