This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by PEARL, M. L.
Right arrow Articles by KURUTZ, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by PEARL, M. L.
Right arrow Articles by KURUTZ, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 81:660-71 (1999)
© 1999 The Journal of Bone and Joint Surgery, Inc.

Geometric Analysis of Commonly Used Prosthetic Systems for Proximal Humeral Replacement*

MICHAEL L. PEARL, M.D.{dagger} and SAM KURUTZ, B.S.{dagger}, LOS ANGELES, CALIFORNIA

Investigation performed at Southern California Permanente Medical Group, Los Angeles

Background: The anatomy of the proximal part of the humerus is extremely variable. The extent to which existing prosthetic systems and operative technique allow replication of this variability has not been established. Methods: Four commonly used press-fit prosthetic systems for shoulder arthroplasty were compared with respect to their ability to match the superior-inferior and medial-lateral dimensions of the articular surface in twenty-one cadaveric humeri. The comparisons were accomplished with a computer optimization algorithm that searched a database of prosthetic geometry and selected the best match to the original anatomy. The algorithm assumed an osteotomy of the humeral head at an angle equivalent to the stem-head angle of the prosthesis, without violation of the greater tuberosity or the metaphyseal bone. The best match was defined as the prosthetic combination (stem and head) that least displaced the center of rotation and the articular surface, with both factors weighted equally. Results: None of the prosthetic systems that were evaluated allowed identical replication of the articular surface. Rather, they displaced the center of rotation a mean of 14.7 millimeters (range, 3.3 to 31.4 millimeters) from its original position. To reach this minimized displacement, the prosthetic combinations that were selected by the algorithm also resulted in a mean diminution of the arc of the articular surface (a smaller head size) of 26 degrees (range, 11 to 41 degrees). In every instance, the selected prosthesis imposed a superior and lateral shift of the center of rotation that in effect shifted a smaller prosthetic humeral head up the slope of the humeral osteotomy. Conclusions: Press-fit prosthetic systems for shoulder arthroplasty that are commonly used necessitate marked alterations of the original anatomy. To the extent that a shoulder arthroplasty is an attempt to reproduce the normal anatomy, these findings have profound implications for operative technique and future prosthetic design. Clinical Relevance: We believe that the superior position of the prosthetic head predicted by the present study plays a role in late complications of shoulder arthroplasty, such as rotator cuff tendinopathy, superior humeral migration, and loosening of the glenoid component.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
P. Boileau, R. J. Sinnerton, C. Chuinard, and G. Walch
Arthroplasty of the shoulder
J Bone Joint Surg Br, May 1, 2006; 88-B(5): 562 - 575.
[Full Text] [PDF]


Home page
JBJSHome page
R. W. Nyffeler, R. Sheikh, H. A.C. Jacob, and C. Gerber
Influence of Humeral Prosthesis Height on Biomechanics of Glenohumeral Abduction. An In Vitro Study
J. Bone Joint Surg. Am., March 1, 2004; 86(3): 575 - 580.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
V. Oztuna, F. Kuyurtar, P. Hernigou, F. Duparc, and A. Hernigou
Determining Humeral Retroversion with Computed Tomography
J. Bone Joint Surg. Am., May 28, 2003; 85(6): 1162 - 1163.
[Full Text] [PDF]


Home page
JBJSHome page
P. Hernigou, F. Duparc, and A. Hernigou
Determining Humeral Retroversion with Computed Tomography
J. Bone Joint Surg. Am., October 10, 2002; 84(10): 1753 - 1762.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
C G Moran and T C Horton
Total knee replacement: the joint of the decade
BMJ, March 25, 2000; 320(7238): 820 - 820.
[Full Text]