This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by SPORER, S. M.
Right arrow Articles by JOHNSTON, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SPORER, S. M.
Right arrow Articles by JOHNSTON, R. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 81:481-92 (1999)
© 1999 The Journal of Bone and Joint Surgery, Inc.

The Effects of Surface Roughness and Polymethylmethacrylate Precoating on the Radiographic and Clinical Results of the Iowa Hip Prosthesis. A Study of Patients Less Than Fifty Years Old*

SCOTT M. SPORER, M.D.{dagger}, JOHN J. CALLAGHAN, M.D.{dagger}, JASON P. OLEJNICZAK, B.A.{dagger}, IOWA CITY, DEVON D. GOETZ, M.D.{ddagger}, WEST DES MOINES and RICHARD C. JOHNSTON, M.D.{dagger}, IOWA CITY, IOWA

Investigation performed at the Iowa Methodist Medical Center, West Des Moines, and the University of Iowa College of Medicine, Iowa City

Background: The purpose of the present study was to compare the results associated with two different surface finishes (bead-blasted and grit-blasted) for Iowa femoral components used in total hip arthroplasties performed between January 1979 and June 1991 in patients who were less than fifty years old. Methods: Between January 1979 and December 1985, thirty-six primary total hip replacements were performed in twenty-five patients with insertion of a bead-blasted Iowa femoral component (average surface roughness, 0.8 micrometer) with cement and insertion of a titanium-backed acetabular component (thirty-five hips) or non-metal-backed acetabular component (one hip) with cement. Between January 1986 and June 1991, forty-five primary total hip replacements were performed in thirty-seven patients with use of a precoated grit-blasted Iowa femoral component (average surface roughness, 2.1 micrometers) and a Harris-Galante-I porous ingrowth acetabular component (forty-one hips) or an Osteonics component (four hips). The only change in the design of the femoral component (other than the surface finish) between the two consecutive series was the addition of polymethylmethacrylate precoating to the proximal third of all forty-five grit-blasted stems and modularity of the femoral head of the last eight grit-blasted stems. Results: No hip was lost to follow-up. The duration of radiographic follow-up of the hips treated with the bead-blasted component averaged 11.3 years (range, ten to sixteen years) postoperatively, whereas that of the hips treated with the precoated grit-blasted component averaged 8.2 years (range, five to eleven years). Two (6 percent) of the bead-blasted femoral components were revised because of aseptic loosening compared with eight (18 percent) of the precoated grit-blasted components. Four bead-blasted components (11 percent) were either radiographically loose or were revised because of loosening compared with eleven precoated grit-blasted components (24 percent). Kaplan-Meier survivorship curves evaluated with log-rank analysis revealed that the bead-blasted Iowa femoral components were revised because of aseptic loosening (p = 0.0184) and were radiographically loose (p = 0.0068) less often than the precoated grit-blasted Iowa femoral components. Conclusions: The findings of the present study have led the senior ones of us to resume using femoral components with a polished surface and fixed with cement.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
D. E. Firestone, J. J. Callaghan, S. S. Liu, D. D. Goetz, P. M. Sullivan, D. A. Vittetoe, and R. C. Johnston
Total Hip Arthroplasty with a Cemented, Polished, Collared Femoral Stem and a Cementless Acetabular Component. A Follow-up Study at a Minimum of Ten Years
J. Bone Joint Surg. Am., January 1, 2007; 89(1): 126 - 132.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
H. Ito, T. Matsuno, and A. Minami
Pre-coated femoral components in hybrid total hip arthroplasty: RESULTS AT 11 YEARS
J Bone Joint Surg Br, March 1, 2005; 87-B(3): 306 - 309.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. Sanchez-Sotelo, D. J. Berry, and S. Harmsen
Long-Term Results of Use of a Collared Matte-Finished Femoral Component Fixed with Second-Generation Cementing Techniques : A Fifteen-Year-Median Follow-up Study
J. Bone Joint Surg. Am., September 3, 2002; 84(9): 1636 - 1641.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. Ong, K. L. Wong, M. Lai, J. P. Garino, and M. E. Steinberg
Early Failure of Precoated Femoral Components in Primary Total Hip Arthroplasty
J. Bone Joint Surg. Am., May 1, 2002; 84(5): 786 - 792.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
D. K. Collis and C. G. Mohler
Comparison of Clinical Outcomes in Total Hip Arthroplasty Using Rough and Polished Cemented Stems with Essentially the Same Geometry
J. Bone Joint Surg. Am., April 1, 2002; 84(4): 586 - 592.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
V. P. Cannestra, R. A. Berger, L. R. Quigley, J. J. Jacobs, A. G. Rosenberg, and J. O. Galante
Hybrid Total Hip Arthroplasty with a Precoated Offset Stem : Four to Nine-Year Results
J. Bone Joint Surg. Am., September 1, 2000; 82(9): 1291 - 1291.
[Abstract] [Full Text]