This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by GOURINENI, P. V. R. K. V.
Right arrow Articles by NUBER, G. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by GOURINENI, P. V. R. K. V.
Right arrow Articles by NUBER, G. F.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 81:364-9 (1999)
© 1999 The Journal of Bone and Joint Surgery, Inc.

Radiographic Evaluation of the Position of Implants in the Medial Malleolus in Relation to the Ankle Joint Space: Anteroposterior Compared with Mortise Radiographs*

PRASAD V. R. K. V. GOURINENI, M.D.{dagger}, ALBERT E. KNUTH, M.D.{ddagger} and GORDON F. NUBER, M.D.§, CHICAGO, ILLINOIS

Investigation performed at the Department of Orthopaedic Surgery, Northwestern University Medical School, Chicago

Background: Displaced transverse fractures of the medial malleolus are commonly treated with open reduction and internal fixation with two screws or wires. A mortise radiograph is often used to verify the position of the implants relative to the joint space. However, because the medial and lateral talomalleolar spaces are normally not parallel, the mortise projection (which is colinear with the lateral space) does not provide an accurate radiograph of the medial joint space. Methods: In ten cadaveric ankles, two wires were inserted into the medial malleolus, as is done for fixation of a fracture, and the distance of the wires from the joint space was measured on an anteroposterior radiograph, on mortise radiographs made with the foot in 15 and 30 degrees of internal rotation, and on anatomical cross section. Results: The measurement on the anteroposterior radiograph exceeded the anatomical measurement in only two specimens, and the discrepancy was 0.5 millimeter in both instances. Measurement of the osseous thickness between the joint surface and the posterior wire on the mortise radiographs always revealed a lower value than the measurements on the anteroposterior radiograph and the anatomical cross section of the same specimen. There was a false appearance of intra-articular placement of the posterior wire on the 15-degree mortise radiographs of four specimens and on the 30-degree mortise radiographs of eight specimens. Conclusions: These findings demonstrate that the mortise projection provides an oblique radiograph of the medial joint space that can inaccurately reflect the true position of fixation implants in the medial malleolus. Because an anteroposterior radiograph is made with the articular surface of the medial malleolus tangential to the beam, it provides a more accurate representation of implants in the medial malleolus. Clinical Relevance: We recommend the use of an anteroposterior radiograph to properly evaluate the position of implants used in the treatment of transverse fractures of the medial malleolus. This type of radiograph allows a more lateral starting point for insertion of the fixation device, more accurate intraoperative evaluation of the position of the implants, and better fixation of fractures of the medial malleolus.