The Journal of Bone and Joint Surgery 81:247-255 (1999)
© 1999 The Journal of Bone and Joint Surgery, Inc.
Primary Hybrid Total Hip Replacement, Performed with Insertion of the Acetabular Component without Cement and a Precoat Femoral Component with Cement. An Average Ten-Year Follow-up Study*
JOHN C. CLOHISY, M.D. and
WILLIAM H. HARRIS, M.D. , BOSTON, MASSACHUSETTS
Investigation performed at the Orthopaedic Biomechanics Laboratory and the Adult Reconstructive Service, Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston
One hundred and twenty-one primary hybrid total hip replacements were performed in 107 patients. A titanium, porous-coated, hemispherical acetabular component was fixed with screws, and a collared, chromium-cobalt femoral stem, with a roughened surface and a thin layer of methylmethacrylate on the proximal third, was inserted with contemporary cementing techniques (that is, use of a femoral medullary plug, a cement gun, and centrifugation and pressurization of the cement). Fifteen patients (fifteen hips) died before a minimum duration of follow-up of seven years, four patients (four hips) were too ill for a detailed follow-up examination at the time of the study, and two patients (two hips) refused to be evaluated at the time of the latest follow-up. None of these twenty-one hips had had a revision or a reoperation at the time of the latest follow-up. Eighty-six patients (100 hips) were available for clinical follow-up at an average of 120 months (range, eighty-four to 153 months) and for radiographic follow-up at an average of 118 months (range, eighty-four to 153 months). The average age of the patients at the time of the index arthroplasty was sixty-five years (range, forty-five to eighty-seven years). Three acetabular components were revised because of dissociation of the liner in association with a fracture of a locking tine. One well fixed acetabular component was revised because of pelvic osteolysis, and the femoral stem in the same patient was revised because of aseptic loosening.
None of the ninety-six remaining acetabular components migrated, was classified as radiographically loose, or was revised because of aseptic loosening. Osteolytic lesions were identified adjacent to five acetabular components, and one of them was treated with bone-grafting around the well fixed acetabular shell. Two hips had a continuous radiolucent line at the interface between the acetabular implant and the bone.
Three femoral stems had evidence of radiographic debonding (a radiolucent line that was one millimeter wide or less between the cement and the prosthesis), and they were classified as radiographically loose despite excellent clinical results. Seven hips had osteolytic areas located in the proximal aspect of the most proximal zones of Gruen et al., and five had small osteolytic regions in more distal areas.
The Harris hip score for the eighty-two patients (ninety-six hips) who did not have a revision improved from 48 points (range, 22 to 70 points) preoperatively to 92 points (range, 53 to 100 points) at the most recent follow-up examination. Eighty-one patients had no, slight, or mild pain in the hip, and they were satisfied with the clinical result. In the present study, the hybrid total hip replacement with use of the Harris-Galante acetabular component and the Precoat femoral stem continued to provide an excellent result for most patients at an average of approximately ten years after the operation.

CiteULike Connotea Del.icio.us Facebook Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
W. Jin, Y. S. Chun, S. Y. Park, K. H. Rhyu, J. S. Park, H. C. Kim, D. M. Yang, and K. N. Ryu
Sonographic Detection of Acetabular Polyethylene Liner Dissociation in Total Hip Arthroplasty
J. Ultrasound Med.,
November 1, 2009;
28(11):
1597 - 1600.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. F. Lachiewicz, S. S. Kelley, and E. S. Soileau
Survival of Polished Compared with Precoated Roughened Cemented Femoral Components. A Prospective, Randomized Study
J. Bone Joint Surg. Am.,
July 1, 2008;
90(7):
1457 - 1463.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Ito, T. Matsuno, and A. Minami
Pre-coated femoral components in hybrid total hip arthroplasty: RESULTS AT 11 YEARS
J Bone Joint Surg Br,
March 1, 2005;
87-B(3):
306 - 309.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Ito, T. Matsuno, A. Minami, and Y. Aoki
Intermediate-Term Results After Hybrid Total Hip Arthroplasty for the Treatment of Dysplastic Hips
J. Bone Joint Surg. Am.,
September 1, 2003;
85(9):
1725 - 1732.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y.-H. Kim, S.-H. Oh, and J.-S Kim
Primary Total Hip Arthroplasty with a Second-Generation Cementless Total Hip Prosthesis in Patients Younger Than Fifty Years of Age
J. Bone Joint Surg. Am.,
January 17, 2003;
85(1):
109 - 114.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Ong, K. L. Wong, M. Lai, J. P. Garino, and M. E. Steinberg
Early Failure of Precoated Femoral Components in Primary Total Hip Arthroplasty
J. Bone Joint Surg. Am.,
May 1, 2002;
84(5):
786 - 792.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. A. Harrington Jr., D. O. O'Connor, A. J. Lozynsky, I. Kovach, and W. H. Harris
Effects of Femoral Neck Length, Stem Size, and Body Weight on Strains in the Proximal Cement Mantle
J. Bone Joint Surg. Am.,
April 1, 2002;
84(4):
573 - 579.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. E. Templeton, J. J. Callaghan, D. D. Goetz, P. M. Sullivan, and R. C. Johnston
Revision of a Cemented Acetabular Component to a Cementless Acetabular Component : A Ten to Fourteen-Year Follow-up Study
J. Bone Joint Surg. Am.,
November 1, 2001;
83(11):
1706 - 1711.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Bhandari, G. H. Guyatt, and M. F. Swiontkowski
User's Guide to the Orthopaedic Literature: How to Use an Article About Prognosis
J. Bone Joint Surg. Am.,
October 1, 2001;
83(10):
1555 - 1564.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. G. DellaValle, P. S. Ruzo, S. Li, P. Pellicci, T. P. Sculco, and E. A. Salvati
Dislodgment of Polyethylene Liners in First and Second-Generatio{-}n Harris-Galante Acetabular Components : A Report of Eighteen Cases
J. Bone Joint Surg. Am.,
April 1, 2001;
83(4):
553 - 553.
[Abstract]
[Full Text]
|
 |
|
|