This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by PETERSEN, M. B.
Right arrow Articles by SOLGAARD, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by PETERSEN, M. B.
Right arrow Articles by SOLGAARD, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 81:219-224 (1999)
© 1999 The Journal of Bone and Joint Surgery, Inc.

The Hemispherical Harris-Galante Acetabular Cup, Inserted without Cement. The Results of an Eight to Eleven-Year Follow-up of One Hundred and Sixty-Eight Hips*

M. B. PETERSEN, M.D.{dagger}, I. H. POULSEN, M.D.{dagger}, J. THOMSEN, M.D.{dagger} and S. SOLGAARD, DR.MED.SCI.{dagger}, HILLERØD, DENMARK

Investigation performed at the Department of Orthopaedic Surgery, Hillerød Hospital, Hillerød

We studied the results for 168 available hips from a series of 324 consecutive primary total hip arthroplasties that had been performed with insertion of a Harris-Galante-I acetabular component without cement. The acetabulum had been reamed in a so-called line-to-line manner, and the cup had been fixed with one to four screws. A femoral component with a modular alumina-ceramic head had been inserted with cement in all hips. The median duration of follow-up was 112 months (range, 101 to 131 months). Of the original 324 hips, 109 could not be included in the clinical and radiographic follow-up because the patients had died and thirty could not be included because the patients were not available for examination. Seventeen hips had had a revision of the acetabular cup: five, because of infection; five, because of dislocation; three, because of aseptic loosening; and four, because of technical failure. This left 168 hips for clinical and radiographic follow-up; of these, fifteen had had a revision of the femoral component only. Of the remaining 153 hips, which had not had a revision, 147 (96 percent) were considered by the patient to have a satisfactory, good, or excellent result. One hip was found to have a loose cup on radiographic evaluation and was therefore considered to have failed, but the clinical function was good. We concluded that, with an overall rate of aseptic loosening of 1 percent (four of 324) after an intermediate (ten-year) duration of follow-up, use of this cup has good results.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
K. F. Bonner, R. E. Delanois, G. Harbach, M. Bushelow, and M. A. Mont
Cementation of a Polyethylene Liner into a Metal Shell : Factors Related to Mechanical Stability
J. Bone Joint Surg. Am., September 3, 2002; 84(9): 1587 - 1593.
[Abstract] [Full Text] [PDF]