This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MARCO, R. A. W.
Right arrow Articles by ZISSIMOS, A. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MARCO, R. A. W.
Right arrow Articles by ZISSIMOS, A. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 80:1012-19 (1998)
© 1998 The Journal of Bone and Joint Surgery, Inc.

Pathomechanics of Closed Rupture of the Flexor Tendon Pulleys in Rock Climbers*

REX A. W. MARCO, M.D.{dagger}, NEIL A. SHARKEY, PH.D.{ddagger}, TAIT S. SMITH, M.S.{dagger} and ANTHONY G. ZISSIMOS, M.D.§, SACRAMENTO, CALIFORNIA

Investigation performed at the Orthopaedic Research Laboratories, University of California, Davis, School of Medicine, Sacramento

We performed a study on twenty-one cadaveric fingers (seven non-paired forearms) to determine the pathomechanics of closed traumatic rupture of the flexor tendon pulleys in rock climbers. The ages of the individuals at the time of death ranged from sixty-one to eighty-four years (mean, seventy-four years). The forearm was placed in a custom-made loading apparatus, and individual fingers were tested separately under simulated in vivo loading conditions. The flexor digitorum superficialis and profundus tendons of each digit were attached to computer-controlled linear stepper motors that were equipped with force transducers, and the force in the tendons was simultaneously increased until avulsion of the tendons or osseous failure occurred. The force in the tendons, the excursion of the tendons, and the force at the fingertip were measured. Damage to the pulleys and bowstringing of the tendons were visualized with a fiberoptic camera. Two fingers fractured before complete rupture of the pulleys. Seventeen of the remaining nineteen fingers sustained an isolated rupture of either the A2 or the A4 pulley as the initial failure event; the A4 pulley ruptured first in fourteen digits (p < 0.001). The A3 and A4 pulleys ruptured simultaneously in one finger, and the A2, A3, and A4 pulleys ruptured simultaneously in another. Subtle bowstringing of the flexor digitorum profundus tendon occurred only after two consecutive pulleys had ruptured (either the A2 and A3 pulleys or the A3 and A4 pulleys). Rupture of all three pulleys was required to produce obvious bowstringing. Isolated rupture of the A2 or A4 pulley did not result in detectable bowstringing of the flexor digitorum profundus tendon. The A1 pulley always remained intact. CLINICAL RELEVANCE: Bowstringing of the flexor digitorum profundus tendon across the proximal interphalangeal joint with resisted flexion of the fingertips has been considered diagnostic for isolated closed rupture of the A2 pulley. The results of the present study, however, suggest that isolated injury of the A2 pulley rarely occurs. On the basis of our findings, we believe that reliance on bowstringing of the tendon at the proximal interphalangeal joint as an indicator of an isolated rupture of the A2 or A4 pulley may be misleading.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
J. D. Michelson, A. J. Hamel, F. L. Buczek, and N. A. Sharkey
Kinematic Behavior of the Ankle Following Malleolar Fracture Repair in a High-Fidelity Cadaver Model
J. Bone Joint Surg. Am., November 12, 2002; 84(11): 2029 - 2038.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. A. Clavero, X. Alomar, J. M. Monill, M. Esplugas, P. Golano, M. Mendoza, and A. Salvador
MR Imaging of Ligament and Tendon Injuries of the Fingers
RadioGraphics, March 1, 2002; 22(2): 237 - 256.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. Hauger, C. B. Chung, N. Lektrakul, M. J. Botte, D. Trudell, R. D. Boutin, and D. Resnick
Pulley System in the Fingers: Normal Anatomy and Simulated Lesions in Cadavers at MR Imaging, CT, and US with and without Contrast Material Distention of the Tendon Sheath
Radiology, October 1, 2000; 217(1): 201 - 212.
[Abstract] [Full Text]


Home page
Am J Sports MedHome page
W. J. Warme and D. Brooks
The Effect of Circumferential Taping on Flexor Tendon Pulley Failure in Rock Climbers
Am. J. Sports Med., September 1, 2000; 28(5): 674 - 678.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Klauser, F. Frauscher, G. Bodner, E. J. Halpern, M. F. Schocke, P. Springer, M. Gabl, W. Judmaier, and D. zur Nedden
Finger Pulley Injuries in Extreme Rock Climbers: Depiction with Dynamic US
Radiology, March 1, 2002; 222(3): 755 - 761.
[Abstract] [Full Text] [PDF]