This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Related articles in JBJS
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by GOETZ, D. D.
Right arrow Articles by JOHNSTON, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by GOETZ, D. D.
Right arrow Articles by JOHNSTON, R. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 80:502-9 (1998)
© 1998 The Journal of Bone and Joint Surgery, Inc.

Salvage of a Recurrently Dislocating Total Hip Prosthesis with Use of a Constrained Acetabular Component. A Retrospective Analysis of Fifty-six Cases*

DEVON D. GOETZ, M.D.{dagger}, DES MOINES, WILLIAM N. CAPELLO, M.D.{ddagger}, INDIANAPOLIS, INDIANA, JOHN J. CALLAGHAN, M.D.§, THOMAS D. BROWN, PH.D.§, IOWA CITY and RICHARD C. JOHNSTON, M.D.{dagger}, DES MOINES, IOWA

Investigation performed at Iowa Methodist Medical Center, Des Moines; Indiana University Medical Center, Indianapolis; and the University of Iowa College of Medicine, Iowa City

Fifty-six constrained acetabular components were placed, between April 1988 and February 1993, in fifty-five patients who had had recurrent dislocations (average, six dislocations; range, two to twenty dislocations) of the femoral component after a previous total hip arthroplasty. All patients had additional factors contributing to the instability of the implant, including absence or disruption of the abductor mechanism, poor health, mental retardation, confusion, and Alzheimer disease. One patient was lost to follow-up. The remaining patients were followed clinically for a minimum of three years (average, sixty-four months; range, thirty-seven to ninety-seven months) or until the time of death. During the follow-up interval, only two (4 per cent) of the fifty-five patients had a subsequent dislocation. The use of this type of component should be considered for patients who have recurrent dislocation if other treatment modalities are unlikely to be effective.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?

Related articles in JBJS:

Salvage of a Recurrently Dislocating Total Hip Prosthesis with Use of a Constrained Acetabular Component. A Concise Follow-up of a Previous Report
Devon D. Goetz, Barron R.B. Bremner, John J. Callaghan, William N. Capello, and Richard C. Johnston
JBJS 2004 86: 2419-2423. [Abstract] [Full Text]  



This article has been cited by other articles:


Home page
JBJSHome page
O. Guyen, D. G. Lewallen, and M. E. Cabanela
Modes of Failure of Osteonics Constrained Tripolar Implants: A Retrospective Analysis of Forty-three Failed Implants
J. Bone Joint Surg. Am., July 1, 2008; 90(7): 1553 - 1560.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. Parvizi, E. Picinic, and P. F. Sharkey
Revision Total Hip Arthroplasty for Instability: Surgical Techniques and Principles
J. Bone Joint Surg. Am., May 1, 2008; 90(5): 1134 - 1142.
[Full Text] [PDF]


Home page
JBJSHome page
D. D. Goetz, B. R.B. Bremner, J. J. Callaghan, W. N. Capello, and R. C. Johnston
Salvage of a Recurrently Dislocating Total Hip Prosthesis with Use of a Constrained Acetabular Component. A Concise Follow-up of a Previous Report
J. Bone Joint Surg. Am., November 1, 2004; 86(11): 2419 - 2423.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. J. Callaghan, J. Parvizi, C. C. Novak, B. Bremner, W. Shrader, D. G. Lewallen, R. C. Johnston, and D. D. Goetz
A Constrained Liner Cemented into a Secure Cementless Acetabular Shell
J. Bone Joint Surg. Am., October 1, 2004; 86(10): 2206 - 2211.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
M. Soong, H. E. Rubash, and W. Macaulay
Dislocation After Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., September 1, 2004; 12(5): 314 - 321.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. E. Beaule, E. Ebramzadeh, M. LeDuff, R. Prasad, and H. C. Amstutz
Cementing a Liner into a Stable Cementless Acetabular Shell: The Double-Socket Technique
J. Bone Joint Surg. Am., May 1, 2004; 86(5): 929 - 934.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. W. Shrader, J. Parvizi, and D. G. Lewallen
The Use of a Constrained Acetabular Component to Treat Instability After Total Hip Arthroplasty
J. Bone Joint Surg. Am., November 1, 2003; 85(11): 2179 - 2183.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
G. F. Haft, A. D. Heiner, L. D. Dorr, T. D. Brown, and J. J. Callaghan
A Biomechanical Analysis of Polyethylene Liner Cementation into a Fixed Metal Acetabular Shell
J. Bone Joint Surg. Am., May 28, 2003; 85(6): 1100 - 1110.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
K. F. Bonner, R. E. Delanois, G. Harbach, M. Bushelow, and M. A. Mont
Cementation of a Polyethylene Liner into a Metal Shell : Factors Related to Mechanical Stability
J. Bone Joint Surg. Am., September 3, 2002; 84(9): 1587 - 1593.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
P. F. Lachiewicz and S. S. Kelley
The Use of Constrained Components in Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., July 1, 2002; 10(4): 233 - 238.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. E. Beaule, T. P. Schmalzried, P. Udomkiat, and H. C. Amstutz
Jumbo Femoral Head for the Treatment of Recurrent Dislocation Following Total Hip Replacement
J. Bone Joint Surg. Am., February 1, 2002; 84(2): 256 - 263.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
S. D. Toomey, R. H. Hopper Jr., J. P. McAuley, and C. A. Engh
Modular Component Exchange for Treatment of Recurrent Dislocation of a Total Hip Replacement in Selected Patients
J. Bone Joint Surg. Am., October 1, 2001; 83(10): 1529 - 1533.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. Parvizi and B. F. Morrey
Bipolar Hip Arthroplasty as a Salvage Treatment for Instability of the Hip
J. Bone Joint Surg. Am., August 1, 2000; 82(8): 1132 - 1132.
[Abstract] [Full Text]


Home page
JBJSHome page
F. S. HADDAD, D. S. GARBUZ, B. A. MASRI, C. P. DUNCAN, C. R. HUTCHISON, and A. E. GROSS
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Femoral Bone Loss in Patients Managed with Revision Hip Replacement: Results of Circumferential Allograft Replacement*{{dagger}}
J. Bone Joint Surg. Am., March 1, 1999; 81(3): 420 - 36.
[Full Text]