This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BOURNE, R. B.
Right arrow Articles by ROBERTSON, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by BOURNE, R. B.
Right arrow Articles by ROBERTSON, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 80:1775-80 (1998)
© 1998 The Journal of Bone and Joint Surgery, Inc.

The Harris Design-2 Total Hip Replacement Fixed with So-Called Second-Generation Cementing Techniques. A Ten to Fifteen-Year Follow-up*

R. B. BOURNE, M.D., F.R.C.S.(C){dagger}, C. H. RORABECK, M.D., F.R.C.S.(C){dagger}, M. SKUTEK, {dagger}, S. MIKKELSEN, {dagger}, M. WINEMAKER, M.D.{dagger} and D. ROBERTSON, R.N.{dagger}, LONDON, ONTARIO, CANADA

Investigation performed at London Health Sciences Centre, The University of Western Ontario, London

We analyzed the clinical results of 195 Harris Design-2 total hip replacements performed with so-called second-generation cementing techniques in 166 consecutive patients who had osteoarthrosis. The mean age of the patients at the time of the replacement was sixty-seven years and nine months (range, thirty-one to eighty-nine years). Forty-eight patients (fifty-four hips) died before the time of the latest follow-up, but the implants were apparently functioning well at the time of death. Three patients (four hips) were lost to follow-up. Five patients (five hips; 3 percent) had a revision because of aseptic loosening of the acetabular or femoral component, or both, that was related to wear-induced osteolysis. The mean Harris hip score for the 131 hips that were available at the latest follow-up examination at a mean of twelve years (range, ten to fifteen years) after the operation was 89 ± 10 points. On the basis of the Harris hip score, seventy-six hips had an excellent result, thirty-four had a good result, fifteen had a fair result, and six had a poor result at the latest follow-up examination. Radiographically, twelve (9 percent) of the 131 acetabular components and three (2 percent) of the 131 femoral components were probably or definitely loose. At a mean of twelve years, 186 (97 percent) of 191 Harris Design-2 implants were in situ or had been in situ at the time of the patient's death.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
M. Skutek, R. B. Bourne, C. H. Rorabeck, A. Burns, S. Kearns, and G. Krishna
The Twenty to Twenty-five-Year Outcomes of the Harris Design-2 Matte-Finished Cemented Total Hip Replacement. A Concise Follow-up of a Previous Report
J. Bone Joint Surg. Am., April 1, 2007; 89(4): 814 - 818.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. Laupacis, R. Bourne, C. Rorabeck, D. Feeny, P. Tugwell, and C. Wong
Comparison of Total Hip Arthroplasty Performed with and without Cement : A Randomized Trial
J. Bone Joint Surg. Am., October 10, 2002; 84(10): 1823 - 1828.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. Sanchez-Sotelo, D. J. Berry, and S. Harmsen
Long-Term Results of Use of a Collared Matte-Finished Femoral Component Fixed with Second-Generation Cementing Techniques : A Fifteen-Year-Median Follow-up Study
J. Bone Joint Surg. Am., September 3, 2002; 84(9): 1636 - 1641.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. Ong, K. L. Wong, M. Lai, J. P. Garino, and M. E. Steinberg
Early Failure of Precoated Femoral Components in Primary Total Hip Arthroplasty
J. Bone Joint Surg. Am., May 1, 2002; 84(5): 786 - 792.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
D. C. Mears and J. H. Velyvis
Acute Total Hip Arthroplasty for Selected Displaced Acetabular Fractures : Two to Twelve-Year Results
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 1 - 9.
[Abstract] [Full Text]