This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by YOON, T. R.
Right arrow Articles by MALONEY, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by YOON, T. R.
Right arrow Articles by MALONEY, W. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 80:1459-67 (1998)
© 1998 The Journal of Bone and Joint Surgery, Inc.

Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*

TAEK RIM YOON, M.D.{dagger}, SUNG MAN ROWE, M.D.{dagger}, SUNG TAEK JUNG, M.D.{dagger}, KWANG JIN SEON, M.D.{dagger}, KWANGJU, KOREA and WILLIAM J. MALONEY, M.D.{ddagger}, ST. LOUIS, MISSOURI

Investigation performed at the Chonnam University Hospital, Kwangju

The results of 103 total hip arthroplasties performed with insertion of a ceramic femoral head and acetabular component in ninety-six patients were reviewed to determine the radiographic prevalence of osteolysis. After a mean duration of follow-up of ninety-two months (range, sixty to 125 months), femoral osteolysis was observed in twenty-three hips (22 per cent), in one of two distinct patterns: linear osteolysis (twelve hips) or scalloping expansile-type osteolysis (eleven hips). The most common locations of osteolysis in the femur were in zones I and VII as described by Gruen et al. Serial radiographs demonstrated that the extent of the osteolysis progressed over time. Osteolysis of the pelvis, noted in forty-nine hips, was always associated with migration of the acetabular socket. No focal osteolysis was observed in association with the stable sockets. Ten patients (ten hips) had a revision because of loosening and migration of the acetabular component. In three of these patients, the femoral stem also was revised. Gross examination revealed evidence of wear of the ceramic bearing surface in all ten patients. Scanning electron microscopy showed cracking and wear marks on the weight-bearing surface. Histological evaluation of the tissue in the periprosthetic membrane demonstrated abundant ceramic wear particles. The interface membrane was composed of a vascularized fibrous connective tissue with macrophages. Ultrastructurally, the macrophages contained numerous phagosomes of various sizes, with electron-dense material within the cytoplasm of the cell. The mean size of the ceramic particles, as determined with scanning electron microscopy, was 0.71 micrometer (range, 0.13 to 7.20 micrometers). This study supports the concept that ceramic wear particles can stimulate a foreign-body response and periprosthetic osteolysis.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J Am Acad Orthop SurgHome page
J. J. Callaghan, J. M. Cuckler, J. I. Huddleston, and J. O. Galante
How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis?
J. Am. Acad. Ortho. Surg., July 1, 2008; 16(suppl_1): S33 - S38.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
J. J. Jacobs, P. A. Campbell, and Y. T. Konttinen
How has the biologic reaction to wear particles changed with newer bearing surfaces?
J. Am. Acad. Ortho. Surg., July 1, 2008; 16(suppl_1): S49 - S55.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
I. C. Clarke and M. T. Manley
How do alternative bearing surfaces influence wear behavior?
J. Am. Acad. Ortho. Surg., July 1, 2008; 16(suppl_1): S86 - S93.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P.J. Lusty, C.C. Tai, R.P. Sew-Hoy, W.L. Walter, W.K. Walter, and B.A. Zicat
Third-Generation Alumina-on-Alumina Ceramic Bearings in Cementless Total Hip Arthroplasty
J. Bone Joint Surg. Am., December 1, 2007; 89(12): 2676 - 2683.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
K. W. Nam, J. J. Yoo, Y. Lae Kim, Y.-M. Kim, M.-H. Lee, and H. J. Kim
Alumina-Debris-Induced Osteolysis in Contemporary Alumina-on-Alumina Total Hip Arthroplasty. A Case Report
J. Bone Joint Surg. Am., November 1, 2007; 89(11): 2499 - 2503.
[Full Text] [PDF]


Home page
JBJSHome page
J. J. Yoo, H. J. Kim, and Y.-M. Kim
Damage of an Alumina-on-Alumina Bearing Surface from a Difficult Reduction of a Total Hip Arthroplasty. A Report of Three Cases
J. Bone Joint Surg. Am., February 1, 2004; 86(2): 376 - 378.
[Full Text] [PDF]


Home page
JBJSHome page
C. Heisel, M. Silva, and T. P. Schmalzried
Bearing Surface Options for Total Hip Replacement in Young Patients
J. Bone Joint Surg. Am., July 3, 2003; 85(7): 1366 - 1379.
[Full Text] [PDF]


Home page
JBJSHome page
M. Hamadouche, P. Boutin, J. Daussange, M. E. Bolander, and L. Sedel
Alumina-on-Alumina Total Hip Arthroplasty : A Minimum 18.5-Year Follow-up Study
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 69 - 77.
[Abstract] [Full Text]