The Journal of Bone and Joint Surgery 80:54-9 (1998)
© 1998 The Journal of Bone and Joint Surgery, Inc.
Quantitative Assessment of Walking Activity after Total Hip or Knee Replacement*
THOMAS P. SCHMALZRIED, M.D. ,
EDWARD S. SZUSZCZEWICZ, M.D. ,
MARK R. NORTHFIELD, M.D. ,
KENNETH H. AKIZUKI, M.D. ,
RYAN E. FRANKEL, B.S. ,
GREG BELCHER, M.D. and
HARLAN C. AMSTUTZ, M.D. , LOS ANGELES, CALIFORNIA
Investigation performed at Joint Replacement Institute at Orthopaedic Hospital, Los Angeles.
Accumulating data suggest that the amount of use, and not simply the duration in situ, influences the wear and survival of total joint replacements. An electronic, digital pedometer was used to record the number of steps taken by 111 non-randomized volunteers who had had at least one total hip or knee replacement.
The patients averaged 4988 steps per day, which extrapolates to approximately 0.9 million cycles per year for each joint of the lower extremity. Average activity ranged widely from 395 to 17,718 steps per day, an approximately forty-five-fold difference. The most active patient walked more than 3.5 times the average number of steps per day. Age was significantly associated with activity (p = 0.048), but there was a high degree of variability (standard deviation, 3040 steps per day). Patients who were less than sixty years old walked 30 per cent more on average than those who were sixty years old or more (p = 0.023). Men walked 28 per cent more on average than women (p = 0.037), and men who were less than sixty years old walked 40 per cent more on average than the rest of the patients (p = 0.011). These data indicate that individual differences in the activity of the patient can be a substantial source of variability in rates of polyethylene wear in vivo.
The pedometer is an inexpensive investigational tool with many potential applications, including standardizing wear measurements of joint replacements on the basis of gait cycles rather than time. This quantitative approach may provide prognostic information regarding the survival of joint prostheses. Pedometer data may also be useful for quantitative assessment of walking ability in outcome studies.

CiteULike Connotea Del.icio.us Technorati What's this?
This article has been cited by other articles:

|
 |

|
 |
 
A. K. Tsao, L. C. Jones, and D. G. Lewallen
What patient and surgical factors contribute to implant wear and osteolysis in total joint arthroplasty?
J. Am. Acad. Ortho. Surg.,
July 1, 2008;
16(suppl_1):
S7 - S13.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Wagenmakers, M. Stevens, I. van den Akker-Scheek, W. Zijlstra, and J. W Groothoff
Predictive Value of the Western Ontario and McMaster Universities Osteoarthritis Index for the Amount of Physical Activity After Total Hip Arthroplasty
Physical Therapy,
February 1, 2008;
88(2):
211 - 218.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F.-D. Naal, N. A. Maffiuletti, U. Munzinger, and O. Hersche
Sports After Hip Resurfacing Arthroplasty
Am. J. Sports Med.,
May 1, 2007;
35(5):
705 - 711.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. E Berlin, K. L Storti, and J. S Brach
Using Activity Monitors to Measure Physical Activity in Free-Living Conditions
Physical Therapy,
August 1, 2006;
86(8):
1137 - 1145.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K Huch, K A C Muller, T Sturmer, H Brenner, W Puhl, and K-P Gunther
Sports activities 5 years after total knee or hip arthroplasty: the Ulm Osteoarthritis Study
Ann Rheum Dis,
December 1, 2005;
64(12):
1715 - 1720.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. J. Price, C. A. F. Dodd, U. G. C. Svard, and D. W. Murray
Oxford medial unicompartmental knee arthroplasty in patients younger and older than 60 years of age
J Bone Joint Surg Br,
November 1, 2005;
87-B(11):
1488 - 1492.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. J. Saleh, K. J. Mulhall, B. Bershadsky, H. M. Ghomrawi, L. E. White, C. M. Buyea, and K. A. Krackow
Development and Validation of a Lower-Extremity Activity Scale. Use for Patients Treated with Revision Total Knee Arthroplasty
J. Bone Joint Surg. Am.,
September 1, 2005;
87(9):
1985 - 1994.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Heisel, M. Silva, A. K. Skipor, J. J. Jacobs, and T. P. Schmalzried
The Relationship Between Activity and Ions in Patients with Metal-on-Metal Bearing Hip Prostheses
J. Bone Joint Surg. Am.,
April 1, 2005;
87(4):
781 - 787.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. G. Armstrong, L. A. Lavery, K. Holtz-Neiderer, M. J. Mohler, C. S. Wendel, B. P. Nixon, and A. J.M. Boulton
Variability in Activity May Precede Diabetic Foot Ulceration
Diabetes Care,
August 1, 2004;
27(8):
1980 - 1984.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. J. Sychterz, K. F. Orishimo, and C. A. Engh
Sterilization and Polyethylene Wear: Clinical Studies to Support Laboratory Data
J. Bone Joint Surg. Am.,
May 1, 2004;
86(5):
1017 - 1022.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Heisel, M. Silva, M. A. dela Rosa, and T. P. Schmalzried
Short-Term in Vivo Wear of Cross-Linked Polyethylene
J. Bone Joint Surg. Am.,
April 1, 2004;
86(4):
748 - 751.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. W. Pennington, J. J. Swienckowski, W. B. Lutes, and G. N. Drake
Unicompartmental Knee Arthroplasty in Patients Sixty Years of Age or Younger
J. Bone Joint Surg. Am.,
October 1, 2003;
85(10):
1968 - 1973.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
D. G. Armstrong, L. A. Lavery, H. R. Kimbriel, B. P. Nixon, and A. J.M. Boulton
Activity Patterns of Patients With Diabetic Foot Ulceration: Patients with active ulceration may not adhere to a standard pressure off-loading regimen
Diabetes Care,
September 1, 2003;
26(9):
2595 - 2597.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. H. Hopper Jr., A. M. Young, K. F. Orishimo, and C. A. Engh Jr.
Effect of Terminal Sterilization with Gas Plasma or Gamma Radiation on Wear of Polyethylene Liners
J. Bone Joint Surg. Am.,
March 11, 2003;
85(3):
464 - 468.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. G. Armstrong, P. L. Abu-Rumman, B. P. Nixon, and A. J.M. Boulton
Continuous Activity Monitoring in Persons at High Risk for Diabetes-Related Lower-Extremity Amputation
J Am Podiatr Med Assoc,
October 1, 2001;
91(9):
451 - 455.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. G. Armstrong and A. J.M. Boulton
Activity Monitors: Should We Begin Dosing Activity as We Dose a Drug?
J Am Podiatr Med Assoc,
March 1, 2001;
91(3):
152 - 153.
[Full Text]
|
 |
|

|
 |

|
 |
 
H. McKellop, F.-w. Shen, B. Lu, P. Campbell, and R. Salovey
Effect of Sterilization Method and Other Modifications on the Wear Resistance of Acetabular Cups Made of Ultra-High Molecular Weight Polyethylene : A Hip-Simulator Study
J. Bone Joint Surg. Am.,
December 1, 2000;
82(12):
1708 - 1708.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
G. LEWIS
Commentary - Design Issues in Clinical Studies of the in Vivo Volumetric Wear Rate of Polyethylene Bearing Components
J. Bone Joint Surg. Am.,
February 1, 2000;
82(2):
281 - 87.
[Full Text]
|
 |
|

|
 |

|
 |
 
T. P. SCHMALZRIED and J. J. CALLAGHAN
Current Concepts Review - Wear in Total Hip and Knee Replacements
J. Bone Joint Surg. Am.,
January 1, 1999;
81(1):
115 - 136.
[Full Text]
|
 |
|

|
 |

|
 |
 
T. P. SCHMALZRIED, F. J. DOREY, and H. MCKELLOP
The Multifactorial Nature of Polyethylene Wear in Vivo
J. Bone Joint Surg. Am.,
August 1, 1998;
80(8):
1234 - 42.
[Full Text]
|
 |
|
|