This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow Rights and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by TOBY, E. B.
Right arrow Articles by JAYARAMAN, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by TOBY, E. B.
Right arrow Articles by JAYARAMAN, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Facebook   Add to Technorati   Add to Twitter  
What's this?
The Journal of Bone and Joint Surgery 79:1190-7 (1997)
© 1997 The Journal of Bone and Joint Surgery, Inc.

A Comparison of Fixation Screws for the Scaphoid during Application of Cyclical Bending Loads*

E. B. TOBY, M.D.{dagger}, T. E. BUTLER, M.D.{dagger}, T. J. McCORMACK, M.D.{dagger} and G. JAYARAMAN, PH.D.{dagger}, KANSAS CITY, KANSAS

Investigation performed at The University of Kansas Medical Center, Kansas City

Matched pairs of scaphoids from cadavera were stressed with ramped intensity cyclical bending loads after osteotomy and fixation of one scaphoid with a Herbert screw and fixation of the other with an AO 3.5-millimeter cannulated screw, a Herbert-Whipple screw, an Acutrak cannulated screw, or a Universal Compression screw. The AO screw, Acutrak screw, and Herbert-Whipple screw demonstrated superior resistance to cyclical bending loads compared with the Herbert screw. The Universal Compression screw did not provide better fixation than the Herbert screw because of fractures that occurred at the time of insertion. The AO screw and the Herbert screw were then tested in a separate setup in which a segment of volar cortex had been removed in addition to the simple osteotomy. The loss of volar cortex greatly diminished the quality of the fixation provided by both of the screws during application of ramped intensity cyclical bending loads. CLINICAL RELEVANCE: A fixation device in the scaphoid must be able to withstand the stresses that are placed on the scaphoid as a result of its position spanning the proximal and distal carpal rows. Also, because of the prolonged time required for healing of fractures or non-unions of the scaphoid, the device must be able to withstand many such cycles of stress. The present study demonstrates that commonly used screws for fixation of the scaphoid vary significantly (p < 0.005) in their ability to resist cyclical bending loads.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Facebook Facebook   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
J Am Acad Orthop SurgHome page
A. P. Gutow
Percutaneous Fixation of Scaphoid Fractures
J. Am. Acad. Ortho. Surg., August 1, 2007; 15(8): 474 - 485.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
T. Waitayawinyu, W. V. McCallister, N. M. Nemechek, and T. E. Trumble
Scaphoid Nonunion
J. Am. Acad. Ortho. Surg., May 1, 2007; 15(5): 308 - 320.
[Full Text] [PDF]


Home page
JBJSHome page
J. M. Haisman, R. S. Rohde, and A. J. Weiland
Acute Fractures of the Scaphoid
J. Bone Joint Surg. Am., December 1, 2006; 88(12): 2750 - 2758.
[Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
T. E. Trumble, P. Salas, T. Barthel, and K. Q. Robert III
Management of Scaphoid Nonunions
J. Am. Acad. Ortho. Surg., November 1, 2003; 11(6): 380 - 391.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. F. Slade III, W. B. Geissler, A. P. Gutow, and G. A. Merrell
Percutaneous Internal Fixation of Selected Scaphoid Nonunions with an Arthroscopically Assisted Dorsal Approach
J. Bone Joint Surg. Am., November 1, 2003; 85(90004): 20 - 32.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
W. V. McCallister, J. Knight, R. Kaliappan, and T. E. Trumble
Central Placement of the Screw in Simulated Fractures of the Scaphoid Waist: A Biomechanical Study
J. Bone Joint Surg. Am., January 17, 2003; 85(1): 72 - 77.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. F. Slade III, A. P. Gutow, and W. B. Geissler
Percutaneous Internal Fixation of Scaphoid Fracturesvia an Arthroscopically Assisted Dorsal Approach
J. Bone Joint Surg. Am., November 25, 2002; 84 (suppl_2): S21 - S36.
[Abstract] [Full Text] [PDF]