This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow Rights and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BLOEBAUM, R. D.
Right arrow Articles by DORR, L. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by BLOEBAUM, R. D.
Right arrow Articles by DORR, L. D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Facebook   Add to Technorati   Add to Twitter  
What's this?
The Journal of Bone and Joint Surgery 79:1013-22 (1997)
© 1997 The Journal of Bone and Joint Surgery, Inc.

Postmortem Analysis of Bone Growth into Porous-Coated Acetabular Components*

ROY D. BLOEBAUM, PH.D.{dagger}, NIKKI L. MIHALOPOULUS, B.S.{dagger}, JENNIFER W. JENSEN, B.S.{dagger} and LAWRENCE D. DORR, M.D.{ddagger}, SALT LAKE CITY, UTAH

Investigation performed at the Bone and Joint Research Laboratory, Veterans Administration Medical Center, Salt Lake City

Microradiography, backscattered electron microscopy, and histological analysis were used to conduct a quantitative postmortem study of seven consecutively retrieved anatomical porous replacement acetabular components that had been inserted during total hip arthroplasties. Screws had been used for the initial fixation of six components. The microradiographic analysis of all seven components showed that an average (and standard deviation) of 84 ± 9 per cent (range, 72 to 93 per cent) of the porous coating was in direct apposition to the periprosthetic bone. The backscattered electron images demonstrated that an average of 12 ± 6 per cent (range, 4 to 21 per cent) of the space available in the porous coating was occupied by ingrown bone. The amount of bone ingrowth was not significantly different among the three zones delineated by DeLee and Charnley. Uniformity of bone growth into the porous coating suggests that the preferential loading that occurs in the superior region did not differentially affect the bone ingrowth. The present study showed that consistent bone growth into anatomical porous replacement acetabular components can be achieved.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Facebook Facebook   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
C. G. Christiansen, R. A. Kassim, J. J. Callaghan, J. L. Marsh, and A. H. Schmidt
Pubic Ramus Insufficiency Fractures Following Total Hip Arthroplasty: A Report of Six Cases
J. Bone Joint Surg. Am., September 1, 2003; 85(9): 1819 - 1822.
[Full Text] [PDF]


Home page
JBJSHome page
P. Udomkiat, Z. Wan, and L. D. Dorr
Comparison of Preoperative Radiographs and Intraoperative Findings of Fixation of Hemispheric Porous-Coated Sockets
J. Bone Joint Surg. Am., December 1, 2001; 83(12): 1865 - 1870.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. Bellemans, R. D. Bloebaum, J. W. Jensen, A. A. Hofmann, K. N. Bachus, and D. F. Scott
Correspondence
J. Bone Joint Surg. Am., November 1, 1998; 80(11): 1710 - 1710.
[Full Text]


Home page
JBJSHome page
R. D. BLOEBAUM, K. N. BACHUS, J. W. JENSEN, D. F. SCOTT, and A. A. HOFMANN
Porous-Coated Metal-Backed Patellar Components in Total Knee Replacement. A Postmortem Retrieval Analysis
J. Bone Joint Surg. Am., April 1, 1998; 80(4): 518 - 28.
[Abstract] [Full Text]