This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Related articles in JBJS
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by RANAWAT, C. S.
Right arrow Articles by RODRIGUEZ, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by RANAWAT, C. S.
Right arrow Articles by RODRIGUEZ, J. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 79:342-8 (1997)
© 1997 The Journal of Bone and Joint Surgery, Inc.

The Press-Fit Condylar Modular Total Knee System. Four-to-Six-Year Results with a Posterior-Cruciate-Substituting Design*

CHITRANJAN S. RANAWAT, M.D.{dagger}, CHRISTIAN P. LUESSENHOP, M.D.{ddagger} and JOSÉ A. RODRIGUEZ, M.D.{dagger}, NEW YORK, N.Y.

Investigation performed at the Center for Total Joint Replacement, Lenox Hill Hospital, New York City

One hundred and eighteen patients who had had 150 consecutive primary total knee replacements (sixteen bilateral procedures) between February 1988 and February 1990, with insertion of the press-fit condylar modular total knee system with cement, were enrolled in a prospective study. Ninety-six patients (125 knees) were followed for an adequate interval (mean, 4.8 years; range, 3.8 to 6.2 years). Thirteen patients (fifteen knees) died, and nine patients (ten knees) were lost to follow-up. The mean age of the patients at the time of the index arthroplasty was seventy years (range, twenty-nine to eighty-five years). The patients were evaluated clinically and radiographically, according to the scoring system of the Knee Society, and the results on a self-administered questionnaire were used to evaluate pain, function, satisfaction, and patellofemoral symptoms. A Kaplan-Meier survivorship analysis was performed with a revision operation as the end point. The mean functional and clinical scores, according to the system of the Knee Society, were 78 and 93 points, respectively, at the most recent follow-up examination. The result was excellent for 103 knees, good for thirteen, fair for three, and poor for six. Three revision operations were necessary: two because of infection and one because of instability. The over-all rate of patellofemoral symptoms was 8 per cent (ten knees). Three knees had tibiofemoral instability; subsequent modification of the design of the tibial cam decreased the prevalence of this problem. Non-progressive radiolucent lines were present at the cement-bone interface in 39 per cent (thirty-nine) of the ninety-nine knees that had complete radiographic follow-up. No prosthesis had loosened by the time of the most recent follow-up examination. The rate of survival of the implant was 97 per cent at six years, and the standard error of the mean was 1.6 per cent. In the present series, total knee arthroplasties with the press-fit condylar modular knee system resulted in excellent relief of pain, an excellent range of motion, and restoration of function. They were also associated with a low prevalence of patellofemoral problems.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?

Related articles in JBJS:

The Press-Fit Condylar Modular Total Knee System with a Posterior Cruciate-Substituting Design A Concise Follow-up of a Previous Report
V.J. Rasquinha, C.S. Ranawat, C.L. Cervieri, and J.A. Rodriguez
JBJS 2006 88: 1006-1010. [Abstract] [Full Text]  



This article has been cited by other articles:


Home page
JBJSHome page
D. J. Rodricks, S. Patil, P. Pulido, and C. W. Colwell Jr.
Press-Fit Condylar Design Total Knee Arthroplasty. Fourteen to Seventeen-Year Follow-up
J. Bone Joint Surg. Am., January 1, 2007; 89(1): 89 - 95.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
V.J. Rasquinha, C.S. Ranawat, C.L. Cervieri, and J.A. Rodriguez
The Press-Fit Condylar Modular Total Knee System with a Posterior Cruciate-Substituting Design A Concise Follow-up of a Previous Report
J. Bone Joint Surg. Am., May 1, 2006; 88(5): 1006 - 1010.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
G. Li, E. Most, P. G. Sultan, S. Schule, S. Zayontz, S. E. Park, and H. E. Rubash
Knee Kinematics with a High-Flexion Posterior Stabilized Total Knee Prosthesis: An in Vitro Robotic Experimental Investigation
J. Bone Joint Surg. Am., August 1, 2004; 86(8): 1721 - 1729.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. W. Pagnano, G. R. Scuderi, and J. N. Insall
Tibial Osteolysis Associated with the Modular Tibial Tray of a Cemented Posterior Stabilized Total Knee Replacement : A Case Report
J. Bone Joint Surg. Am., October 1, 2001; 83(10): 1545 - 1548.
[Full Text] [PDF]


Home page
JBJSHome page
S. A. Mikulak, O. M. Mahoney, M. A. delaRosa, and T. P. Schmalzried
Loosening and Osteolysis with the Press-Fit Condylar Posterior-Cruciate-Substituting Total Knee Replacement
J. Bone Joint Surg. Am., March 1, 2001; 83(3): 398 - 398.
[Abstract] [Full Text]


Home page
JBJSHome page
M. Akagi, T. Nakamura, Y. Matsusue, T. Ueo, K. Nishijyo, and E. Ohnishi
The Bisurface Total Knee Replacement: A Unique Design for Flexion : Four-to-Nine-Year Follow-up Study
J. Bone Joint Surg. Am., November 1, 2000; 82(11): 1626 - 1626.
[Abstract] [Full Text]


Home page
JBJSHome page
J. J. Callaghan, M. W. Squire, D. D. Goetz, P. M. Sullivan, and R. C. Johnston
Cemented Rotating-Platform Total Knee Replacement : A Nine to Twelve-Year Follow-up Study
J. Bone Joint Surg. Am., May 1, 2000; 82(5): 705 - 705.
[Abstract] [Full Text]