This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by KOBAYASHI, S.
Right arrow Articles by HISA, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by KOBAYASHI, S.
Right arrow Articles by HISA, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 79:1618-1627 (1997)
© 1997 The Journal of Bone and Joint Surgery, Inc.

Factors Affecting Aseptic Failure of Fixation after Primary Charnley Total Hip Arthroplasty. Multivariate Survival Analysis*

SENEKI KOBAYASHI, M.D., PH.D.{dagger}, KUNIO TAKAOKA, M.D., PH.D.{dagger}, NAOTO SAITO, M.D., PH.D.{dagger} and KENJI HISA, M.D.{dagger}, MATSUMOTO, JAPAN

Investigation performed at the Department of Orthopaedic Surgery, Shinshu University School of Medicine, Matsumoto

Multivariate survival analysis with use of the Cox proportional-hazards model was applied to a consecutive series of 293 primary Charnley total hip arthroplasties performed on 246 patients. The purpose of the analysis was to identify risk factors for, and to quantitate their effects on, aseptic failure of fixation. The duration of follow-up ranged from one month to twenty-three years (average, thirteen years). The end point of survival was defined as radiographic evidence of failure of fixation or as a revision operation. Failure of fixation of the acetabular component was defined as complete demarcation or migration. Failure of the femoral component was defined as progression of at least one of five postoperative signs (subsidence, demarcation of the cement, separation of the component from the cement, fracture of the cement, and endosteal cavitation) or as the occurrence of at least two of these signs. Twenty-four specific items of data for each acetabular component and thirty specific items for each femoral component formed the sets of variables for the analysis. With use of radiographic evidence of failure as the end point, the sixteen-year rates of survival (with 95 per cent confidence interval) were 83.6 ± 5.6 per cent for the acetabular components and 90.9 ± 4.1 per cent for the femoral components. With use of revision as the end point, the sixteen-year rates of survival were 92.3 ± 4.0 per cent and 95.6 ± 3.2 per cent, respectively. The most important risk factor affecting radiographic loosening of the acetabular component was rapid wear of the polyethylene (0.2 millimeter or more annually), followed by the classification of the osteoarthrosis (as hypertrophic, normotrophic, or atrophic) according to the extent of osteophyte formation. The sockets in the hips that had hypertrophic osteoarthrosis survived longer than those in the other two groups. Survival of the acetabular component as determined on the basis of revision was affected only by rapid wear of the polyethylene. Survival of the femoral component, with either radiographic failure of fixation or revision as the end point, was affected by an unfavorable geometry of the medullary canal (a so-called stovepipe canal or a large canal). Patients who have rapid wear of the polyethylene, little osteophyte formation, or an unfavorable geometry of the canal should be followed carefully. These risk factors warrant additional evaluation.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
D. H. Sochart, K. F. Orishimo, A. M. Claus, C. J. Sychterz, and C. A. Engh Sr.
Relationship Between Polyethylene Wear and Osteolysis in Hips with a Second-Generation Porous-Coated Cementless Cup * K.F. Orishimo, A.M. Claus, C.J. Sychterz, and C.A. Engh Sr. reply:
J. Bone Joint Surg. Am., May 1, 2004; 86(5): 1099 - 1099.
[Full Text] [PDF]


Home page
JBJSHome page
S. Kobayashi, N. Saito, M. Nawata, H. Horiuchi, R. Iorio, and K. Takaoka
Total Hip Arthroplasty with Bulk Femoral Head Autograft for Acetabular Reconstruction in Developmental Dysplasia of the Hip
J. Bone Joint Surg. Am., March 31, 2003; 85(4): 615 - 621.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. Hamadouche, P. Boutin, J. Daussange, M. E. Bolander, and L. Sedel
Alumina-on-Alumina Total Hip Arthroplasty : A Minimum 18.5-Year Follow-up Study
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 69 - 77.
[Abstract] [Full Text]


Home page
JBJSHome page
B. R. Hamlin, C. Rowland, and B. F. Morrey
Retention of All-Polyethylene Acetabular Components After Femoral Revision of a Cemented Total Hip Replacement
J. Bone Joint Surg. Am., November 1, 2001; 83(11): 1700 - 1705.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
D. H. Sochart, J. E. Dowd, C. J. Sychterz, A. M. Young, and C. A. Engh
True Wear Rates as Predictors of Risk for Osteolysis After Total Hip Arthroplasty
J. Bone Joint Surg. Am., August 1, 2001; 83(8): 1277 - 1277.
[Full Text]


Home page
ptjournalHome page
D. A Neumann
An Electromyographic Study of the Hip Abductor Muscles as Subjects With a Hip Prosthesis Walked With Different Methods of Using a Cane and Carrying a Load
Physical Therapy, December 1, 1999; 79(12): 1163 - 1176.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
T. P. SCHMALZRIED and J. J. CALLAGHAN
Current Concepts Review - Wear in Total Hip and Knee Replacements
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 115 - 136.
[Full Text]