This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow Rights and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by GARINO, J. P.
Right arrow Articles by STEINBERG, M. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by GARINO, J. P.
Right arrow Articles by STEINBERG, M. E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Facebook   Add to Technorati   Add to Twitter  
What's this?
The Journal of Bone and Joint Surgery 78:1359-65 (1996)
© 1996 The Journal of Bone and Joint Surgery, Inc.

Deep Venous Thrombosis after Total Joint Arthroplasty. The Role of Compression Ultrasonography and the Importance of the Experience of the Technician*

JONATHAN P. GARINO, M.D.{dagger}, PAUL A. LOTKE, M.D.{dagger}, KURT J. KITZIGER, M.D.{ddagger} and MARVIN E. STEINBERG, M.D.{dagger}, PHILADELPHIA, PENNSYLVANIA

Investigation performed at the Department of Orthopaedic Surgery, Hospital of the University of Pennsylvania, Philadelphia

We evaluated the influence of the expertise of the technician on the accuracy of compression ultrasonography as a screening test to detect postoperative deep venous thrombosis in patients who had had primary or revision arthroplasty of the hip or the knee. The study was performed in two phases on two groups of patients who were evaluated with both compression ultrasonography and conventional venography. All of the patients received prophylaxis for deep venous thrombosis. In the first phase of the study, adequate venograms and ultrasonograms were made for 126 extremities (121 patients). Venography demonstrated seven thrombi in the proximal veins. Only three ultrasonograms were considered positive. Ultrasonography had a sensitivity of 0 per cent because none of the seven proximal thrombi identified with venography were detected with ultrasonography. Three ultrasonograms were false-positive (that is, the ultrasonogram was positive and the venogram was negative), so the specificity was 97 per cent. The accuracy of compression ultrasonography was 92 per cent. Both tests were performed on a second group of eighty-seven extremities (eighty-four patients). Proximal clots were detected with venography in five extremities. The ultrasonogram was positive for seven extremities, including the five in which a clot had been identified with venography. There were no false-negative and two false-positive results. In this phase of the study, ultrasonography had a sensitivity of 100 per cent, a specificity of 98 per cent, and an accuracy of 98 per cent. The only difference that was identified between the two groups of patients was the experience of the ultrasonography technician. It appears that the reliability of compression ultrasonography is directly dependent on the experience of the technician.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Facebook Facebook   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
J. R. Lieberman and W. K. Hsu
Prevention of Venous Thromboembolic Disease After Total Hip and Knee Arthroplasty
J. Bone Joint Surg. Am., September 1, 2005; 87(9): 2097 - 2112.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
W. H. Geerts, G. F. Pineo, J. A. Heit, D. Bergqvist, M. R. Lassen, C. W. Colwell, and J. G. Ray
Prevention of Venous Thromboembolism: The Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy
Chest, September 1, 2004; 126(3_suppl): 338S - 400S.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
J.-L. Cracowski, J.-L. Bosson, F. Baloul, C. Moirant, M. Hunt, P. Merloz, P. Carpentier, and A. Franco
Early development of deep-vein thrombosis following hip fracture surgery: the role of venous wall thickening detected by B-mode ultrasonography
Vascular Medicine, November 1, 1998; 3(4): 269 - 274.
[Abstract] [PDF]


Home page
JBJSHome page
W. J. CICCONE, P. S. FOX, M. NEUMYER, D. RUBENS, W. M. PARRISH, and V. D. PELLEGRINI
Ultrasound Surveillance for Asymptomatic Deep Venous Thrombosis after Total Joint Replacement
J. Bone Joint Surg. Am., August 1, 1998; 80(8): 1167 - 74.
[Abstract] [Full Text]


Home page
JBJSHome page
J. BERNSTEIN
Current Concepts Review - Decision Analysis
J. Bone Joint Surg. Am., September 1, 1997; 79(9): 1404 - 14.
[Full Text]