This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MULDOON, L. C. M. P.
Right arrow Articles by MELILLO, L. C. A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MULDOON, L. C. M. P.
Right arrow Articles by MELILLO, L. C. A. S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?
The Journal of Bone and Joint Surgery 78:1486-90 (1996)
© 1996 The Journal of Bone and Joint Surgery, Inc.

Failure of a Non-Porous-Coated Acetabular Component Inserted without Cement in Primary Total Hip Arthroplasty*{dagger}

LIEUTENANT COMMANDER MICHAEL P. MULDOON, {ddagger}, MEDICAL CORPS, DOUGLAS E. PADGETT, M.D.§, SAN DIEGO, LIEUTENANT ROBERTA ROTHEN, {ddagger}MEDICAL CORPS,UNITED STATES NAVY, GERALD W. CADY, M.D.{ddagger},SAN DIEGO,CALIFORNIA and LIEUTENANT COMMANDER ANTHONY S. MELILLO, {ddagger},MEDICAL CORPS,UNITED STATES NAVAL RESERVE

Investigation performed at the Departments of Orthopedics and Clinical Investigation, Naval Medical Center, San Diego

Thirty-four patients (thirty-eight hips) had a primary total hip arthroplasty with insertion of a non-porous-coated titanium-alloy acetabular component without cement. This component is initially stabilized with use of a central acetabular polyethylene peg, which is inserted into the pelvis, as well as supplementary cortical-bone screws inserted into the ilium. The original diagnosis was degenerative joint disease in thirty-four hips and avascular necrosis in four hips. Twenty-five femoral components were inserted with cement, and thirteen non-porous-coated femoral implants were inserted without cement. The acetabulum was prepared with so-called line-to-line reaming. Thirty-five hips in thirty-one patients were available for clinical and radiographic follow-up at a mean of 4.5 years (range, two to seven years). Serial measurements of the position of the acetabular component revealed that eighteen cups (51 per cent) had migrated. Of these, eleven had been revised. Radiolucent lines of at least one millimeter in thickness at the bone-prosthesis interface were noted adjacent to all but six of the acetabular components. Although this series was small, it demonstrates an unacceptably high rate of failure of non-porous-coated acetabular components after a relatively short duration. We question the efficacy of this acetabular component, inserted without cement, as part of a primary total hip arthroplasty.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?