This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Alman, B. A.
Right arrow Articles by Hubbard, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Alman, B. A.
Right arrow Articles by Hubbard, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 77, Issue 12 1876-1882, Copyright © 1995 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Proximal femoral focal deficiency: results of rotationplasty and Syme amputation

BA Alman, JI Krajbich and S Hubbard
Hugh MacMillan Rehabilitation Centre, Toronto, Ontario, Canada.

We reviewed the results of treatment of sixteen patients who had had an isolated unilateral proximal femoral focal deficiency; nine were managed with a rotationplasty and seven, with a Syme amputation combined with an arthrodesis of the knee. We evaluated the perceived physical appearance, gross motor function, and metabolic energy expended in walking. The mean duration of follow-up was 9.9 years (range, four to fourteen years). The mean age of the patients at the time of the study was 13.9 years (range, eight to 18.4 years) in the rotationplasty group and 14.8 years (range, 9.5 to 19.9 years) in the Syme-amputation group. There were three female patients in each group. Roentgenograms showed that the femoral head was in the acetabulum (Aitken class A or B) in four of the seven patients in the Syme-amputation group and in five of the nine patients in the rotationplasty group; the remaining patients did not have this finding (Aitken class C or D). There was no difference in gross motor function or perceived physical appearance between the groups. Rotationplasty was associated with a more energy-efficient gait (mean, 0.153 milliliter of oxygen per kilogram-meter [range, 0.128 to 0.173 milliliter of oxygen per kilogram-meter] than was Syme amputation (mean, 0.169 milliliter of oxygen per kilogram-meter [range, 0.151 to 0.182 milliliter of oxygen per kilogram-meter]). Both types of treatment resulted in a net oxygen utilization per distance (efficiency) that was less than the values reported after amputations performed for non-congenital disorders.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
K. L.B. Brown
Resection, Rotationplasty, and Femoropelvic Arthrodesis in Severe Congenital Femoral Deficiency : A Report of the Surgical Technique and Three Cases
J. Bone Joint Surg. Am., January 1, 2001; 83(1): 78 - 78.
[Abstract] [Full Text]