This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Havelin, L. I.
Right arrow Articles by Engesaeter, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Havelin, L. I.
Right arrow Articles by Engesaeter, L. B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 77, Issue 10 1543-1550, Copyright © 1995 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The effect of the type of cement on early revision of Charnley total hip prostheses. A review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register

LI Havelin, B Espehaug, SE Vollset and LB Engesaeter
Department of Orthopaedics and Traumatology, Haukeland University Hospital, Bergen, Norway.

We studied the survival of 8579 Charnley prostheses, in 7922 patients, according to the different types of cement that had been used. All of the patients had had a primary total hip replacement for primary coxarthrosis. The mean duration of follow-up was 3.2 years (range, zero to 6.4 years). The data were collected from the national Norwegian Arthroplasty Register. The duration of survival was defined as the time to revision due to aseptic loosening. The Kaplan-Meier estimate of survival at 5.5 years for the 1226 femoral components that had been implanted with low-viscosity cement was 94.1 per cent (95 per cent confidence interval, 92.1 to 96.2 per cent), compared with 98.1 per cent (95 per cent confidence interval, 97.5 to 98.6 per cent) for the 6589 components that had been implanted with high-viscosity cement (p < 0.0001). The remaining 764 femoral components had been implanted with Boneloc cement, which was classified as neither high nor low-viscosity, and these components were considered as a separate group in the analyses. The Boneloc cement had been used for only three years, and the two-year survival rate of these prostheses was 95.5 per cent (p < 0.0001). The cement contained an antibiotic in 2801 (42 per cent of the hips in which the femoral component had been implanted with high-viscosity cement, compared with only thirty (2 per cent) of those in which it had been implanted with low-viscosity cement.(ABSTRACT TRUNCATED AT 250 WORDS)
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am J Sports MedHome page
L.-P. Granan, R. Bahr, K. Steindal, O. Furnes, and L. Engebretsen
Development of a National Cruciate Ligament Surgery Registry: The Norwegian National Knee Ligament Registry
Am. J. Sports Med., February 1, 2008; 36(2): 308 - 315.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
T. W. Bauer, J. Parvizi, N. Kobayashi, and V. Krebs
Diagnosis of Periprosthetic Infection
J. Bone Joint Surg. Am., April 1, 2006; 88(4): 869 - 882.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
E. H. Yian, C. M.L. Werner, R. W. Nyffeler, C. W. Pfirrmann, A. Ramappa, A. Sukthankar, and C. Gerber
Radiographic and Computed Tomography Analysis of Cemented Pegged Polyethylene Glenoid Components in Total Shoulder Replacement
J. Bone Joint Surg. Am., September 1, 2005; 87(9): 1928 - 1936.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
N. P. Walton, C. Darrah, L. Shepstone, S. T. Donell, and H. Phillips
The Elite Plus total hip arthroplasty: THE NEED FOR RADIOLOGICAL SURVEILLANCE
J Bone Joint Surg Br, April 1, 2005; 87-B(4): 458 - 462.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
S. KOBAYASHI, K. TAKAOKA, N. SAITO, and K. HISA
Factors Affecting Aseptic Failure of Fixation after Primary Charnley Total Hip Arthroplasty. Multivariate Survival Analysis
J. Bone Joint Surg. Am., November 1, 1997; 79(11): 1618 - 1627.
[Abstract] [Full Text]