This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ballard, W. T.
Right arrow Articles by Johnston, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ballard, W. T.
Right arrow Articles by Johnston, R. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 76, Issue 7 959-964, Copyright © 1994 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old. A ten-year follow-up study

WT Ballard, JJ Callaghan, PM Sullivan and RC Johnston
Iowa Methodist Medical Center, Des Moines.

Thirty-six patients (forty-two hips) in whom so-called second-generation cementing techniques, such as medullary lavage, use of an intramedullary cement plug, hand-mixing of the cement, and use of a cement gun to deliver the cement in a doughy state in a retrograde fashion, had been used for a primary total hip arthroplasty were evaluated at an average of eleven years (range, ten to fifteen years) after the operation. All of the patients had been less than fifty years old at the time of the operation. Thirty-one patients were evaluated by clinical and radiographic examinations and five, by a telephone interview. Twelve components (ten acetabular components [24 per cent] and two femoral components [5 per cent]) in ten hips had been revised for aseptic loosening. An additional five acetabular components (12 per cent) and five femoral components were definitely loose according to radiographic criteria. Three of these femoral components were polished stems that were considered loose only because of the presence of a radiolucent line, 0.5, one, and two millimeters wide, at the prosthesis-cement interface in zone 1 of Gruen et al. The other two loose stems were in patients who were receiving renal dialysis. These findings demonstrate excellent fixation of the femoral component but continued problems with fixation of the acetabular component despite the use of improved cementing techniques.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
R. J. Sierra, R. T. Trousdale, and M. E. Cabanela
Pregnancy and childbirth after total hip arthroplasty
J Bone Joint Surg Br, January 1, 2005; 87-B(1): 21 - 24.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
B. W. Schreurs, V. J.J.F. Busch, M. L. Welten, N. Verdonschot, T. J.J.H. Slooff, and J. W.M. Gardeniers
Acetabular Reconstruction with Impaction Bone-Grafting and a Cemented Cup in Patients Younger Than Fifty Years Old
J. Bone Joint Surg. Am., November 1, 2004; 86(11): 2385 - 2392.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. D. Crowther and P. F. Lachiewicz
Survival and Polyethylene Wear of Porous-Coated Acetabular Components in Patients Less than Fifty Years Old : Results at Nine to Fourteen Years
J. Bone Joint Surg. Am., May 1, 2002; 84(5): 729 - 735.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
D. K. Collis and C. G. Mohler
Comparison of Clinical Outcomes in Total Hip Arthroplasty Using Rough and Polished Cemented Stems with Essentially the Same Geometry
J. Bone Joint Surg. Am., April 1, 2002; 84(4): 586 - 592.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. G. CREIGHTON, J. J. CALLAGHAN, J. P. OLEJNICZAK, and R. C. JOHNSTON
Total Hip Arthroplasty with Cement in Patients Who Have Rheumatoid Arthritis. A Minimum Ten-Year Follow-up Study
J. Bone Joint Surg. Am., October 1, 1998; 80(10): 1439 - 46.
[Abstract] [Full Text]


Home page
JBJSHome page
J. J. CALLAGHAN, E. E. FOREST, J. P. OLEJNICZAK, D. D. GOETZ, and R. C. JOHNSTON
Charnley Total Hip Arthroplasty in Patients Less Than Fifty Years Old. A Twenty to Twenty-five-Year Follow-up Note
J. Bone Joint Surg. Am., May 1, 1998; 80(5): 704 - 14.
[Abstract] [Full Text]


Home page
JBJSHome page
E. GARCÍA-CIMBRELO, V. DIEZ-VAZQUEZ, R. MADERO, and L. MUNUERA
Progression of Radiolucent Lines Adjacent to the Acetabular Component and Factors Influencing Migration after Charnley Low-Friction Total Hip Arthroplasty*{{dagger}}
J. Bone Joint Surg. Am., September 1, 1997; 79(9): 1373 - 80.
[Abstract] [Full Text]


Home page
JBJSHome page
W. N. CAPELLO, J. A. D'ANTONIO, J. R. FEINBERG, and M. T. MANLEY
Hydroxyapatite-Coated Total Hip Femoral Components in Patients Less Than Fifty Years Old. Clinical and Radiographic Results after Five to Eight Years of Follow-up
J. Bone Joint Surg. Am., July 1, 1997; 79(7): 1023 - 9.
[Abstract] [Full Text]


Home page
JBJSHome page
M. J. CHMELL, R. D. SCOTT, W. H. THOMAS, and C. B. SLEDGE
Total Hip Arthroplasty with Cement for Juvenile Rheumatoid Arthritis. Results at a Minimum of Ten Years in Patients Less Than Thirty Years Old
J. Bone Joint Surg. Am., January 1, 1997; 79(1): 44 - 52.
[Abstract] [Full Text]


Home page
JBJSHome page
S. M. MADEY, J. J. CALLAGHAN, J. P. OLEJNICZAK, D. D. GOETZ, and R. C. JOHNSTON
Charnley Total Hip Arthroplasty with Use of Improved Techniques of Cementing. The Results after a Minimum of Fifteen Years of Follow-up
J. Bone Joint Surg. Am., January 1, 1997; 79(1): 53 - 64.
[Abstract] [Full Text]


Home page
JBJSHome page
V. V. RAUT, P. D. SINEY, and B. M. WROBLEWSKI
Revision of the Acetabular Component of a Total Hip Arthroplasty with Cement in Young Patients without Rheumatoid Arthritis
J. Bone Joint Surg. Am., December 1, 1996; 78(12): 1853 - 6.
[Abstract] [Full Text]


Home page
JBJSHome page
H. A. LATIMER and P. F. LACHIEWICZ
Porous-Coated Acetabular Components with Screw Fixation. Five to Ten-Year Results
J. Bone Joint Surg. Am., July 1, 1996; 78(7): 975 - 81.
[Abstract] [Full Text]


Home page
JBJSHome page
K. L. WEBER, J. J. CALLAGHAN, D. D. GOETZ, and R. C. JOHNSTON
Revision of a Failed Cemented Total Hip Prosthesis with Insertion of an Acetabular Component without Cement and a Femoral Component with Cement. A Five to Eight-Year Follow-up Study
J. Bone Joint Surg. Am., July 1, 1996; 78(7): 982 - 94.
[Abstract] [Full Text]