This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmalzried, T. P.
Right arrow Articles by Amstutz, H. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmalzried, T. P.
Right arrow Articles by Amstutz, H. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 76, Issue 5 677-688, Copyright © 1994 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis

TP Schmalzried, D Guttmann, M Grecula and HC Amstutz
Joint Replacement Institute, Los Angeles, California 90007.

Between 1983 and 1987, an acetabular component with a unique chamfered-cylinder design was inserted without cement in 134 hips. With use of this design, initial stability is achieved through a cylindrical interference fit with the peripheral rim of the acetabulum, without the need for pegs, spikes, or screws. At an average of sixty-four months (range, forty to ninety-six months) after implantation, follow-up data were available for 113 hips (ninety-three patients). No component had been revised for loosening or was radiographically loose. However, the prevalence of balloon-like osteolysis of the pelvis was 17 per cent (nineteen hips). This bone loss was generally not associated with pain or other symptoms. Ten of the nineteen hips that were associated with pelvic osteolysis (including six of the nine that were associated with osteolysis of the ilium) had been reconstructed with use of an acetabular component that had no holes in the shell (that is, the shell was completely solid). This finding indicates that, while elimination of holes through the acetabular shell may have advantages, it will not prevent pelvic osteolysis. The osteolysis of the ilium was associated with a lateral opening of the acetabular component of more than 50 degrees (p < 0.0001). All of the hips in this series had insertion of a porous-ingrowth femoral resurfacing component made of titanium alloy. These components are no longer used. Revision of the femoral side due to osteolysis provided a unique opportunity to inspect directly forty-two clinically well functioning acetabular components. All of the polyethylene liners and acetabular shells were found to be rigidly fixed. Inflammatory tissue at the periphery of the implant-bone interface resulted in circumferential resorption of periacetabular bone despite rigid fixation of the component. This is direct evidence that a process of bone resorption similar to that reported at the cement-bone interface of cemented acetabular components can occur at the implant-bone interface of components inserted without cement. At the reoperation, a communication that had led to the pelvic osteolysis was found through areas of bone resorption at the periphery of the implant-bone interface. These areas were essentially cystic and were filled with a mixture of fluid and friable, yellow-tan tissue. It appeared that the osteolytic process had expanded into the soft cancellous bone and marrow while being contained by the denser cortical shell of the pelvic bones.(ABSTRACT TRUNCATED AT 250 WORDS)
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
F.H.R. De Man, W. Tigchelaar, R.K. Marti, C.J.F. Van Noorden, and H.M. Van der Vis
Effects of Mechanical Compression of a Fibrous Tissue Interface on Bone with or without High-Density Polyethylene Particles in a Rabbit Model of Prosthetic Loosening
J. Bone Joint Surg. Am., July 1, 2005; 87(7): 1522 - 1533.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
Y.-G. Kim, S.-Y. Kim, S.-J. Kim, B.-C. Park, P.-T. Kim, and J.-C. Ihn
The use of cementless expansion acetabular component and an alumina-polyethylene bearing in total hip arthroplasty for osteonecrosis
J Bone Joint Surg Br, June 1, 2005; 87-B(6): 776 - 780.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. Heisel, M. Silva, M. A. dela Rosa, and T. P. Schmalzried
Short-Term in Vivo Wear of Cross-Linked Polyethylene
J. Bone Joint Surg. Am., April 1, 2004; 86(4): 748 - 751.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. Heisel, M. Silva, and T. P. Schmalzried
Bearing Surface Options for Total Hip Replacement in Young Patients
J. Bone Joint Surg. Am., July 3, 2003; 85(7): 1366 - 1379.
[Full Text] [PDF]


Home page
JBJSHome page
Y.-H. Kim, S.-H. Oh, J.-S. Kim, and K.-H. Koo
Contemporary Total Hip Arthroplasty with and without Cement in Patients with Osteonecrosis of the Femoral Head
J. Bone Joint Surg. Am., March 31, 2003; 85(4): 675 - 681.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
R. L. Barrack
Dislocation After Total Hip Arthroplasty: Implant Design and Orientation
J. Am. Acad. Ortho. Surg., March 1, 2003; 11(2): 89 - 99.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. Udomkiat, L. D. Dorr, and Z. Wan
Cementless Hemispheric Porous-Coated Sockets Implanted with Press-Fit Technique without Screws: Average Ten-Year Follow-up
J. Bone Joint Surg. Am., July 9, 2002; 84(7): 1195 - 1200.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. D. Crowther and P. F. Lachiewicz
Survival and Polyethylene Wear of Porous-Coated Acetabular Components in Patients Less than Fifty Years Old : Results at Nine to Fourteen Years
J. Bone Joint Surg. Am., May 1, 2002; 84(5): 729 - 735.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
R. Illgen II and H. E. Rubash
The Optimal Fixation of the Cementless Acetabular Component in Primary Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2002; 10(1): 43 - 56.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. M. Young, C. J. Sychterz, R. H. Hopper Jr., and C. A. Engh
Effect of Acetabular Modularity on Polyethylene Wear and Osteolysis in Total Hip Arthroplasty
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 58 - 63.
[Abstract] [Full Text]


Home page
JBJSHome page
J. E. Dowd, C. J. Sychterz, A. M. Young, and C. A. Engh
Characterization of Long-Term Femoral-Head-Penetration Rates : Association with and Prediction of Osteolysis
J. Bone Joint Surg. Am., August 1, 2000; 82(8): 1102 - 1102.
[Abstract] [Full Text]


Home page
JBJSHome page
K. D. MOORE, R. L. BARRACK, C. J. SYCHTERZ, J. SAWHNEY, A. M. YANG, and C. A. ENGH
The Effect of Weight-Bearing on the Radiographic Measurement of the Position of the Femoral Head After Total Hip Arthroplasty
J. Bone Joint Surg. Am., January 1, 2000; 82(1): 62 - 9.
[Abstract] [Full Text]


Home page
JBJSHome page
T. P. SCHMALZRIED and J. J. CALLAGHAN
Current Concepts Review - Wear in Total Hip and Knee Replacements
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 115 - 136.
[Full Text]


Home page
JBJSHome page
W. J. MALONEY, P. HERZWURM, W. PAPROSKY, H. E. RUBASH, and C. A. ENGH
Treatment of Pelvic Osteolysis Associated with a Stable Acetabular Component Inserted without Cement as Part of a Total Hip Replacement
J. Bone Joint Surg. Am., November 1, 1997; 79(11): 1628 - 34.
[Abstract] [Full Text]


Home page
JBJSHome page
J. M. MARTELL and S. BERDIA
Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs
J. Bone Joint Surg. Am., November 1, 1997; 79(11): 1635 - 41.
[Abstract] [Full Text]


Home page
JBJSHome page
G. S. TOMPKINS, J. J. JACOBS, L. R. KULL, A. G. ROSENBERG, and J. O. GALANTE
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. Seven-to-Ten-Year Results
J. Bone Joint Surg. Am., February 1, 1997; 79(2): 169 - 76.
[Abstract] [Full Text]


Home page
JBJSHome page
C. J. SYCHTERZ, K. H. MOON, Y. HASHIMOTO, K. M. TEREFENKO, C. A. ENGH JR., and T. W. BAUER
Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1193 - 1200.
[Abstract] [Full Text]