This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goulet, J. A.
Right arrow Articles by Goldstein, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goulet, J. A.
Right arrow Articles by Goldstein, S. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 76, Issue 10 1457-1463, Copyright © 1994 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Comminuted fractures of the posterior wall of the acetabulum. A biomechanical evaluation of fixation methods

JA Goulet, JP Rouleau, DJ Mason and SA Goldstein
Orthopaedic Research Laboratories, University of Michigan, Ann Arbor 48109.

Reproducible simple fractures and osteotomies of the posterior wall of the acetabulum were created in twenty paired hemipelves from fresh human cadavera. Comminution was created with an additional fracture line that was either parallel (concentric comminution) or perpendicular (transverse comminution) to the posterior rim of the acetabulum. Under simulated weight-bearing, the stiffness of fixation of the transversely comminuted fractures that had been achieved with use of a reconstruction plate and screws was significantly higher than that achieved with fixation with screws alone (p < 0.05). The load to failure of the fixation of transversely comminuted fractures treated with a reconstruction plate and screws was also significantly higher than that of fixation of such fractures with screws alone (p = 0.05). The load to failure of the fixation of concentrically comminuted fractures was significantly higher when a reconstruction plate and accessory spring plates had been used than when a reconstruction plate alone had been employed (p < 0.05).
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?