This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gilbert, J. L.
Right arrow Articles by Zernich, M. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gilbert, J. L.
Right arrow Articles by Zernich, M. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 76, Issue 1 110-115, Copyright © 1994 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants

JL Gilbert, CA Buckley, JJ Jacobs, KC Bertin and MR Zernich
Division of Biological Materials, Northwestern University, Chicago, Illinois 60611.

Two modular hip implants with a cobalt-alloy head and a cobalt-alloy stem were retrieved after a fracture had occurred in the neck region of the femoral component, eighty-five and seventy months after implantation. Both implants failed less than one millimeter distal to the taper junction between the head and the stem (outside of the taper). The fracture surfaces of the implant were investigated with the use of scanning electron microscopy, to determine the nature of the failure process. The fractures occurred at the grain boundaries of the microstructure and appeared to be the result of three factors: porosity at the grain boundaries; intergranular corrosive attack, initiated both at the head-neck taper and at the free surface; and cyclic fatigue-loading of the stem. The corrosive attack of the free surface was initiated, in part, by the egression of surface grains and by the ingression of fluid into the intergranular regions. Sectioned surfaces showed extensive intergranular corrosive attack in the prosthetic neck localized in the region of the head-neck taper junction and penetrating deeply into the microstructure.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
D. M. Jones, J. L. Marsh, J. V. Nepola, J. J. Jacobs, A. K. Skipor, R. M. Urban, J. L. Gilbert, and J. A. Buckwalter
Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail
J. Bone Joint Surg. Am., April 1, 2001; 83(4): 537 - 537.
[Abstract] [Full Text]


Home page
JBJSHome page
J. J. JACOBS, J. L. GILBERT, and R. M. URBAN
Current Concepts Review - Corrosion of Metal Orthopaedic Implants
J. Bone Joint Surg. Am., February 1, 1998; 80(2): 268 - 82.
[Full Text]


Home page
JBJSHome page
S. T. WOOLSON, J. P. MILBAUER, J. D. BOBYN, S. YUE, and W. J. MALONEY
Fatigue Fracture of a Forged Cobalt-Chromium-Molybdenum Femoral Component Inserted with Cement. A Report of Ten Cases
J. Bone Joint Surg. Am., December 1, 1997; 79(12): 1842 - 8.
[Abstract] [Full Text]