This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, T. D.
Right arrow Articles by Brand, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, T. D.
Right arrow Articles by Brand, R. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 75, Issue 9 1358-1367, Copyright © 1993 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Mechanical consequences of core drilling and bone-grafting on osteonecrosis of the femoral head

TD Brown, DR Pedersen, KJ Baker and RA Brand
Department of Orthopaedic Surgery, University of Iowa, Iowa City 52242-1008.

We employed an anatomically realistic three-dimensional finite-element model to explore several biomechanical variables involved in coring or bone-grafting of a segmentally necrotic femoral head. The mechanical efficacy of several variants of these procedures was indexed in terms of their alteration of the stress:strength ratio in at-risk necrotic cancellous bone. For coring alone, the associated structural compromise was generally modest, provided that the tract did not extend near the subchondral plate. Cortical bone-grafting was potentially of great structural benefit for femoral heads in which the graft penetrated deeply into the superocentral or lateral aspect of the lesion, ideally with abutment against the subchondral plate. By contrast, central or lateral grafts that stopped well short of the subchondral plate were contraindicated biomechanically because they caused marked elevations in stress on the necrotic cancellous bone. Calculated levels of stress were relatively insensitive to variations in the diameter of the graft.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?