This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haynes, D. R.
Right arrow Articles by Howie, D. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haynes, D. R.
Right arrow Articles by Howie, D. W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 75, Issue 6 825-834, Copyright © 1993 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles

DR Haynes, SD Rogers, S Hay, MJ Pearcy and DW Howie
Department of Orthopaedic Surgery and Trauma, Royal Adelaide Hospital, Australia.

We investigated the relationship between the toxic effects of metal wear particles and their ability to stimulate the release of inflammatory mediators implicated in bone resorption. In vitro studies were carried out with use of rat peritoneal macrophages, which were exposed to either cobalt-chromium-alloy or titanium-aluminum-vanadium particles, milled from the metal components of hip prostheses. The particles were in the size-range of, and at concentrations similar to, those found in the tissues surrounding failed prostheses in humans. The titanium-aluminum-vanadium particles showed little toxicity even at high concentrations, while the cobalt-chromium particles were very toxic. The titanium-aluminum-vanadium particles induced significantly more release of prostaglandin E2 than did the cobalt-chromium particles, and this was true for a wide range of concentrations. Exposure to titanium-aluminum-vanadium increased the release of prostaglandin E2, interleukin-1, tumor necrosis factor, and interleukin-6. In contrast, exposure to cobalt-chromium particles was associated with a decreased release of prostaglandin E2 and interleukin-6, and it had little effect on the release of interleukin-1 and tumor necrosis factor.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
J. Antoniou, D. J. Zukor, F. Mwale, W. Minarik, A. Petit, and O. L. Huk
Metal Ion Levels in the Blood of Patients After Hip Resurfacing: A Comparison Between Twenty-eight and Thirty-six-Millimeter-Head Metal-on-Metal Prostheses
J. Bone Joint Surg. Am., August 1, 2008; 90(Supplement_3): 142 - 148.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
T. W. Bauer and A. S. Shanbhag
Are there biological markers of wear?
J. Am. Acad. Ortho. Surg., July 1, 2008; 16(suppl_1): S68 - S71.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. H. Lohmann, D. D. Dean, L. F. Bonewald, Z. Schwartz, and B. D. Boyan
Nitric Oxide and Prostaglandin E2 Production in Response to Ultra-High Molecular Weight Polyethylene Particles Depends on Osteoblast Maturation State
J. Bone Joint Surg. Am., March 1, 2002; 84(3): 411 - 419.
[Abstract] [Full Text]


Home page
JBJSHome page
N. Maffulli and C. R. Clark
Correspondence
J. Bone Joint Surg. Am., June 1, 1998; 80(6): 923 - 923.
[Full Text]


Home page
JBJSHome page
T. A. BLAINE, P. F. POLLICE, R. N. ROSIER, P. R. REYNOLDS, J. E. PUZAS, and R. J. O'KEEFE
Modulation of the Production of Cytokines in Titanium-Stimulated Human Peripheral Blood Monocytes by Pharmacological Agents. The Role of cAMP-Mediated Signaling Mechanisms*{{dagger}}
J. Bone Joint Surg. Am., October 1, 1997; 79(10): 1519 - 28.
[Abstract] [Full Text]


Home page
JBJSHome page
J. YAO, G. CS-SZABÓ, J. J. JACOBS, K. E. KUETTNER, and T. T. GLANT
Suppression of Osteoblast Function by Titanium Particles*{{dagger}}
J. Bone Joint Surg. Am., January 1, 1997; 79(1): 107 - 12.
[Abstract] [Full Text]


Home page
JBJSHome page
T. A. BLAINE, R. N. ROSIER, J. E. PUZAS, R. J. LOONEY, P. R. REYNOLDS, S. D. REYNOLDS, and R. J. O'KEEFE
Increased Levels of Tumor Necrosis Factor-{{alpha}} and Interleukin-6 Protein and Messenger RNA in Human Peripheral Blood Monocytes due to Titanium Particles
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1181 - 92.
[Abstract] [Full Text]


Home page
JBJSHome page
B. D. MULLIKEN, R. B. BOURNE, C. H. RORABECK, and N. NAYAK
A Tapered Titanium Femoral Stem Inserted without Cement in a Total Hip Arthroplasty. Radiographic Evaluation and Stability
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1214 - 25.
[Abstract] [Full Text]


Home page
JBJSHome page
K. HIRAKAWA, T. W. BAUER, B. N. STULBERG, A. H. WILDE, and M. SECIC
Characterization and Comparison of Wear Debris from Failed Total Hip Implants of Different Types
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1235 - 43.
[Abstract] [Full Text]


Home page
JBJSHome page
M. J. COUGHLIN
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Hallux Valgus*{{dagger}}
J. Bone Joint Surg. Am., June 1, 1996; 78(6): 932 - 66.
[Full Text]


Home page
JBJSHome page
D. G. HICKS, A. R. JUDKINS, J. Z. SICKEL, R. N. ROSIER, J. E. PUZAS, and R. J. O'KEEFE
Granular Histiocytosis of Pelvic Lymph Nodes following Total Hip Arthroplasty. The Presence of Wear Debris, Cytokine Production, and Immunologically Activated Macrophages
J. Bone Joint Surg. Am., April 1, 1996; 78(4): 482 - 96.
[Abstract] [Full Text]