This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martell, J. M.
Right arrow Articles by Galante, J. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martell, J. M.
Right arrow Articles by Galante, J. O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 75, Issue 4 554-571, Copyright © 1993 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement

JM Martell, RH Pierson, JJ Jacobs, AG Rosenberg, M Maley and JO Galante
Department of Orthopaedic Surgery, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois 60612.

A prospective study was done of the intermediate-term clinical and radiographic results of 121 total hip arthroplasties in which a Harris-Galante porous titanium-fiber-coated prosthesis was inserted without cement in 110 patients. The average age at the time of the operation was forty-nine years (range, twenty to seventy years). The average duration of follow-up was sixty-seven months (range, fifty-five to seventy-nine months). The average preoperative Harris hip score was 55 points, and the average postoperative score was 93 points. One acetabular component was revised due to recurrent dislocation. Eleven femoral implants were unstable, and of these, four were revised. Cortical erosion was present around the distal part of the femoral stem in nine patients (8 per cent) who had stable implants, and one of these femoral implants was revised because the erosion was extensive. Survivorship analysis at five years revealed a 97 per cent chance of survival (95 per cent confidence limit, 0.937 to 1.0) of the Harris-Galante femoral-stem implant inserted without cement.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
C. J. D. Valle, T. Shuaipaj, R. A. Berger, A. G. Rosenberg, S. Shott, J. J. Jacobs, and J. O. Galante
Revision of the Acetabular Component without Cement After Total Hip Arthroplasty. A Concise Follow-up, at Fifteen to Nineteen Years, of a Previous Report
J. Bone Joint Surg. Am., August 1, 2005; 87(8): 1795 - 1800.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. J. D. Valle, R. A. Berger, S. Shott, A. G. Rosenberg, J. J. Jacobs, L. Quigley, and J. O. Galante
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. A Concise Follow-up of a Previous Report
J. Bone Joint Surg. Am., June 1, 2004; 86(6): 1217 - 1222.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
R. K. Sinha, D. S. Dungy, and H. B. Yeon
Primary Total Hip Arthroplasty with a Proximally Porous-Coated Femoral Stem
J. Bone Joint Surg. Am., June 1, 2004; 86(6): 1254 - 1261.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. E. Beaule, E. Ebramzadeh, M. LeDuff, R. Prasad, and H. C. Amstutz
Cementing a Liner into a Stable Cementless Acetabular Shell: The Double-Socket Technique
J. Bone Joint Surg. Am., May 1, 2004; 86(5): 929 - 934.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. E. Beaule, M. J. LeDuff, F. J. Dorey, and H. C. Amstutz
Fate of Cementless Acetabular Components Retained During Revision Total Hip Arthroplasty
J. Bone Joint Surg. Am., December 1, 2003; 85(12): 2288 - 2293.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. A. Teloken, G. Bissett, W. J. Hozack, P. F. Sharkey, and R. H. Rothman
Ten to Fifteen-Year Follow-up After Total Hip Arthroplasty with a Tapered Cobalt-Chromium Femoral Component (Tri-Lock) Inserted without Cement
J. Bone Joint Surg. Am., December 9, 2002; 84(12): 2140 - 2144.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
T. H. Mallory, A. V. Lombardi Jr., J. R. Leith, H. Fujita, J. F. Hartman, S. G. Capps, C. A. Kefauver, J. B. Adams, and G. C. Vorys
Why a Taper?
J. Bone Joint Surg. Am., November 25, 2002; 84(90002): S81 - 89.
[Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
T. E. Brown, B. Larson, F. Shen, and J. T. Moskal
Thigh Pain After Cementless Total Hip Arthroplasty: Evaluation and Management
J. Am. Acad. Ortho. Surg., November 1, 2002; 10(6): 385 - 392.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. T. Moskal, F. H. Shen, and T. E. Brown
The Fate of Stable Femoral Components Retained During Isolated Acetabular Revision : A Six-to-Twelve-Year Follow-up Study
J. Bone Joint Surg. Am., February 1, 2002; 84(2): 250 - 255.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. J. Archibeck, R. A. Berger, J. J. Jacobs, L. R. Quigley, S. Gitelis, A. G. Rosenberg, and J. O. Galante
Second-Generation Cementless Total Hip Arthroplasty : Eight to Eleven-Year Results
J. Bone Joint Surg. Am., November 1, 2001; 83(11): 1666 - 1673.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. L. Whaley, D. J. Berry, and W. S. Harmsen
Extra-Large Uncemented Hemispherical Acetabular Components for Revision Total Hip Arthroplasty
J. Bone Joint Surg. Am., September 1, 2001; 83(9): 1352 - 1357.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. F. Pollice, R. N. Rosier, R. J. Looney, J. E. Puzas, E. M. Schwarz, and R. J. O'Keefe
Oral Pentoxifylline Inhibits Release of Tumor Necrosis Factor-Alpha from Human Peripheral Blood Monocytes : A Potential Treatment for Aseptic Loosening of Total Joint Components
J. Bone Joint Surg. Am., July 1, 2001; 83(7): 1057 - 1061.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. Bellabarba, R. A. Berger, C. D. Bentley, L. R. Quigley, J. J. Jacobs, A. G. Rosenberg, M. B. Sheinkop, and J. O. Galante
Cementless Acetabular Reconstruction After Acetabular Fracture
J. Bone Joint Surg. Am., June 1, 2001; 83(6): 868 - 876.
[Abstract] [Full Text]


Home page
JBJSHome page
A. G. DellaValle, P. S. Ruzo, S. Li, P. Pellicci, T. P. Sculco, and E. A. Salvati
Dislodgment of Polyethylene Liners in First and Second-Generatio{-}n Harris-Galante Acetabular Components : A Report of Eighteen Cases
J. Bone Joint Surg. Am., April 1, 2001; 83(4): 553 - 553.
[Abstract] [Full Text]


Home page
JBJSHome page
V. P. Cannestra, R. A. Berger, L. R. Quigley, J. J. Jacobs, A. G. Rosenberg, and J. O. Galante
Hybrid Total Hip Arthroplasty with a Precoated Offset Stem : Four to Nine-Year Results
J. Bone Joint Surg. Am., September 1, 2000; 82(9): 1291 - 1291.
[Abstract] [Full Text]


Home page
JBJSHome page
R. A. BERGER, L. R. QUIGLEY, J. J. JACOBS, M. B. SHEINKOP, A. G. ROSENBERG, and J. O. GALANTE
The Fate of Stable Cemented Acetabular Components Retained During Revision of a Femoral Component of a Total Hip Arthroplasty
J. Bone Joint Surg. Am., December 1, 1999; 81(12): 1682 - 91.
[Abstract] [Full Text]


Home page
JBJSHome page
S. S. LEOPOLD, R. A. BERGER, A. G. ROSENBERG, J. J. JACOBS, L. R. QUIGLEY, and J. O. GALANTE
Impaction Allografting with Cement for Revision of the Femoral Component. A Minimum Four-Year Follow-up Study with Use of a Precoated Femoral Stem
J. Bone Joint Surg. Am., August 1, 1999; 81(8): 1080 - 92.
[Abstract] [Full Text]


Home page
JBJSHome page
J. P. McAULEY, K. D. MOORE, W. J. CULPEPPER, and C. A. ENGH
Total Hip Arthroplasty with Porous-Coated Prostheses Fixed without Cement in Patients Who Are Sixty-five Years of Age or Older
J. Bone Joint Surg. Am., November 1, 1998; 80(11): 1648 - 55.
[Abstract] [Full Text]


Home page
JBJSHome page
M. T. MANLEY, W. N. CAPELLO, J. A. D'ANTONIO, A. A. EDIDIN, and R. G. T. GEESINK
Fixation of Acetabular Cups without Cement in Total Hip Arthroplasty. A Comparison of Three Different Implant Surfaces at a Minimum Duration of Follow-up of Five Years
J. Bone Joint Surg. Am., August 1, 1998; 80(8): 1175 - 85.
[Abstract] [Full Text]


Home page
JBJSHome page
C. F. BURT, K. L. GARVIN, E. T. OTTERBERG, and O. M. JARDON
A Femoral Component Inserted without Cement in Total Hip Arthroplasty. A Study of the Tri-Lock Component with an Average Ten-Year Duration of Follow-up
J. Bone Joint Surg. Am., July 1, 1998; 80(7): 952 - 60.
[Abstract] [Full Text]


Home page
JBJSHome page
J. M. MARTELL and S. BERDIA
Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs
J. Bone Joint Surg. Am., November 1, 1997; 79(11): 1635 - 41.
[Abstract] [Full Text]


Home page
JBJSHome page
R. T. TROUSDALE, D. J. BERRY, J. JACOBS, and J. L. GILBERT
Fracture of an Acetabular Component Inserted without Cement: A Case Report
J. Bone Joint Surg. Am., June 1, 1997; 79(6): 901 - 5.
[Full Text]


Home page
JBJSHome page
G. S. TOMPKINS, J. J. JACOBS, L. R. KULL, A. G. ROSENBERG, and J. O. GALANTE
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. Seven-to-Ten-Year Results
J. Bone Joint Surg. Am., February 1, 1997; 79(2): 169 - 76.
[Abstract] [Full Text]


Home page
JBJSHome page
T. A. BLAINE, R. N. ROSIER, J. E. PUZAS, R. J. LOONEY, P. R. REYNOLDS, S. D. REYNOLDS, and R. J. O'KEEFE
Increased Levels of Tumor Necrosis Factor-{{alpha}} and Interleukin-6 Protein and Messenger RNA in Human Peripheral Blood Monocytes due to Titanium Particles
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1181 - 92.
[Abstract] [Full Text]


Home page
JBJSHome page
B. D. MULLIKEN, R. B. BOURNE, C. H. RORABECK, and N. NAYAK
A Tapered Titanium Femoral Stem Inserted without Cement in a Total Hip Arthroplasty. Radiographic Evaluation and Stability
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1214 - 25.
[Abstract] [Full Text]


Home page
JBJSHome page
R. M. URBAN, J. J. JACOBS, D. R. SUMNER, C. L. PETERS, F. R. VOSS, and J. O. GALANTE
The Bone-Implant Interface of Femoral Stems with Non-Circumferential Porous Coating. A Study of Specimens Retrieved at Autopsy
J. Bone Joint Surg. Am., July 1, 1996; 78(7): 1068 - 81.
[Abstract] [Full Text]


Home page
JBJSHome page
D. J. ASTION, P. SALUAN, B. N. STULBERG, C. M. RIMNAC, and S. LI
The Porous-Coated Anatomic Total Hip Prosthesis: Failure of the Metal-Backed Acetabular Component
J. Bone Joint Surg. Am., May 1, 1996; 78(5): 755 - 66.
[Abstract] [Full Text]