This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moed, B. R.
Right arrow Articles by Thorderson, P. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moed, B. R.
Right arrow Articles by Thorderson, P. K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 75, Issue 2 231-235, Copyright © 1993 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Measurement of intracompartmental pressure: a comparison of the slit catheter, side-ported needle, and simple needle

BR Moed and PK Thorderson
Department of Orthopaedic Surgery, Henry Ford Hospital, Detroit, Michigan 48202-2689.

An experimental model of acute compartment syndrome involving the anterolateral compartment of the hindlimb in dogs was used to compare three methods of measurement of intracompartmental pressure: the simple-needle technique, use of the slit catheter, and use of the side-ported needle. No statistical difference was found between the values obtained with the slit catheter and those obtained with the side-ported needle; the mean difference was 1.4 millimeters of mercury throughout the range of compartment pressures that were measured. The side-ported needle appeared to be as accurate as the slit catheter for the measurement of compartment pressures (p = 0.355, 1-beta = 0.9). The values obtained with use of the simple needle were consistently higher than those obtained with the other two methods (p < 0.001): an average of 18.3 millimeters of mercury higher than the values measured with the slit catheter and 19.3 millimeters of mercury higher than those measured with the side-ported needle. Clinically, the side-ported needle or the slit catheter can be used to obtain accurate measurements of compartment pressure. Use of the simple 18-gauge needle is not recommended for this purpose.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Emerg. Med. J.Home page
J. J Gillooly, A. Hacker, and V. Patel
Compartment syndrome as a complication of a stab wound to the thigh: a case report and review of the literature
Emerg. Med. J., November 1, 2007; 24(11): 780 - 781.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
S. A. Olson and R. R. Glasgow
Acute Compartment Syndrome in Lower Extremity Musculoskeletal Trauma
J. Am. Acad. Ortho. Surg., November 1, 2005; 13(7): 436 - 444.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. R. Boody and M. D. Wongworawat
Accuracy in the Measurement of Compartment Pressures: A Comparison of Three Commonly Used Devices
J. Bone Joint Surg. Am., November 1, 2005; 87(11): 2415 - 2422.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
J. G. H. van den Brand, T. Nelson, E. J. M. M. Verleisdonk, and C. van der Werken
The Diagnostic Value of Intracompartmental Pressure Measurement, Magnetic Resonance Imaging, and Near-Infrared Spectroscopy in Chronic Exertional Compartment Syndrome: A Prospective Study in 50 Patients
Am. J. Sports Med., May 1, 2005; 33(5): 699 - 704.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
J. G. H. van den Brand, E. J. M. M. Verleisdonk, and C. van der Werken
Near Infrared Spectroscopy in the Diagnosis of Chronic Exertional Compartment Syndrome
Am. J. Sports Med., March 1, 2004; 32(2): 452 - 456.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. WILLY, H. GERNGROSS, and J. STERK
Measurement of Intracompartmental Pressure with Use of a New Electronic Transducer-Tipped Catheter System
J. Bone Joint Surg. Am., February 1, 1999; 81(2): 158 - 68.
[Abstract] [Full Text]


Home page
Am J Sports MedHome page
M. K. Gilbart, D. J. Oglivie-Harris, C. Broadhurst, and M. Clarfield
Anterior Tibial Compartment Pressures During Intermittent Sequential Pneumatic Compression Therapy
Am. J. Sports Med., December 1, 1995; 23(6): 769 - 772.
[Abstract] [PDF]