This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow A correction has been published
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heekin, R. D.
Right arrow Articles by Xenos, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heekin, R. D.
Right arrow Articles by Xenos, J. S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 75, Issue 1 77-91, Copyright © 1993 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The porous-coated anatomic total hip prosthesis, inserted without cement. Results after five to seven years in a prospective study

RD Heekin, JJ Callaghan, WJ Hopkinson, CG Savory and JS Xenos
Orthopaedic Service, Walter Reed Army Medical Center, Washington, D.C. 20307-5001.

The results of 100 primary arthroplasties with a porous-coated anatomic total hip prosthesis that were performed consecutively in ninety-one patients were followed prospectively for five to seven years after the operation or until death. Clinical Harris hip ratings and anteroposterior and lateral radiographs were made preoperatively, several times in the first postoperative year, and at annual intervals thereafter. Average sequential hip ratings were maintained between 92 and 93 points during the follow-up interval. Pain in the thigh, which did not limit function, was recorded at the yearly examinations from the first to the fifth year. After one year, 18 per cent of the thighs were painful, and in succeeding years, 19 per cent, 23 per cent, 26 per cent, and 15 per cent were painful. Radiographs demonstrated that the fixation of the femoral component was by ingrowth of bone in 94 per cent of the hips, by stable fibrous fixation in 1 per cent, and by unstable fibrous fixation in 5 per cent, according to the criteria of Engh et al. By five years, 6 per cent of the acetabular components had migrated, and 5 per cent of the femoral components had subsided. Two acetabular components had been revised, and one revision of a femoral component was pending. The evaluated device was an early-generation prosthesis that was designed for insertion without the use of cement. Further study is necessary to determine the long-term durability of the prosthesis-bone interface.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
S. Akhavan, M. M. Matthiesen, L. Schulte, T. Penoyar, M. J. Kraay, C. M. Rimnac, and V. M. Goldberg
Clinical and Histologic Results Related to a Low-Modulus Composite Total Hip Replacement Stem
J. Bone Joint Surg. Am., June 1, 2006; 88(6): 1308 - 1314.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. A. Bojescul, J. S. Xenos, J. J. Callaghan, and C. G. Savory
Results of Porous-Coated Anatomic Total Hip Arthroplasty without Cement at Fifteen Years: A Concise Follow-up of a Previous Report
J. Bone Joint Surg. Am., May 28, 2003; 85(6): 1079 - 1083.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
Y.-H. Kim, S.-H. Oh, and J.-S Kim
Primary Total Hip Arthroplasty with a Second-Generation Cementless Total Hip Prosthesis in Patients Younger Than Fifty Years of Age
J. Bone Joint Surg. Am., January 17, 2003; 85(1): 109 - 114.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. A. Teloken, G. Bissett, W. J. Hozack, P. F. Sharkey, and R. H. Rothman
Ten to Fifteen-Year Follow-up After Total Hip Arthroplasty with a Tapered Cobalt-Chromium Femoral Component (Tri-Lock) Inserted without Cement
J. Bone Joint Surg. Am., December 9, 2002; 84(12): 2140 - 2144.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
T. H. Mallory, A. V. Lombardi Jr., J. R. Leith, H. Fujita, J. F. Hartman, S. G. Capps, C. A. Kefauver, J. B. Adams, and G. C. Vorys
Why a Taper?
J. Bone Joint Surg. Am., November 25, 2002; 84(90002): S81 - 89.
[Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
R. Illgen II and H. E. Rubash
The Optimal Fixation of the Cementless Acetabular Component in Primary Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2002; 10(1): 43 - 56.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
Y. S. Kim, J. J. Callaghan, S. Y. Kwon, K. W. Kim, C. H. Han, and Y. K. Woo
Arthroplasty of the Hip in Patients with Aplastic Anemia
J. Bone Joint Surg. Am., September 1, 2000; 82(9): 1231 - 1231.
[Abstract] [Full Text]


Home page
JBJSHome page
M. J. CHRISTIE, D. K. DEBOER, L. W. TRICK, J. C. BROTHERS, R. E. JONES, G. T. VISE, and T. A. GRUEN
Primary Total Hip Arthroplasty with Use of the Modular S-ROM Prosthesis. Four to Seven-Year Clinical and Radiographic Results
J. Bone Joint Surg. Am., December 1, 1999; 81(12): 1707 - 16.
[Abstract] [Full Text]


Home page
JBJSHome page
A. A. RAGAB, M. J. KRAAY, and V. M. GOLDBERG
Clinical and Radiographic Outcomes of Total Hip Arthroplasty with Insertion of an Anatomically Designed Femoral Component without Cement for the Treatment of Primary Osteoarthritis. A Study with a Minimum of Six Years of Follow-up
J. Bone Joint Surg. Am., February 1, 1999; 81(2): 210 - 8.
[Abstract] [Full Text]


Home page
JBJSHome page
J. C. CLOHISY and W. H. HARRIS
The Harris-Galante Porous-Coated Acetabular Component with Screw Fixation. An Average Ten-Year Follow-up Study
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 66 - 73.
[Abstract] [Full Text]


Home page
JBJSHome page
J. S. XENOS, J. J. CALLAGHAN, R. D. HEEKIN, W. J. HOPKINSON, C. G. SAVORY, and M. S. MOORE
The Porous-Coated Anatomic Total Hip Prosthesis, Inserted without Cement. A Prospective Study with a Minimum Ten Years of Follow-up
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 74 - 82.
[Abstract] [Full Text]


Home page
JBJSHome page
M. T. MANLEY, W. N. CAPELLO, J. A. D'ANTONIO, A. A. EDIDIN, and R. G. T. GEESINK
Fixation of Acetabular Cups without Cement in Total Hip Arthroplasty. A Comparison of Three Different Implant Surfaces at a Minimum Duration of Follow-up of Five Years
J. Bone Joint Surg. Am., August 1, 1998; 80(8): 1175 - 85.
[Abstract] [Full Text]


Home page
JBJSHome page
C. F. BURT, K. L. GARVIN, E. T. OTTERBERG, and O. M. JARDON
A Femoral Component Inserted without Cement in Total Hip Arthroplasty. A Study of the Tri-Lock Component with an Average Ten-Year Duration of Follow-up
J. Bone Joint Surg. Am., July 1, 1998; 80(7): 952 - 60.
[Abstract] [Full Text]


Home page
JBJSHome page
W. N. CAPELLO, J. A. D'ANTONIO, J. R. FEINBERG, and M. T. MANLEY
Hydroxyapatite-Coated Total Hip Femoral Components in Patients Less Than Fifty Years Old. Clinical and Radiographic Results after Five to Eight Years of Follow-up
J. Bone Joint Surg. Am., July 1, 1997; 79(7): 1023 - 9.
[Abstract] [Full Text]


Home page
JBJSHome page
C. A. ENGH JR., W. J. CULPEPPER II, and C. A. ENGH
Long-Term Results of Use of the Anatomic Medullary Locking Prosthesis in Total Hip Arthroplasty
J. Bone Joint Surg. Am., February 1, 1997; 79(2): 177 - 84.
[Abstract] [Full Text]


Home page
JBJSHome page
B. D. MULLIKEN, R. B. BOURNE, C. H. RORABECK, and N. NAYAK
A Tapered Titanium Femoral Stem Inserted without Cement in a Total Hip Arthroplasty. Radiographic Evaluation and Stability
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1214 - 25.
[Abstract] [Full Text]


Home page
JBJSHome page
J. A. D'ANTONIO, W. N. CAPELLO, and M. T. MANLEY
Remodeling of Bone around Hydroxyapatite-Coated Femoral Stems
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1226 - 34.
[Abstract] [Full Text]


Home page
JBJSHome page
H. A. LATIMER and P. F. LACHIEWICZ
Porous-Coated Acetabular Components with Screw Fixation. Five to Ten-Year Results
J. Bone Joint Surg. Am., July 1, 1996; 78(7): 975 - 81.
[Abstract] [Full Text]


Home page
JBJSHome page
R. M. URBAN, J. J. JACOBS, D. R. SUMNER, C. L. PETERS, F. R. VOSS, and J. O. GALANTE
The Bone-Implant Interface of Femoral Stems with Non-Circumferential Porous Coating. A Study of Specimens Retrieved at Autopsy
J. Bone Joint Surg. Am., July 1, 1996; 78(7): 1068 - 81.
[Abstract] [Full Text]