This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmalzried, T. P.
Right arrow Articles by Harris, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmalzried, T. P.
Right arrow Articles by Harris, W. H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 74, Issue 8 1130-1139, Copyright © 1992 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years

TP Schmalzried and WH Harris
Orthopaedic Biomechanics Laboratory, Massachusetts General Hospital, Boston 02114.

The results of eighty-three consecutive primary total hip arthroplasties in which a Harris-Galante porous-coated acetabular component had been used were reviewed after a minimum of five years. In all patients, the stated diameter of the acetabular component (the diameter printed on the packaging for the implant) used was equal to the stated diameter of the reamer (the diameter printed on the reamer) that had been used last in the preparation of the acetabulum. As there was little or no press-fit stability, stability was obtained initially with multiple transfixing screws. No component was revised because of loosening, and none were radiographically loose at an average of sixty-eight months and a maximum of seven years after the operation. There was no evidence of disruption of the titanium porous mesh, and no screw had bent or broken. Two sockets, however, had been revised because of failure of the liner-locking mechanism as well as disassociation of the polyethylene liner from the titanium-alloy shell. Lysis of bone occurred in only one patient, around one screw. Areas of non-contact (gaps) between the porous mesh at the periphery of the acetabular component and the bone were seen on the immediate postoperative radiographs of nearly half of the patients. New areas of radiolucency, which had not been seen immediately postoperatively, were identified at two years in forty-nine hips. These radiolucent lines were never wider than one millimeter and were most frequently located in zone 3 and, less frequently, in zone 1. At the time of the most recent follow-up evaluation, a progressive radiolucent line was identified around twenty-two components and a discontinuous radiolucent line was present in all three zones around eleven components. No continuous radiolucent line was identified at the mesh-bone interface of any component. These results are superior to our results with cemented acetabular components after a similar period of follow-up. A longer period of follow-up is needed before the importance of these thin radiolucent lines can be determined, but experience with cemented acetabular components indicates that progressive or extensive radiolucent lines, or both, may represent resorption of bone at the porous mesh-bone interface and this can lead to loosening of the component. Our data suggest that the technique used for implantation may be important not only for the initial fixation and ingrowth of bone, but also for the long-term durability of the fixation of a porous-coated acetabular component.(ABSTRACT TRUNCATED AT 400 WORDS)
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
K. J. Hendricks and W. H. Harris
High Placement of Noncemented Acetabular Components in Revision Total Hip Arthroplasty. A Concise Follow-Up, at a Minimum of Fifteen Years, of a Previous Report
J. Bone Joint Surg. Am., October 1, 2006; 88(10): 2231 - 2236.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
G. J. Haidukewych, D. J. Jacofsky, A. D. Hanssen, and D. G. Lewallen
Intraoperative Fractures of the Acetabulum During Primary Total Hip Arthroplasty
J. Bone Joint Surg. Am., September 1, 2006; 88(9): 1952 - 1956.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
G. A. Macheras, P. J. Papagelopoulos, K. Kateros, A. T. Kostakos, D. Baltas, and T. S. Karachalios
Radiological evaluation of the metal-bone interface of a porous tantalum monoblock acetabular component
J Bone Joint Surg Br, March 1, 2006; 88-B(3): 304 - 309.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. T. Moskal, F. H. Shen, and T. E. Brown
The Fate of Stable Femoral Components Retained During Isolated Acetabular Revision : A Six-to-Twelve-Year Follow-up Study
J. Bone Joint Surg. Am., February 1, 2002; 84(2): 250 - 255.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
R. Illgen II and H. E. Rubash
The Optimal Fixation of the Cementless Acetabular Component in Primary Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2002; 10(1): 43 - 56.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. Udomkiat, Z. Wan, and L. D. Dorr
Comparison of Preoperative Radiographs and Intraoperative Findings of Fixation of Hemispheric Porous-Coated Sockets
J. Bone Joint Surg. Am., December 1, 2001; 83(12): 1865 - 1870.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. M. Wright, P. M. Pellicci, E. A. Salvati, B. Ghelman, M. M. Roberts, and J. L. Koh
Bone Density Adjacent to Press-Fit Acetabular Components : A Prospective Analysis with Quantitative Computed Tomography
J. Bone Joint Surg. Am., April 1, 2001; 83(4): 529 - 529.
[Abstract] [Full Text]


Home page
JBJSHome page
A. G. DellaValle, P. S. Ruzo, S. Li, P. Pellicci, T. P. Sculco, and E. A. Salvati
Dislodgment of Polyethylene Liners in First and Second-Generatio{-}n Harris-Galante Acetabular Components : A Report of Eighteen Cases
J. Bone Joint Surg. Am., April 1, 2001; 83(4): 553 - 553.
[Abstract] [Full Text]


Home page
JBJSHome page
Y. S. Kim, J. J. Callaghan, S. Y. Kwon, K. W. Kim, C. H. Han, and Y. K. Woo
Arthroplasty of the Hip in Patients with Aplastic Anemia
J. Bone Joint Surg. Am., September 1, 2000; 82(9): 1231 - 1231.
[Abstract] [Full Text]


Home page
JBJSHome page
J. T. Dearborn and W. H. Harris
Acetabular Revision After Failed Total Hip Arthroplasty in Patients with Congenital Hip Dislocation and Dysplasia : Results After a Mean of 8.6 Years
J. Bone Joint Surg. Am., August 1, 2000; 82(8): 1146 - 1146.
[Abstract] [Full Text]


Home page
JBJSHome page
R. A. BERGER, L. R. QUIGLEY, J. J. JACOBS, M. B. SHEINKOP, A. G. ROSENBERG, and J. O. GALANTE
The Fate of Stable Cemented Acetabular Components Retained During Revision of a Femoral Component of a Total Hip Arthroplasty
J. Bone Joint Surg. Am., December 1, 1999; 81(12): 1682 - 91.
[Abstract] [Full Text]


Home page
JBJSHome page
F. S. HADDAD, B. A. MASRI, D. S. GARBUZ, and C. P. DUNCAN
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Primary Total Replacement of the Dysplastic Hip*{{dagger}}
J. Bone Joint Surg. Am., October 1, 1999; 81(10): 1462 - 82.
[Full Text]


Home page
JBJSHome page
J. T. DEARBORN and W. H. HARRIS
High Placement of an Acetabular Component Inserted without Cement in a Revision Total Hip Arthroplasty. Results After a Mean of Ten Years
J. Bone Joint Surg. Am., April 1, 1999; 81(4): 469 - 80.
[Abstract] [Full Text]


Home page
JBJSHome page
S. M. SPORER, J. J. CALLAGHAN, J. P. OLEJNICZAK, D. D. GOETZ, and R. C. JOHNSTON
The Effects of Surface Roughness and Polymethylmethacrylate Precoating on the Radiographic and Clinical Results of the Iowa Hip Prosthesis. A Study of Patients Less Than Fifty Years Old
J. Bone Joint Surg. Am., April 1, 1999; 81(4): 481 - 92.
[Abstract] [Full Text]


Home page
JBJSHome page
M. J. ANDERSON and W. H. HARRIS
Total Hip Arthroplasty with Insertion of the Acetabular Component without Cement in Hips with Total Congenital Dislocation or Marked Congenital Dysplasia
J. Bone Joint Surg. Am., March 1, 1999; 81(3): 347 - 54.
[Abstract] [Full Text]


Home page
JBJSHome page
M. B. PETERSEN, I. H. POULSEN, J. THOMSEN, and S. SOLGAARD
The Hemispherical Harris-Galante Acetabular Cup, Inserted without Cement. The Results of an Eight to Eleven-Year Follow-up of One Hundred and Sixty-Eight Hips
J. Bone Joint Surg. Am., February 1, 1999; 81(2): 219 - 24.
[Abstract] [Full Text]


Home page
JBJSHome page
J. C. CLOHISY and W. H. HARRIS
Primary Hybrid Total Hip Replacement, Performed with Insertion of the Acetabular Component without Cement and a Precoat Femoral Component with Cement. An Average Ten-Year Follow-up Study
J. Bone Joint Surg. Am., February 1, 1999; 81(2): 247 - 55.
[Abstract] [Full Text]


Home page
JBJSHome page
J. C. CLOHISY and W. H. HARRIS
The Harris-Galante Porous-Coated Acetabular Component with Screw Fixation. An Average Ten-Year Follow-up Study
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 66 - 73.
[Abstract] [Full Text]


Home page
JBJSHome page
T. P. SCHMALZRIED and J. J. CALLAGHAN
Current Concepts Review - Wear in Total Hip and Knee Replacements
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 115 - 136.
[Full Text]


Home page
JBJSHome page
M. T. MANLEY, W. N. CAPELLO, J. A. D'ANTONIO, A. A. EDIDIN, and R. G. T. GEESINK
Fixation of Acetabular Cups without Cement in Total Hip Arthroplasty. A Comparison of Three Different Implant Surfaces at a Minimum Duration of Follow-up of Five Years
J. Bone Joint Surg. Am., August 1, 1998; 80(8): 1175 - 85.
[Abstract] [Full Text]


Home page
JBJSHome page
M. L. Ecker, H. A. Latimer, and P. F. Lachiewicz
Correspondence
J. Bone Joint Surg. Am., December 1, 1997; 79(12): 1891-a - 1891.
[Full Text]


Home page
JBJSHome page
J. J. CALLAGHAN
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Periprosthetic Fractures of the Acetabulum during and following Total Hip Arthroplasty*{{dagger}}
J. Bone Joint Surg. Am., September 1, 1997; 79(9): 1416 - 21.
[Full Text]


Home page
JBJSHome page
R. T. TROUSDALE, D. J. BERRY, J. JACOBS, and J. L. GILBERT
Fracture of an Acetabular Component Inserted without Cement: A Case Report
J. Bone Joint Surg. Am., June 1, 1997; 79(6): 901 - 5.
[Full Text]


Home page
JBJSHome page
A. A. SHINAR and W. H. HARRIS
Bulk Structural Autogenous Grafts and Allografts for Reconstruction of the Acetabulum in Total Hip Arthroplasty. Sixteen-Year-Average Follow-up
J. Bone Joint Surg. Am., February 1, 1997; 79(2): 159 - 68.
[Abstract] [Full Text]


Home page
JBJSHome page
G. S. TOMPKINS, J. J. JACOBS, L. R. KULL, A. G. ROSENBERG, and J. O. GALANTE
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. Seven-to-Ten-Year Results
J. Bone Joint Surg. Am., February 1, 1997; 79(2): 169 - 76.
[Abstract] [Full Text]


Home page
JBJSHome page
L. C. M. P. MULDOON, D. E. PADGETT, L. R. ROTHEN, G. W. CADY, and L. C. A. S. MELILLO
Failure of a Non-Porous-Coated Acetabular Component Inserted without Cement in Primary Total Hip Arthroplasty*{{dagger}}
J. Bone Joint Surg. Am., October 1, 1996; 78(10): 1486 - 90.
[Abstract] [Full Text]


Home page
JBJSHome page
H. A. LATIMER and P. F. LACHIEWICZ
Porous-Coated Acetabular Components with Screw Fixation. Five to Ten-Year Results
J. Bone Joint Surg. Am., July 1, 1996; 78(7): 975 - 81.
[Abstract] [Full Text]


Home page
JBJSHome page
D. J. ASTION, P. SALUAN, B. N. STULBERG, C. M. RIMNAC, and S. LI
The Porous-Coated Anatomic Total Hip Prosthesis: Failure of the Metal-Backed Acetabular Component
J. Bone Joint Surg. Am., May 1, 1996; 78(5): 755 - 66.
[Abstract] [Full Text]