This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sanders, R.
Right arrow Articles by Helfet, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sanders, R.
Right arrow Articles by Helfet, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 73, Issue 3 341-346, Copyright © 1991 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Double-plating of comminuted, unstable fractures of the distal part of the femur

R Sanders, M Swiontkowski, H Rosen and D Helfet
Vanderbilt University Medical Center, Nashville.

The cases of nine patients who had a complex fracture of the distal part of the femur and a deficient medial-cortical buttress were reviewed. Stable fixation was not achieved with the lateral condylar buttress plate alone. Collapse of the distal fragment into varus angulation was noted intraoperatively, with the axis of rotation being the junction of the distal screws and the plate. Additional stabilization with a medial plate and a bone graft from the iliac crest was applied in all nine patients: in six, at the time of the index operation and in the remaining three, after the open wound and open fracture were considered clean. At an average duration of follow-up of twenty-six months (range, twenty-one to thirty-four months), all of the fractures had healed. Evaluation of the functional outcome revealed five good and four fair results. In three patients, less than 90 degrees of flexion of the knee was present and in six, the arc of flexion was limited to between 90 and 100 degrees. Additionally, four patients had an extensor lag of 5 degrees.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
H. A. Vallier, T. A. Hennessey, J. K. Sontich, and B. M. Patterson
Failure of LCP Condylar Plate Fixation in the Distal Part of the Femur. A Report of Six Cases
J. Bone Joint Surg. Am., April 1, 2006; 88(4): 846 - 853.
[Full Text] [PDF]


Home page
JBJSHome page
S. E. Nork, D. N. Segina, K. Aflatoon, D. P. Barei, M. B. Henley, S. Holt, and S. K. Benirschke
The Association Between Supracondylar-Intercondylar Distal Femoral Fractures and Coronal Plane Fractures
J. Bone Joint Surg. Am., March 1, 2005; 87(3): 564 - 569.
[Abstract] [Full Text] [PDF]