This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jacobs, J. J.
Right arrow Articles by Galante, J. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jacobs, J. J.
Right arrow Articles by Galante, J. O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 73, Issue 10 1475-1486, Copyright © 1991 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy

JJ Jacobs, AK Skipor, J Black, Rm Urban and JO Galante
Department of Orthopedic Surgery, Rush-Presbyterian-St. Luke's Medical Center, Chicago, Illinois 60612.

Serum concentration and urinary excretion of titanium, aluminum, and vanadium were measured for patients who had a well functioning cementless primary total hip replacement of one of two different designs, for patients who had a loose total hip replacement that was to be revised, and for control subjects who had no implant. Serum concentrations of titanium were elevated approximately twofold in the patients who had a loose implant, compared with the values for the control subjects. No major differences in terms of urine concentration of titanium, serum concentration of aluminum, or urine concentration of aluminum were observed among any of the groups that were studied. Concentrations of vanadium were uniformly low in all groups.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Journal of the American Dental AssociationHome page
H. S. McGuff, J. Heim-Hall, F. C. Holsinger, A. A. Jones, D. S. O'Dell, and A. C. Hafemeister
Maxillary Osteosarcoma Associated With a Dental Implant: Report of a Case and Review of the Literature Regarding Implant-Related Sarcomas
J Am Dent Assoc, August 1, 2008; 139(8): 1052 - 1059.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
E. Dunstan, A. P. Sanghrajka, S. Tilley, P. Unwin, G. Blunn, S. R. Cannon, and T. W. R. Briggs
Metal ion levels after metal-on-metal proximal femoral replacements: A 30-YEAR FOLLOW-UP
J Bone Joint Surg Br, May 1, 2005; 87-B(5): 628 - 631.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. Heisel, M. Silva, A. K. Skipor, J. J. Jacobs, and T. P. Schmalzried
The Relationship Between Activity and Ions in Patients with Metal-on-Metal Bearing Hip Prostheses
J. Bone Joint Surg. Am., April 1, 2005; 87(4): 781 - 787.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. Campbell, R. M. Urban, I. Catelas, A. K. Skipor, and T. P. Schmalzried
Autopsy Analysis Thirty Years After Metal-on-Metal Total Hip Replacement. A Case Report
J. Bone Joint Surg. Am., November 1, 2003; 85(11): 2218 - 2222.
[Full Text] [PDF]


Home page
JBJSHome page
J. J. JACOBS, A. K. SKIPOR, L. M. PATTERSON, N. J. HALLAB, W. G. PAPROSKY, J. BLACK, and J. O. GALANTE
Metal Release in Patients Who Have Had a Primary Total Hip Arthroplasty. A Prospective, Controlled, Longitudinal Study
J. Bone Joint Surg. Am., October 1, 1998; 80(10): 1447 - 58.
[Abstract] [Full Text]


Home page
JBJSHome page
J. J. JACOBS, J. L. GILBERT, and R. M. URBAN
Current Concepts Review - Corrosion of Metal Orthopaedic Implants
J. Bone Joint Surg. Am., February 1, 1998; 80(2): 268 - 82.
[Full Text]


Home page
JBJSHome page
C. A. ENGH JR., K. D. MOORE, T. N. VINH, and G. A. ENGH
Titanium Prosthetic Wear Debris in Remote Bone Marrow. A Report of Two Cases
J. Bone Joint Surg. Am., November 1, 1997; 79(11): 1721 - 5.
[Full Text]


Home page
JBJSHome page
B. D. MULLIKEN, R. B. BOURNE, C. H. RORABECK, and N. NAYAK
A Tapered Titanium Femoral Stem Inserted without Cement in a Total Hip Arthroplasty. Radiographic Evaluation and Stability
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1214 - 25.
[Abstract] [Full Text]