The Journal of Bone and Joint Surgery, Vol 72, Issue 5 672-677, Copyright © 1990 by Journal of Bone and Joint Surgery, Inc
Metal-backed acetabular cups in total hip arthroplasty
MA Ritter, EM Keating, PM Faris and G Brugo
Center for Hip and Knee Surgery, Mooresville, Indiana.
Metal backing for the acetabular component of a total hip replacement,
initially designed to allow replacement of the polyethylene liner, has
since been universally accepted as a means of decreasing peak stresses at
the interfaces of bone and cement. We studied the results of 238 total hip
replacements that had been performed between 1980 and 1983 and that
differed only in that 138 of the acetabular components had a metal backing
and 100 were made of polyethylene only. Kaplan-Meier survival analysis,
with three different modes of failure (radiolucency, loosening, and
revision), showed a significant increase in the rate of failure of the
metal-backed acetabular cup compared with the all-polyethylene cup:
radiolucency, 39 compared with 23 per cent (p less than 0.0001); loosening,
4 compared with 2 per cent (p less than 0.0001); and revision, 6 compared
with 2 per cent (p less than 0.0034). It was concluded that metal backing
cannot be recommended for a cemented acetabular component of a total
hip-replacement system.

CiteULike Connotea Del.icio.us Technorati What's this?
This article has been cited by other articles:

|
 |

|
 |
 
J. J. Callaghan, S. S. Liu, D. E. Firestone, T. M. Yehyawi, D. D. Goetz, J. Sullivan, D. A. Vittetoe, M. R. O'Rourke, and R. C. Johnston
Total Hip Arthroplasty with Cement and Use of a Collared Matte-Finish Femoral Component. Nineteen to Twenty-Year Follow-up
J. Bone Joint Surg. Am.,
February 1, 2008;
90(2):
299 - 306.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Chougle, M.V. Hemmady, and J.P. Hodgkinson
Long-Term Survival of the Acetabular Component After Total Hip Arthroplasty with Cement in Patients with Developmental Dysplasia of the Hip
J. Bone Joint Surg. Am.,
January 1, 2006;
88(1):
71 - 79.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Illgen II and H. E. Rubash
The Optimal Fixation of the Cementless Acetabular Component in Primary Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg.,
January 1, 2002;
10(1):
43 - 56.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. D. Dorr, Z. Wan, D. B. Longjohn, B. Dubois, and R. Murken
Total Hip Arthroplasty with Use of the Metasul Metal-on-Metal Articulation : Four to Seven-Year Results
J. Bone Joint Surg. Am.,
June 1, 2000;
82(6):
789 - 789.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
B. J. LIVINGSTON, M. J. CHMELL, M. SPECTOR, and R. POSS
Complications of Total Hip Arthroplasty Associated with the Use of an Acetabular Component with a Hylamer Liner
J. Bone Joint Surg. Am.,
October 1, 1997;
79(10):
1529 - 38.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
P. A. DEVANE, E. J. ROBINSON, R. B. BOURNE, C. H. RORABECK, N. N. NAYAK, and J. G. HORNE
Measurement of Polyethylene Wear in Acetabular Components Inserted with and without Cement. A Randomized Trial
J. Bone Joint Surg. Am.,
May 1, 1997;
79(5):
682 - 89.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
G. S. TOMPKINS, J. J. JACOBS, L. R. KULL, A. G. ROSENBERG, and J. O. GALANTE
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. Seven-to-Ten-Year Results
J. Bone Joint Surg. Am.,
February 1, 1997;
79(2):
169 - 76.
[Abstract]
[Full Text]
|
 |
|
|