This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ritter, M. A.
Right arrow Articles by Brugo, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ritter, M. A.
Right arrow Articles by Brugo, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 72, Issue 5 672-677, Copyright © 1990 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Metal-backed acetabular cups in total hip arthroplasty

MA Ritter, EM Keating, PM Faris and G Brugo
Center for Hip and Knee Surgery, Mooresville, Indiana.

Metal backing for the acetabular component of a total hip replacement, initially designed to allow replacement of the polyethylene liner, has since been universally accepted as a means of decreasing peak stresses at the interfaces of bone and cement. We studied the results of 238 total hip replacements that had been performed between 1980 and 1983 and that differed only in that 138 of the acetabular components had a metal backing and 100 were made of polyethylene only. Kaplan-Meier survival analysis, with three different modes of failure (radiolucency, loosening, and revision), showed a significant increase in the rate of failure of the metal-backed acetabular cup compared with the all-polyethylene cup: radiolucency, 39 compared with 23 per cent (p less than 0.0001); loosening, 4 compared with 2 per cent (p less than 0.0001); and revision, 6 compared with 2 per cent (p less than 0.0034). It was concluded that metal backing cannot be recommended for a cemented acetabular component of a total hip-replacement system.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
J. J. Callaghan, S. S. Liu, D. E. Firestone, T. M. Yehyawi, D. D. Goetz, J. Sullivan, D. A. Vittetoe, M. R. O'Rourke, and R. C. Johnston
Total Hip Arthroplasty with Cement and Use of a Collared Matte-Finish Femoral Component. Nineteen to Twenty-Year Follow-up
J. Bone Joint Surg. Am., February 1, 2008; 90(2): 299 - 306.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. Chougle, M.V. Hemmady, and J.P. Hodgkinson
Long-Term Survival of the Acetabular Component After Total Hip Arthroplasty with Cement in Patients with Developmental Dysplasia of the Hip
J. Bone Joint Surg. Am., January 1, 2006; 88(1): 71 - 79.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
R. Illgen II and H. E. Rubash
The Optimal Fixation of the Cementless Acetabular Component in Primary Total Hip Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2002; 10(1): 43 - 56.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
L. D. Dorr, Z. Wan, D. B. Longjohn, B. Dubois, and R. Murken
Total Hip Arthroplasty with Use of the Metasul Metal-on-Metal Articulation : Four to Seven-Year Results
J. Bone Joint Surg. Am., June 1, 2000; 82(6): 789 - 789.
[Abstract] [Full Text]


Home page
JBJSHome page
B. J. LIVINGSTON, M. J. CHMELL, M. SPECTOR, and R. POSS
Complications of Total Hip Arthroplasty Associated with the Use of an Acetabular Component with a Hylamer Liner
J. Bone Joint Surg. Am., October 1, 1997; 79(10): 1529 - 38.
[Abstract] [Full Text]


Home page
JBJSHome page
P. A. DEVANE, E. J. ROBINSON, R. B. BOURNE, C. H. RORABECK, N. N. NAYAK, and J. G. HORNE
Measurement of Polyethylene Wear in Acetabular Components Inserted with and without Cement. A Randomized Trial
J. Bone Joint Surg. Am., May 1, 1997; 79(5): 682 - 89.
[Abstract] [Full Text]


Home page
JBJSHome page
G. S. TOMPKINS, J. J. JACOBS, L. R. KULL, A. G. ROSENBERG, and J. O. GALANTE
Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. Seven-to-Ten-Year Results
J. Bone Joint Surg. Am., February 1, 1997; 79(2): 169 - 76.
[Abstract] [Full Text]