This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Botte, M. J.
Right arrow Articles by Garfin, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Botte, M. J.
Right arrow Articles by Garfin, S. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 69, Issue 5 750-752, Copyright © 1987 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Application of the halo device for immobilization of the cervical spine utilizing an increased torque pressure

MJ Botte, TP Byrne and SR Garfin

The rates for loosening and infection of the pins used in the halo apparatus are unfortunately high. The commonly recommended amount of torque to be used in applying the pins is 0.68 newton-meter (six inch-pounds). Forty-two adult patients underwent application of a halo device for immobilization of the cervical spine using an increased torque of 0.90 newton-meter (eight inch-pounds). The rate for loosening of the pins and the rate for infection at the pin site dropped from 36 per cent to 7 per cent and 20 per cent to 2 per cent, respectively.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
L. A.B. Copley, J. P. Dormans, M. D. Pepe, V. Tan, and R. H. Browne
Accuracy and Reliability of Torque Wrenches Used for Halo Application in Children
J. Bone Joint Surg. Am., November 1, 2003; 85(11): 2199 - 2204.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. A. Nemeth and L. G. Mattingly
Six-Pin Halo Fixation and the Resulting Prevalence of Pin-Site Complications
J. Bone Joint Surg. Am., March 1, 2001; 83(3): 377 - 377.
[Abstract] [Full Text]


Home page
JBJSHome page
M. D. SMITH, L. J. JOHNSON, J. H. PERRA, and B. A. RAWLINS
A Biomechanical Study of Torque and Accuracy of Halo Pin Insertional Devices
J. Bone Joint Surg. Am., February 1, 1996; 78(2): 231 - 8.
[Abstract] [Full Text]