This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bartel, D. L.
Right arrow Articles by Wright, T. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bartel, D. L.
Right arrow Articles by Wright, T. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 68, Issue 7 1041-1051, Copyright © 1986 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement

DL Bartel, VL Bicknell and TM Wright

Debris resulting from damage to the surface of polyethylene components of total joint replacements has previously been shown to contribute to long-term problems such as loosening and infection. Surface damage has been associated with fatigue processes due to stresses arising from contact between the metal and polyethylene components in these prostheses. In the present study, we used elasticity and finite-element solutions to determine these stresses for total hip replacements with head diameters of twenty-two and twenty-eight millimeters and for a condylar total knee replacement. We also examined the effect on these stresses of using carbon-fiber-reinforced polyethylene instead of plain polyethylene. Stresses associated with surface damage in the tibial component of the total knee replacement were much larger than those in the hip replacements. The analysis of contact stress as a function of thickness of the polyethylene insert for tibial components showed that a thickness of more than eight to ten millimeters should be maintained when possible. The contact stress in the tibial components was reduced most when the articulating surfaces were more conforming in the medial-lateral direction. Contact stresses were much less sensitive to changes in geometry in the anterior-posterior direction. For the hip components, the stresses were lower in the acetabular component of the twenty-eight-millimeter hip replacement than in the twenty-two-millimeter replacement. The use of carbon-fiber-reinforced polyethylene resulted in stresses that were higher by as much as 40 per cent. Because the contact area between articulating surfaces moves during flexion, portions of the surface will be subjected to cyclic stresses. The contact area for the knee replacements in flexion was smaller than for the hip replacements, and the range of the maximum principal stress was larger. Consequently, the combination of the higher stress and the moving contact area is more likely to cause surface damage due to fatigue in tibial components than in acetabular components, which is consistent with clinical observations.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J Am Acad Orthop SurgHome page
T. D. Brown and D. L. Bartel
What design factors influence wear behavior at the bearing surfaces in total joint replacements?
J. Am. Acad. Ortho. Surg., July 1, 2008; 16(suppl_1): S101 - S106.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
D. D.R. Naudie, D. J. Ammeen, G. A. Engh, and C. H. Rorabeck
Wear and Osteolysis Around Total Knee Arthroplasty
J. Am. Acad. Ortho. Surg., January 1, 2007; 15(1): 53 - 64.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
J. M. Loughead, I. Starks, D. Chesney, J. N. S. Matthews, A. W. McCaskie, and J. P. Holland
Removal of acetabular bone in resurfacing arthroplasty of the hip: A COMPARISON WITH HYBRID TOTAL HIP ARTHROPLASTY
J Bone Joint Surg Br, January 1, 2006; 88-B(1): 31 - 34.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. P. Little, A. J. Graham, G. Karatzas, D. A. Woods, and A. J. Carr
Outcomes of Total Elbow Arthroplasty for Rheumatoid Arthritis: Comparative Study of Three Implants
J. Bone Joint Surg. Am., November 1, 2005; 87(11): 2439 - 2448.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
J. Arora and A. C. Ogden
Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement
J Bone Joint Surg Br, November 1, 2005; 87-B(11): 1502 - 1506.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
J. J. Callaghan, M. R. O'Rourke, M. F. Iossi, S. S. Liu, D. D. Goetz, D. A. Vittetoe, P. M. Sullivan, and R. C. Johnston
Cemented Rotating-Platform Total Knee Replacement. A Concise Follow-up, at a Minimum of Fifteen Years, of a Previous Report
J. Bone Joint Surg. Am., September 1, 2005; 87(9): 1995 - 1998.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. C. Dixon, R. R. Brown, D. Parsch, and R. D. Scott
Modular Fixed-Bearing Total Knee Arthroplasty with Retention of the Posterior Cruciate Ligament. A Study of Patients Followed for a Minimum of Fifteen Years
J. Bone Joint Surg. Am., March 1, 2005; 87(3): 598 - 603.
[Abstract] [Full Text] [PDF]


Home page
J Am Acad Orthop SurgHome page
M. H. Gonzalez and A. O. Mekhail
The Failed Total Knee Arthroplasty: Evaluation and Etiology
J. Am. Acad. Ortho. Surg., November 1, 2004; 12(6): 436 - 446.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
L. Bradford, D. A. Baker, J. Graham, A. Chawan, M. D. Ries, and L. A. Pruitt
Wear and Surface Cracking in Early Retrieved Highly Cross-linked Polyethylene Acetabular Liners
J. Bone Joint Surg. Am., June 1, 2004; 86(6): 1271 - 1282.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. A. Conditt, J. A. Stein, and P. C. Noble
Factors Affecting the Severity of Backside Wear of Modular Tibial Inserts
J. Bone Joint Surg. Am., February 1, 2004; 86(2): 305 - 311.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
O. K. Muratoglu, A. Mark, D. A. Vittetoe, W. H. Harris, and H. E. Rubash
Polyethylene Damage in Total Knees and Use of Highly Crosslinked Polyethylene
J. Bone Joint Surg. Am., January 21, 2003; 85(90001): S7 - 13.
[Full Text] [PDF]


Home page
JBJSHome page
M. R. O'Rourke, J. J. Callaghan, D. D. Goetz, P. M. Sullivan, and R. C. Johnston
Osteolysis Associated with a Cemented tModular Posterior-Cruciate-Substituting Total Knee Design : Five to Eight-Year Follow-up
J. Bone Joint Surg. Am., August 12, 2002; 84(8): 1362 - 1371.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
S. A. Edwards, H. G. Pandit, J. L. Ramos, and M. L. Grover
Analysis of Polyethylene Thickness of Tibial Components in Total Knee Replacement
J. Bone Joint Surg. Am., March 1, 2002; 84(3): 369 - 371.
[Abstract] [Full Text]


Home page
JBJSHome page
F. DiFazio, W. Y. Shon, E. A. Salvati, and P. D. Wilson Jr.
Long-Term Results of Total Hip Arthroplasty with a Cemented Custom-Designed Swan-Neck Femoral Component for Congenital Dislocation or Severe Dysplasia : A Follow-up Note
J. Bone Joint Surg. Am., February 1, 2002; 84(2): 204 - 207.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. M. Young, C. J. Sychterz, R. H. Hopper Jr., and C. A. Engh
Effect of Acetabular Modularity on Polyethylene Wear and Osteolysis in Total Hip Arthroplasty
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 58 - 63.
[Abstract] [Full Text]


Home page
JBJSHome page
G. C. Babis, R. T. Trousdale, and B. F. Morrey
The Effectiveness of Isolated Tibial Insert Exchange in Revision Total Knee Arthroplasty
J. Bone Joint Surg. Am., January 1, 2002; 84(1): 64 - 68.
[Abstract] [Full Text]


Home page
J Am Acad Orthop SurgHome page
C. J. Vertullo, M. E. Easley, W. N. Scott, and J. N. Insall
Mobile Bearings in Primary Knee Arthroplasty
J. Am. Acad. Ortho. Surg., November 1, 2001; 9(6): 355 - 364.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. W. Pagnano, G. R. Scuderi, and J. N. Insall
Tibial Osteolysis Associated with the Modular Tibial Tray of a Cemented Posterior Stabilized Total Knee Replacement : A Case Report
J. Bone Joint Surg. Am., October 1, 2001; 83(10): 1545 - 1548.
[Full Text] [PDF]


Home page
JBJSHome page
J. J. Callaghan, J. N. Insall, A. S. Greenwald, D. A Dennis, R. D. Komistek, D. W. Murray, R. B. Bourne, C. H. Rorabeck, and L. D. Dorr
Mobile-Bearing Knee Replacement : Concepts and Results*{{dagger}}
J. Bone Joint Surg. Am., July 1, 2000; 82(7): 1020 - 1020.
[Full Text]


Home page
JBJSHome page
J. J. Callaghan, M. W. Squire, D. D. Goetz, P. M. Sullivan, and R. C. Johnston
Cemented Rotating-Platform Total Knee Replacement : A Nine to Twelve-Year Follow-up Study
J. Bone Joint Surg. Am., May 1, 2000; 82(5): 705 - 705.
[Abstract] [Full Text]


Home page
JBJSHome page
T. P. SCHMALZRIED and J. J. CALLAGHAN
Current Concepts Review - Wear in Total Hip and Knee Replacements
J. Bone Joint Surg. Am., January 1, 1999; 81(1): 115 - 136.
[Full Text]


Home page
JBJSHome page
T. F. CALTON, T. K. FEHRING, W. L. GRIFFIN, and T. H. MCCOY
Failure of the Polyethylene after Bipolar Hemiarthroplasty of the Hip. A Report of Five Cases
J. Bone Joint Surg. Am., March 1, 1998; 80(3): 420 - 3.
[Full Text]


Home page
JBJSHome page
M. YAMAGUCHI, T. W. BAUER, and Y. HASHIMOTO
Three-Dimensional Analysis of Multiple Wear Vectors in Retrieved Acetabular Cups
J. Bone Joint Surg. Am., October 1, 1997; 79(10): 1539 - 44.
[Abstract] [Full Text]


Home page
JBJSHome page
P. A. DEVANE, E. J. ROBINSON, R. B. BOURNE, C. H. RORABECK, N. N. NAYAK, and J. G. HORNE
Measurement of Polyethylene Wear in Acetabular Components Inserted with and without Cement. A Randomized Trial
J. Bone Joint Surg. Am., May 1, 1997; 79(5): 682 - 89.
[Abstract] [Full Text]


Home page
JBJSHome page
M. JASTY, D. D. GOETZ, C. R. BRAGDON, K. R. LEE, A. E. HANSON, J. R. ELDER, and W. H. HARRIS
Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty. An Analysis of One Hundred and Twenty-eight Components Retrieved at Autopsy or Revision Operations
J. Bone Joint Surg. Am., March 1, 1997; 79(3): 349 - 58.
[Abstract] [Full Text]


Home page
JBJSHome page
C. J. SYCHTERZ, K. H. MOON, Y. HASHIMOTO, K. M. TEREFENKO, C. A. ENGH JR., and T. W. BAUER
Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1193 - 1200.
[Abstract] [Full Text]


Home page
JBJSHome page
K. HIRAKAWA, T. W. BAUER, B. N. STULBERG, A. H. WILDE, and M. SECIC
Characterization and Comparison of Wear Debris from Failed Total Hip Implants of Different Types
J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1235 - 43.
[Abstract] [Full Text]


Home page
JBJSHome page
D. J. ASTION, P. SALUAN, B. N. STULBERG, C. M. RIMNAC, and S. LI
The Porous-Coated Anatomic Total Hip Prosthesis: Failure of the Metal-Backed Acetabular Component
J. Bone Joint Surg. Am., May 1, 1996; 78(5): 755 - 66.
[Abstract] [Full Text]


Home page
JBJSHome page
C. SILVERTON, A. O. ROSENBERG, R. M. BARDEN, M. B. SHEINKOP, and J. O. GALANTE
The Prosthesis-Bone Interface Adjacent to Tibial Components Inserted without Cement. Clinical and Radiographic Follow-up at Nine to Twelve Years
J. Bone Joint Surg. Am., March 1, 1996; 78(3): 340 - 7.
[Abstract] [Full Text]


Home page
J Biomater ApplHome page
J. H. Dumbleton
The Clinical Significance of Wear in Total Hip and Knee Prostheses
J Biomater Appl, January 1, 1988; 3(1): 3 - 32.
[PDF]