This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, M. E.
Right arrow Articles by Humphries, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, M. E.
Right arrow Articles by Humphries, J. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 65, Issue 1 1-4, Copyright © 1983 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures

ME Miller, ML Davis, CR MacClean, JG Davis, BL Smith and JR Humphries

Because of the increased use of fluoroscopic guidance techniques in certain orthopaedic surgical procedures, surgeons and other operating-room personnel who are involved in these procedures are voicing growing concern over possible associated radiation health hazards. Using thin-layer lithium fluoride chips for thermoluminescence dosimetry, we directly measured the radiation exposure encountered by the primary surgeon during seven operative procedures that were done utilizing fluoroscopic guidance techniques. Dosimetry studies were also carried out using a tissue-equivalent phantom model to determine the directions of maximum scatter radiation. These studies indicated that the standard protective apron that is commonly worn during the use of fluoroscopy provides adequate protection to most of the body; however, the surgeon is exposed to significant levels of scatter radiation to the head, neck, and hands, Dosimetry studies showed that positioning the fluoroscopic beam vertically to the fracture site of the supine patient, with the x-ray source posterior to the patient, provided the lowest levels of scatter radiation to the surgeon in the normal working position.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
radtechHome page
J. A CHAFFINS
Radiation Protection and Procedures in the OR
Radiol. Technol., May 1, 2008; 79(5): 415 - 428.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
I. A. Tsalafoutas, V. Tsapaki, A. Kaliakmanis, S. Pneumaticos, F. Tsoronis, E. D. Koulentianos, and G. Papachristou
Estimation of radiation doses to patients and surgeons from various fluoroscopically guided orthopaedic surgeries
Radiat Prot Dosimetry, January 1, 2008; 128(1): 112 - 119.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. D. Katz
Radiation Exposure to Anesthesia Personnel: The Impact of an Electrophysiology Laboratory
Anesth. Analg., December 1, 2005; 101(6): 1725 - 1726.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
B. L. Badman, L. Rill, B. Butkovich, M. Arreola, and R. A. V. Griend
Radiation Exposure with Use of the Mini-C-Arm for Routine Orthopaedic Imaging Procedures
J. Bone Joint Surg. Am., January 1, 2005; 87(1): 13 - 17.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
M. R. Tremains, G. M. Georgiadis, and M. J. Dennis
Radiation Exposure With Use Of the Inverted-C-Arm Technique in Upper-Extremity Surgery
J. Bone Joint Surg. Am., May 1, 2001; 83(5): 674 - 678.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
B. J. Larson, J. Egbert, and E. M. Goble
Radiation Exposure During Fluoroarthroscopically Assisted Anterior Cruciate Reconstruction
Am. J. Sports Med., July 1, 1995; 23(4): 462 - 464.
[Abstract] [PDF]