This Article
Right arrow Full Text (PDF)
Right arrow Letters to the Editor: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when Letters to the Editor are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowReprints and Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, J. T.
Right arrow Articles by Crothers, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, J. T.
Right arrow Articles by Crothers, O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Technorati  
What's this?

The Journal of Bone and Joint Surgery, Vol 57, Issue 5 686-692, Copyright © 1975 by Journal of Bone and Joint Surgery, Inc


JOURNAL CONTENTS

Nailing versus prosthesis for femoral-neck fractures. A critical review of long-term results in two hundred and thirty-nine consecutive private patients

JT Johnson and O Crothers

In a follow-up study of 239 consecutive patients with fractures of the femoral neck treated by six surgeons in one hospital by Pugh nailing, Austin Moore prosthesis, or Knowles pinning, 96 per cent could be followed for a minimum of two years or until a definitve result had been reached. The incidence of unsatisfactory results was 39.3 per cent after Pugh nailing, 18.2 per cent after prosthetic replacement, and 14.2 per cent after Knowles pinning (mostly undisplaced or impacted fractures). Thirty-five unsatisfactory results following Pugh nailing were due to: aseptic necrosis which was definite in eighteen cases and probable in two; early mechanical failure in twelve cases; infection in one; and late non-union in two. Eight poor results followed prosthetic replacement and were due to erosion of the acetabulum in six and dislocation in two. The four poor results that followed Knowles pinning were due to aseptic necrosis in three and to pain, probably the results of aseptic necrosis, in another. From this study it was concluded that aseptic necrosis was more influenced by the original displacement than by the accuracy of reduction or fixation, and that in displaced femoral-neck fractures in the elderly, prosthetic replacement gave a more reliable result.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
M. Bhandari, P. J. Devereaux, M. F. Swiontkowski, P. Tornetta III, W. Obremskey, K. J. Koval, S. Nork, S. Sprague, E. H. Schemitsch, and G. H. Guyatt
Internal Fixation Compared with Arthroplasty for Displaced Fractures of the Femoral Neck: A Meta-Analysis
J. Bone Joint Surg. Am., September 1, 2003; 85(9): 1673 - 1681.
[Abstract] [Full Text] [PDF]